    Towards inline spatially resolved temperature sensing in thermal ablation with chirped fiber Bragg grating

    Get PDF
    We investigate the theory and feasibility of an in-line spatially resolved temperature sensor, suitable for thermal ablation monitoring. The sensor is based o a chirped fiber Bragg grating (CFBG). The CFBG is modelled as a chain of Bragg gratings, each sensitive to local temperature variations. By using a combination of iterative and statistical optimization techniques, it is possible to use demodulate the CFBG, in case of a Gaussian-like spatial temperature profile. A feasibility test based on CFBG simulation shows that the CFBG returns error <1 mm on cells damage threshold spatial estimation and good noise resilience

    A Fiber Optic Probe for Tumor Laser Ablation with Integrated Temperature Measurement Capability

    Get PDF
    The paper presents the characterization results of a new all-optical applicator for improved tumor laser ablation treatments that features customized irradiation pattern and builtin temperature sensors. The probe exploits a double cladding optical fiber to integrate some Bragg gratings acting as temperature sensing elements in the core, while guiding the high power beam used for the ablation in the inner cladding. The assessment of the probe behavior has been conducted in two steps: first, with an agar gel phantom to characterize the irradiation pattern and to validate the Bragg grating based measurement setup in comparison with a thermographic camera; then, simulating actual treatments using an ex-vivo animal liver

    Distributed 2D temperature sensing during nanoparticles assisted laser ablation by means of high-scattering fiber sensors

    Get PDF
    The high demand in effective and minimally invasive cancer treatments, namely thermal ablation, leads to the demand for real-time multi-dimensional thermometry to evaluate the treatment effectiveness, which can be also assisted by the use of nanoparticles. We report the results of 20-nm gold and magnetic iron oxide nanoparticles-assisted laser ablation on a porcine liver phantom. The experimental set-up consisting of high-scattering nanoparticle-doped fibers was operated by means of a scattering–level multiplexing arrangement and interrogated via optical backscattered reflectometry, together with a solid-state laser diode operating at 980 nm. The multiplexed 2-dimensional fiber arrangement based on nanoparticle-doped fibers allowed an accurate superficial thermal map detected in real-time

    Estimation of porcine pancreas optical properties in the 600–1100&nbsp;nm wavelength range for light-based therapies

    Get PDF
    This work reports the optical properties of porcine pancreatic tissue in the broad wavelength range of 600–1100 nm. Absorption and reduced scattering coefficients (µ(a) and µ(s)′) of the ex vivo pancreas were obtained by means of Time-domain Diffuse Optical Spectroscopy. We have investigated different experimental conditions—including compression, repositioning, spatial sampling, temporal stability—the effect of the freezing procedure (fresh vs frozen-thawed pancreas), and finally inter-sample variability. Good repeatability under different experimental conditions was obtained (median coefficient of variation less than 8% and ~ 16% for µ(a) and µ(s)′, respectively). Freezing–thawing the samples caused an irreversible threefold reduction of µ(s)′ and no effect on µ(a). The absorption and reduced scattering spectra averaged over different samples were in the range of 0.12–0.74 cm(−1) and 12–21 cm(−1) with an inter-sample variation of ~ 10% and ~ 40% for µ(a) and µ(s)′, respectively. The calculated effective transport coefficient (µ(eff)) for fresh pancreatic tissue shows that regions between 800–900 nm and 1050–1100 nm are similar and offer the lowest tissue attenuation in the considered range (i.e., µ(eff) ranging from 2.4 to 2.7 cm(−1)). These data, describing specific light-pancreas interactions in the therapeutic optical window for the first time, provide pivotal information for planning of light-based thermotherapies (e.g., laser ablation) and instruction of light transport models for biophotonic applications involving this organ

    Characterization of susceptibility artifacts in magnetic resonance thermometry images during laser interstitial thermal therapy: dimension analysis and temperature error estimation

    Get PDF
    Objective: Laser interstitial thermal therapy (LITT) is a minimally invasive procedure used to treat a lesion through light irradiation and consequent temperature increase. Magnetic Resonance Thermometry Imaging (MRTI) provides a multidimensional measurement of the temperature inside the target thus enabling accurate monitoring of the zone of damage during the procedure. In proton resonance frequency shift-based thermometry, artifacts in the images may strongly interfere with the estimated temperature maps. In our work, after noticing the formation of the dipolar-behavior artifact linkable to magnetic susceptibility changes during in vivo LITT, an investigation of susceptibility artifacts in tissue-mimicking phantoms was implemented. Approach: The artifact was characterized: (i) by measuring the area and total volume of error regions and their evolution during the treatment; and (ii) by comparison with temperature reference provided by three temperature sensing needles. Lastly, a strategy to avoid artifacts formation was devised by using the temperature-sensing needles to implement a temperature-controlled LITT. Main results: The artifact appearance was associated with gas bubble formation and with unwanted treatment effects producing magnetic susceptibility changes when 2 W laser power was set. The analysis of the artifact's dimension demonstrated that in the sagittal plane the dipolar-shape artifact may consistently spread following the temperature trend until reaching a volume 8 times bigger than the ablated one. Also, the artifact shape is quite symmetric with respect to the laser tip. An absolute temperature error showing a negative Gaussian profile in the area of susceptibility artifact with values up to 64.4 °C was estimated. Conversely, a maximum error of 2.8 °C is measured in the area not-affected by artifacts and far from the applicator tip. Finally, by regulating laser power, susceptibility artifacts formation was avoided, and appreciable thermal damage was induced. Significance: Such findings may help in improving the MRTI-based guidance of thermal therapies

    Feedback-controlled laser ablation for cancer treatment: comparison of On-Off and PID control strategies

    Get PDF
    : Laser ablation is a rising technique used to induce a localized temperature increment for tumor ablation. The outcomes of the therapy depend on the tissue thermal history. Monitoring devices help to assess the tissue thermal response, and their combination with a control strategy can be used to promptly address unexpected temperature changes and thus reduce unwanted thermal effects. In this application, numerical simulations can drive the selection of the laser control settings (i.e., laser power and gain parameters) and allow evaluating the thermal effects of the control strategies. In this study, the influence of different control strategies (On-Off and PID-based controls) is quantified considering the treatment time and the thermal effect on the tissue. Finite element model-based simulations were implemented to model the laser-tissue interaction, the heat-transfer, and the consequent thermal damage in liver tissue with tumor. The laser power was modulated based on the temperature feedback provided within the tumor safety margin. Results show that the chosen control strategy does not have a major influence on the extent of thermal damage but on the treatment duration; the percentage of necrosis within the tumor domain is 100% with both strategies, while the treatment duration is 630 s and 786 s for On-Off and PID, respectively. The choice of the control strategy is a trade-off between treatment duration and unwanted temperature overshoot during closed-loop laser ablation. Clinical Relevance-This work establishes that different temperature-based control of the laser ablation procedure does not have a major influence on the extent of thermal damage but on the duration of treatment

    Multipoint temperature monitoring of microwave thermal ablation in bones through fiber bragg grating sensor arrays

    Get PDF
    Bones are a frequent site of metastases that cause intolerable cancer-related pain in 90% of patients, making their quality of life poor. In this scenario, being able to treat bone oncology patients by means of minimally invasive techniques can be crucial to avoid surgery-related risks and decrease hospitalization times. The use of microwave ablation (MWA) is gaining broad clinical acceptance to treat bone tumors. It is worth investigating temperature variations in bone tissue undergoing MWA because the clinical outcomes can be inferred from this parameter. Several feasibility studies have been performed, but an experimental analysis of the temperature trends reached into the bone during the MWA has not yet been assessed. In this work, a multi-point temperature study along the bone structure during such treatment is presented. The study has been carried out on ex vivo bovine femur and tibia, subjected to MWA. An overall of 40 measurement points covering a large sensing area was obtained for each configuration. Temperature monitoring was performed by using 40 fiber Bragg grating (FBGs) sensors (four arrays each housing 10 FBGs), inserted into the bones at specific distances to the microwave antenna. As result, the ability of this experimental multi-point monitoring approach in tracking temperature variations within bone tissue during MWA treatments was shown. This study lays the foundations for the design of a novel approach to study the effects of MWA on bone tumors. As consequence, the MWA treatment settings could be optimized in order to maximize the treatment effects of such a promising clinical application, but also customized for the specific tumor and patient

    Fiber bragg gratings for medical applications and future challenges: A review

    Get PDF
    In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of next-generation medical devices and healthcare system