5,545 research outputs found

    Bilateral and Unilateral Asymmetries of Strength and Flexibility in Young Elite Sailors: Windsurfing, Optimist and Laser Classes

    Get PDF
    In sport sailing, performance is related to the sailor’s ability to maintain the stability of the boat, and the boat class determines the variables involved in such ability. In monohull-type vessels, such as the Optimist and Laser classes, the flexibility of the hip joint is a key performance factor. In the Windsurfing class, performance is determined by the strength of the flexors of the fingers and elbows. The performance of the sailor may be a ected by asymmetries in the strength and flexibility of the muscles and joints involved in technical actions. The objective of this study was to evaluate asymmetries in strength and flexibility in young sailors. Thirty-three young sailors (ten girls) from the Windsurfing, Optimist and Laser classes were assessed for manual strength and flexibility, by dynamometry and straight leg lift tests, respectively. The symmetry index and the functional asymmetry of compression force were calculated. The results showed no di erences between sailors according to gender. The sailors of the Laser class obtained the highest levels of manual strength, whereas those of the Windsurfing class showed the highest flexibility levels. The girls’ group andWindsurfing class had the highest percentage of sailors with strength asymmetry, whereas, the sailors of the Optimist class presented a greater percentage of asymmetry in flexibility. There were no di erences in upper limb strength and lower limb flexibility between the dominant and non-dominant sides

    Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: Systematic review and meta-analysis

    Get PDF
    Indexación: Scopus.The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors.https://www.degruyter.com/view/j/med.2017.12.issue-1/med-2017-0052/med-2017-0052.xm

    Grip and muscle strength dynamometry in acute burn injury: Evaluation of an updated assessment protocol

    Get PDF
    External stabilization is reported to improve reliability of hand held dynamometry, yet this has not been tested in burns. We aimed to assess the reliability of dynamometry using an external system of stabilization in people with moderate burn injury and explore construct validity of strength assessment using dynamometry. Participants were assessed on muscle and grip strength three times on each side. Assessment occurred three times per week for up to four weeks. Within session reliability was assessed using intraclass correlations calculated for within session data grouped prior to surgery, immediately after surgery and in the sub-acute phase of injury. Minimum detectable differences were also calculated. In the same timeframe categories, construct validity was explored using regression analysis incorporating burn severity and demographic characteristics. Thirty-eight participants with total burn surface area 5 – 40% were recruited. Reliability was determined to be clinically applicable for the assessment method (intraclass correlation coefficient \u3e0.75) at all phases after injury. Muscle strength was associated with sex and burn location during injury and wound healing. Burn size in the immediate period after surgery and age in the sub-acute phase of injury were also associated with muscle strength assessment results. Hand held dynamometry is a reliable assessment tool for evaluating within session muscle strength in the acute and sub-acute phase of injury in burns up to 40% total burn surface area. External stabilization may assist to eliminate reliability issues related to patient and assessor strength

    Validation of ankle strength measurements by means of a hand-held dynamometer in adult healthy subjects

    Get PDF
    Uniaxial Hand-Held Dynamometer (HHD) is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator’s ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot’s movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator’s ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot’s movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommend ed for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements

    Power grip, pinch grip, manual muscle testing or thenar atrophy - which should be assessed as a motor outcome after carpal tunnel decompression? A systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Objective assessment of motor function is frequently used to evaluate outcome after surgical treatment of carpal tunnel syndrome (CTS). However a range of outcome measures are used and there appears to be no consensus on which measure of motor function effectively captures change. The purpose of this systematic review was to identify the methods used to assess motor function in randomized controlled trials of surgical interventions for CTS. A secondary aim was to evaluate which instruments reflect clinical change and are psychometrically robust.</p> <p>Methods</p> <p>The bibliographic databases Medline, AMED and CINAHL were searched for randomized controlled trials of surgical interventions for CTS. Data on instruments used, methods of assessment and results of tests of motor function was extracted by two independent reviewers.</p> <p>Results</p> <p>Twenty-two studies were retrieved which included performance based assessments of motor function. Nineteen studies assessed power grip dynamometry, fourteen studies used both power and pinch grip dynamometry, eight used manual muscle testing and five assessed the presence or absence of thenar atrophy. Several studies used multiple tests of motor function. Two studies included both power and pinch strength and reported descriptive statistics enabling calculation of effect sizes to compare the relative responsiveness of grip and pinch strength within study samples. The study findings suggest that tip pinch is more responsive than lateral pinch or power grip up to 12 weeks following surgery for CTS.</p> <p>Conclusion</p> <p>Although used most frequently and known to be reliable, power and key pinch dynamometry are not the most valid or responsive tools for assessing motor outcome up to 12 weeks following surgery for CTS. Tip pinch dynamometry more specifically targets the thenar musculature and appears to be more responsive. Manual muscle testing, which in theory is most specific to the thenar musculature, may be more sensitive if assessed using a hand held dynamometer – the Rotterdam Intrinsic Handheld Myometer. However further research is needed to evaluate its reliability and responsiveness and establish the most efficient and psychometrically robust method of evaluating motor function following surgery for CTS.</p

    Assessment of reliability in isokinetic testing among adolescent basketball players

    Get PDF
    Background. The reproducibility of day-to-day testing of isokinetic concentric and eccentric muscular actions among adolescent basketball players aged 14 to 16 years and relationships of mean within-subject variation in two isokinetic testing sessions with chronological age, biological maturation (estimated age at peak height velocity), training experience, body size, lower-body morphology, and initial strength performance were evaluated. Material and Methods. The sample included 27 basketball players who completed replicate test sessions of 5 repetitions of reciprocal concentric and eccentric knee extensions and flexions at 60 degrees s(-1). A randomly selected subsample of 8 players completed a third testing session to confirm reliability estimates. Results. Coefficients of variation (CV) between sessions 1 and 2 ranged from 8.1% to 17.4%, and intraclass coefficients (ICCs) ranged from 0.72 to 0.89. For sessions 1 and 3, CVs ranged from 3.9% to 6.0%, and ICCs ranged from 0.95 to 0.99. The initial level of strength of eccentric knee flexion (r=-0.43) and eccentric knee extension (r=-0.42) were correlated (P<0.05) with eccentric knee extension within-variation between two sessions. Training experience (r=-0.37, P<0.05) and initial values of concentric knee flexion (r=-0.62, P<0.01) were correlated with concentric knee flexion within-subject differences. Within-subject variation of eccentric knee extension was correlated (P<0.05) with chronologic age (r=0.41), estimated age at peak height velocity (r=-0.38), body size (r=0.41 to 0.47), and leg volume (r=0.39). Conclusions. Familiarization sessions may improve the reliability of concentric and eccentric knee isokinetic strength testing at 60 s(-1) in adolescent basketball players. Age, maturity status, and training experience of young athletes should be considered when testing knee isokinetic strength at 60 degrees s(-1)

    An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for the conservative and nonpharmacological management of female pelvic floor dysfunction

    Get PDF
    There has been an increasing need for the terminology on the conservative management of female pelvic floor dysfunction to be collated in a clinically based consensus report.This Report combines the input of members and elected nominees of the Standardization and Terminology Committees of two International Organizations, the International Urogynecological Association (IUGA) and the International Continence Society (ICS), assisted at intervals by many external referees. An extensive process of nine rounds of internal and external review was developed to exhaustively examine each definition, with decision-making by collective opinion (consensus). Before opening up for comments on the webpages of ICS and IUGA, five experts from physiotherapy, neurology, urology, urogynecology, and nursing were invited to comment on the paper.A Terminology Report on the conservative management of female pelvic floor dysfunction, encompassing over 200 separate definitions, has been developed. It is clinically based, with the most common symptoms, signs, assessments, diagnoses, and treatments defined. Clarity and ease of use have been key aims to make it interpretable by practitioners and trainees in all the different specialty groups involved in female pelvic floor dysfunction. Ongoing review is not only anticipated, but will be required to keep the document updated and as widely acceptable as possible.A consensus-based terminology report for the conservative management of female pelvic floor dysfunction has been produced, aimed at being a significant aid to clinical practice and a stimulus for research

    The reliability and validity of a designed setup for the assessment of static back extensor force and endurance in older women with and without hyperkyphosis.

    Get PDF
    ObjectiveThe purpose of this study was to investigate the intra-rater reliability and validity of a designed load cell setup for the measurement of back extensor muscle force and endurance.ParticipantsThe study sample included 19 older women with hyperkyphosis, mean age 67.0&nbsp;±&nbsp;5.0&nbsp;years, and 14 older women without hyperkyphosis, mean age 63.0&nbsp;±&nbsp;6.0&nbsp;years.MethodsMaximum back extensor force and endurance were measured in a sitting position with a designed load cell setup. Tests were performed by the same examiner on two separate days within a 72-hour interval. The intra-rater reliability of the measurements was analyzed using intraclass correlation coefficient (ICC), standard errors of measurement (SEM), and minimal detectable change (MDC). The validity of the setup was determined using Pearson correlation analysis and independent t-test.ResultsUsing our designed load cell, the values of ICC indicated very high reliability of force measurement (hyperkyphosis group: 0.96, normal group: 0.97) and high reliability of endurance measurement (hyperkyphosis group: 0.82, normal group: 0.89). For all tests, the values of SEM and MDC were low in both groups. A significant correlation between two documented forces (load cell force and target force) and significant differences in the muscle force and endurance among the two groups were found.ConclusionThe measurements of static back muscle force and endurance are reliable and valid with our designed setup in older women with and without hyperkyphosis

    Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy : an intra- and interrater reliability and validity study

    Get PDF
    Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75-0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64-0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20-0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups
    corecore