30,276 research outputs found
The Application of Preconditioned Alternating Direction Method of Multipliers in Depth from Focal Stack
Post capture refocusing effect in smartphone cameras is achievable by using
focal stacks. However, the accuracy of this effect is totally dependent on the
combination of the depth layers in the stack. The accuracy of the extended
depth of field effect in this application can be improved significantly by
computing an accurate depth map which has been an open issue for decades. To
tackle this issue, in this paper, a framework is proposed based on
Preconditioned Alternating Direction Method of Multipliers (PADMM) for depth
from the focal stack and synthetic defocus application. In addition to its
ability to provide high structural accuracy and occlusion handling, the
optimization function of the proposed method can, in fact, converge faster and
better than state of the art methods. The evaluation has been done on 21 sets
of focal stacks and the optimization function has been compared against 5 other
methods. Preliminary results indicate that the proposed method has a better
performance in terms of structural accuracy and optimization in comparison to
the current state of the art methods.Comment: 15 pages, 8 figure
3D/2D Registration of Mapping Catheter Images for Arrhythmia Interventional Assistance
Radiofrequency (RF) catheter ablation has transformed treatment for
tachyarrhythmias and has become first-line therapy for some tachycardias. The
precise localization of the arrhythmogenic site and the positioning of the RF
catheter over that site are problematic: they can impair the efficiency of the
procedure and are time consuming (several hours). Electroanatomic mapping
technologies are available that enable the display of the cardiac chambers and
the relative position of ablation lesions. However, these are expensive and use
custom-made catheters. The proposed methodology makes use of standard catheters
and inexpensive technology in order to create a 3D volume of the heart chamber
affected by the arrhythmia. Further, we propose a novel method that uses a
priori 3D information of the mapping catheter in order to estimate the 3D
locations of multiple electrodes across single view C-arm images. The monoplane
algorithm is tested for feasibility on computer simulations and initial canine
data.Comment: International Journal of Computer Science Issues, IJCSI, Volume 4,
Issue 2, pp10-19, September 200
An Improved Observation Model for Super-Resolution under Affine Motion
Super-resolution (SR) techniques make use of subpixel shifts between frames
in an image sequence to yield higher-resolution images. We propose an original
observation model devoted to the case of non isometric inter-frame motion as
required, for instance, in the context of airborne imaging sensors. First, we
describe how the main observation models used in the SR literature deal with
motion, and we explain why they are not suited for non isometric motion. Then,
we propose an extension of the observation model by Elad and Feuer adapted to
affine motion. This model is based on a decomposition of affine transforms into
successive shear transforms, each one efficiently implemented by row-by-row or
column-by-column 1-D affine transforms.
We demonstrate on synthetic and real sequences that our observation model
incorporated in a SR reconstruction technique leads to better results in the
case of variable scale motions and it provides equivalent results in the case
of isometric motions
- …