2,049 research outputs found

    Quantification of Local Hemodynamic Alterations Caused by Virtual Implantation of Three Commercially Available Stents for the Treatment of Aortic Coarctation

    Get PDF
    Patients with coarctation of the aorta (CoA) are prone to morbidity including atherosclerotic plaque that has been shown to correlate with altered wall shear stress (WSS) in the descending thoracic aorta (dAo). We created the first patient-specific computational fluid dynamics (CFD) model of a CoA patient treated by Palmaz stenting to date, and compared resulting WSS distributions to those from virtual implantation of Genesis XD and modified NuMED CP stents, also commonly used for CoA. CFD models were created from magnetic resonance imaging, fluoroscopy and blood pressure data. Simulations incorporated vessel deformation, downstream vascular resistance and compliance to match measured data and generate blood flow velocity and time-averaged WSS (TAWSS) results. TAWSS was quantified longitudinally and circumferentially in the stented region and dAo. While modest differences were seen in the distal portion of the stented region, marked differences were observed downstream along the posterior dAo and depended on stent type. The Genesis XD model had the least area of TAWSS values exceeding the threshold for platelet aggregation in vitro, followed by the Palmaz and NuMED CP stents. Alterations in local blood flow patterns and WSS imparted on the dAo appear to depend on the type of stent implanted for CoA. Following confirmation in larger studies, these findings may aid pediatric interventional cardiologists in selecting the most appropriate stent for each patient, and ultimately reduce long-term morbidity following treatment for CoA by stenting

    A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models

    Get PDF
    Computational modeling is often used to quantify hemodynamic alterations induced by stenting, but frequently uses simplified device or vascular representations. Based on a series of Boolean operations, we developed an efficient and robust method for assessing the influence of current and next-generation stents on local hemodynamics and vascular biomechanics quantified by computational fluid dynamics. Stent designs were parameterized to allow easy control over design features including the number, width and circumferential or longitudinal spacing of struts, as well as the implantation diameter and overall length. The approach allowed stents to be automatically regenerated for rapid analysis of the contribution of design features to resulting hemodynamic alterations. The applicability of the method was demonstrated with patient-specific models of a stented coronary artery bifurcation and basilar trunk aneurysm constructed from medical imaging data. In the coronary bifurcation, we analyzed the hemodynamic difference between closed-cell and open-cell stent geometries. We investigated the impact of decreased strut size in stents with a constant porosity for increasing flow stasis within the stented basilar aneurysm model. These examples demonstrate the current method can be used to investigate differences in stent performance in complex vascular beds for a variety of stenting procedures and clinical scenarios

    Assessment of hemodynamic conditions in the aorta following root replacement with composite valve-conduit graft

    Get PDF
    This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced

    Pulsatile non-newtonian blood flow in image-based models of carotid bifurcation

    Get PDF
    Present hemodynamical study is motivated by the ongoing clinical research at the University Hospital in Pilsen, Czech Republic. On the basis of provided CT scans, several carotid artery models were reconstructed and used for this numerical study of pulsatile blood flow. The blood is modelled as a shear-dependent incompressible fluid, motion of which is described by the non-linear system of Navier-Stokes equations coupled with the Carreau-Yasuda model. The mathematical model is solved using in-house software based on the principle of the SIMPLE algorithm and cell-centred finite volume method (FVM) formulated for hybrid unstructured tetrahedral grids. The discussion of obtained numerical results is performed with special emphasis placed on the analysis of velocity field and distribution of main hemodynamic factors such as cycle-averaged WSS and oscillatory shear index (OSI) in areas prone to atherosclerosis

    Computational simulations demonstrate altered wall shear stress in aortic coarctation patients previously treated by resection with end-to-end anastomosis

    Get PDF
    Background.  Atherosclerotic plaque in the descending thoracic aorta (dAo) is related to altered wall shear stress (WSS) for normal patients. Resection with end-to-end anastomosis (RWEA) is the gold standard for coarctation of the aorta (CoA) repair, but may lead to altered WSS indices that contribute to morbidity. Methods.  Computational fluid dynamics (CFD) models were created from imaging and blood pressure data for control subjects and age- and gender-matched CoA patients treated by RWEA (four males, two females, 15 ± 8 years). CFD analysis incorporated downstream vascular resistance and compliance to generate blood flow velocity, time-averaged WSS (TAWSS), and oscillatory shear index (OSI) results. These indices were quantified longitudinally and circumferentially in the dAo, and several visualization methods were used to highlight regions of potential hemodynamic susceptibility. Results.  The total dAo area exposed to subnormal TAWSS and OSI was similar between groups, but several statistically significant local differences were revealed. Control subjects experienced left-handed rotating patterns of TAWSS and OSI down the dAo. TAWSS was elevated in CoA patients near the site of residual narrowings and OSI was elevated distally, particularly along the left dAo wall. Differences in WSS indices between groups were negligible more than 5 dAo diameters distal to the aortic arch. Conclusions.  Localized differences in WSS indices within the dAo of CoA patients treated by RWEA suggest that plaque may form in unique locations influenced by the surgical repair. These regions can be visualized in familiar and intuitive ways allowing clinicians to track their contribution to morbidity in longitudinal studies

    Aortic Coarctation: Recent Developments in Experimental and Computational Methods to Assess Treatments for this Simple Condition

    Get PDF
    Coarctation of the aorta (CoA) is often considered a relatively simple disease, but long-term outcomes suggest otherwise as life expectancies are decades less than in the average population and substantial morbidity often exists. What follows is an expanded version of collective work conducted by the authors\u27 and numerous collaborators that was presented at the 1st International Conference on Computational Simulation in Congenital Heart Disease pertaining to recent advances for CoA. The work begins by focusing on what is known about blood flow, pressure and indices of wall shear stress (WSS) in patients with normal vascular anatomy from both clinical imaging and the use of computational fluid dynamics (CFD) techniques. Hemodynamic alterations observed in CFD studies from untreated CoA patients and those undergoing surgical or interventional treatment are subsequently discussed. The impact of surgical approach, stent design and valve morphology are also presented for these patient populations. Finally, recent work from a representative experimental animal model of CoA that may offer insight into proposed mechanisms of long-term morbidity in CoA is presented

    Incorporating the Aortic Valve into Computational Fluid Dynamics Models using Phase-Contrast MRI and Valve Tracking

    Get PDF
    The American Heart Association states about 2% of the general population have a bicuspid aortic valve (BAV). BAVs exist in 80% of patients with aortic coarctation (CoA) and likely influences flow patterns that contribute to long-term morbidity post-surgically. BAV patients tend to have larger ascending aortic diameters, increased risk of aneurysm formation, and require surgical intervention earlier than patients with a normal aortic valve. Magnetic resonance imaging (MRI) has been used clinically to assess aortic arch morphology and blood flow in these patients. These MRI data have been used in computational fluid dynamics (CFD) studies to investigate potential adverse hemodynamics in these patients, yet few studies have attempted to characterize the impact of the aortic valve on ascending aortic hemodynamics. To address this issue, this research sought to identify the impact of aortic valve morphology on hemodynamics in the ascending aorta and determine the location where the influence is negligible. Novel tools were developed to implement aortic valve morphology into CFD models and compensate for heart motion in MRI flow measurements acquired through the aortic valve. Hemodynamic metrics such as blood flow velocity, time-averaged wall shear stress (TAWSS), and turbulent kinetic energy (TKE) induced by the valve were compared to values obtained using the current plug inflow approach. The influence of heart motion on these metrics was also investigated, resulting in the underestimation of TAWSS and TKE when heart motion was neglected. CFD simulations of CoA patients exhibiting bicuspid and tricuspid aortic valves were performed in models including the aortic sinuses and patient-specific valves. Results indicated the aortic valve impacted hemodynamics primarily in the ascending aorta, with the BAV having the greatest influence along the outer right wall of the vessel. A marked increase in TKE is present in aortic valve simulations, particularly in BAV patients. These findings suggest that future CFD studies investigating altered hemodynamics in the ascending aorta should accurately replicate aortic valve morphology. Further, aortic valve disease impacts hemodynamics in the ascending aorta that may be a predictor of the development or progression of ascending aortic dilation and possible aneurysm formation in this region

    Including Aortic Valve Morphology in Computational Fluid Dynamics Simulations: Initial Findings and Application to Aortic Coarctation

    Get PDF
    Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to develop a method to account for the AoV in CFD simulations, and quantify its impact on local hemodynamics. The method developed facilitates segmentation of the AoV, spatiotemporal interpolation of segments, and anatomic positioning of segments at the CFD model inlet. The AoV was included in CFD model examples of a normal (tricuspid AoV) and a post-surgical CoA patient (BAV). Velocity, turbulent kinetic energy (TKE), time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) results were compared to equivalent simulations using a plug inlet profile. The plug inlet greatly underestimated TKE for both examples. TAWSS differences extended throughout the thoracic aorta for the CoA BAV, but were limited to the arch for the normal example. OSI differences existed mainly in the ascending aorta for both cases. The impact of AoV can now be included with CFD simulations to identify regions of deleterious hemodynamics thereby advancing simulations of the thoracic aorta one step closer to reality

    Patient-Specific Modeling of Altered Coronary Artery Hemodynamics to Predict Morbidity in Patients with Anomalous Origin of a Coronary Artery

    Get PDF
    Anomalous aortic origin of a coronary artery (AAOCA) is a condition where a coronary artery arises from the opposite aortic sinus, often with acute angle of origin (AO). AAOCA is associated with ischemia.1 This is especially concerning when the anomalous coronary artery takes an intramural course within the aortic wall, creating the potential for distortion or compression. Unroofing surgery replaces a restrictive ostium and intramural segment with a large ostium from the appropriate sinus and aims to create a less acute AO. Although these anatomical features may alter coronary artery blood flow patterns, hemodynamic indices such as time averaged wall shear stress (TAWSS), oscillatory shear index (OSI) and fractional flow reserve (FFR) that impact a patient’s future risk for ischemia and morbidity 2–6 remain largely unexplored. We hypothesized that morphology of the anomalous coronary artery has a significant impact on local hemodynamics of AAOCA and aimed to 1) characterize hemodynamic alterations in AAOCA by patient-specific simulation of patients pre-operative and post-unroofing using advanced coronary artery boundary conditions, 2) assess the impact of AO on the severity of hemodynamic alterations, and 3) characterize the hemodynamic effect of proximal narrowing of the anomalous artery and hyperemic resistance of the downstream vasculature (HMR) on FFR. Findings from Aim 1 suggested that different flow patterns exist natively between right and left coronary arteries, a reduction in TAWSS is observed post-unroofing, and that unroofing may normalize TAWSS but with variance related to the AO. Data from Aim 2 indicated that AO alters TAWSS and OSI in simulations run from a patient-specific model with virtually rotated AOs. The arterial wall experienced lower TAWSS for more acute AO near the ostium. Distal to the ostium, arterial wall experienced higher TAWSS for more acute AO. Findings from Aim 3 showed that for a given narrowing, higher HMR resulted in higher FFR thereby mimicking the interaction of the upstream and downstream micro-vasculature resistance to regulate FFR for the first time using computational models of AAOCA. Virtual manipulation of the anomalous artery provided a direct comparison for the effect of the anatomic high-risk features. Collectively, these results serve as the foundation for larger studies of AAOCA that could correlate hemodynamics with outcomes for risk stratification and surgical evaluation
    corecore