457 research outputs found
Simultaneous use of Individual and Joint Regularization Terms in Compressive Sensing: Joint Reconstruction of Multi-Channel Multi-Contrast MRI Acquisitions
Purpose: A time-efficient strategy to acquire high-quality multi-contrast
images is to reconstruct undersampled data with joint regularization terms that
leverage common information across contrasts. However, these terms can cause
leakage of uncommon features among contrasts, compromising diagnostic utility.
The goal of this study is to develop a compressive sensing method for
multi-channel multi-contrast magnetic resonance imaging (MRI) that optimally
utilizes shared information while preventing feature leakage.
Theory: Joint regularization terms group sparsity and colour total variation
are used to exploit common features across images while individual sparsity and
total variation are also used to prevent leakage of distinct features across
contrasts. The multi-channel multi-contrast reconstruction problem is solved
via a fast algorithm based on Alternating Direction Method of Multipliers.
Methods: The proposed method is compared against using only individual and
only joint regularization terms in reconstruction. Comparisons were performed
on single-channel simulated and multi-channel in-vivo datasets in terms of
reconstruction quality and neuroradiologist reader scores.
Results: The proposed method demonstrates rapid convergence and improved
image quality for both simulated and in-vivo datasets. Furthermore, while
reconstructions that solely use joint regularization terms are prone to
leakage-of-features, the proposed method reliably avoids leakage via
simultaneous use of joint and individual terms.
Conclusion: The proposed compressive sensing method performs fast
reconstruction of multi-channel multi-contrast MRI data with improved image
quality. It offers reliability against feature leakage in joint
reconstructions, thereby holding great promise for clinical use.Comment: 13 pages, 13 figures. Submitted for possible publicatio
First order algorithms in variational image processing
Variational methods in imaging are nowadays developing towards a quite
universal and flexible tool, allowing for highly successful approaches on tasks
like denoising, deblurring, inpainting, segmentation, super-resolution,
disparity, and optical flow estimation. The overall structure of such
approaches is of the form ; where the functional is a data fidelity term also
depending on some input data and measuring the deviation of from such
and is a regularization functional. Moreover is a (often linear)
forward operator modeling the dependence of data on an underlying image, and
is a positive regularization parameter. While is often
smooth and (strictly) convex, the current practice almost exclusively uses
nonsmooth regularization functionals. The majority of successful techniques is
using nonsmooth and convex functionals like the total variation and
generalizations thereof or -norms of coefficients arising from scalar
products with some frame system. The efficient solution of such variational
problems in imaging demands for appropriate algorithms. Taking into account the
specific structure as a sum of two very different terms to be minimized,
splitting algorithms are a quite canonical choice. Consequently this field has
revived the interest in techniques like operator splittings or augmented
Lagrangians. Here we shall provide an overview of methods currently developed
and recent results as well as some computational studies providing a comparison
of different methods and also illustrating their success in applications.Comment: 60 pages, 33 figure
Low-rank and sparse reconstruction in dynamic magnetic resonance imaging via proximal splitting methods
Dynamic magnetic resonance imaging (MRI) consists of collecting multiple MR images in time, resulting in a spatio-temporal signal. However, MRI intrinsically suffers from long acquisition times due to various constraints. This limits the full potential of dynamic MR imaging, such as obtaining high spatial and temporal resolutions which are crucial to observe dynamic phenomena. This dissertation addresses the problem of the reconstruction of dynamic MR images from a limited amount of samples arising from a nuclear magnetic resonance experiment. The term limited can be explained by the approach taken in this thesis to speed up scan time, which is based on violating the Nyquist criterion by skipping measurements that would be normally acquired in a standard MRI procedure. The resulting problem can be classified in the general framework of linear ill-posed inverse problems. This thesis shows how low-dimensional signal models, specifically lowrank and sparsity, can help in the reconstruction of dynamic images from partial measurements. The use of these models are justified by significant developments in signal recovery techniques from partial data that have emerged in recent years in signal processing. The major contributions of this thesis are the development and characterisation of fast and efficient computational tools using convex low-rank and sparse constraints via proximal gradient methods, the development and characterisation of a novel joint reconstruction–separation method via the low-rank plus sparse matrix decomposition technique, and the development and characterisation of low-rank based recovery methods in the context of dynamic parallel MRI. Finally, an additional contribution of this thesis is to formulate the various MR image reconstruction problems in the context of convex optimisation to develop algorithms based on proximal splitting methods
PEAR: PEriodic And fixed Rank separation for fast fMRI
In functional MRI (fMRI), faster acquisition via undersampling of data can
improve the spatial-temporal resolution trade-off and increase statistical
robustness through increased degrees-of-freedom. High quality reconstruction of
fMRI data from undersampled measurements requires proper modeling of the data.
We present an fMRI reconstruction approach based on modeling the fMRI signal as
a sum of periodic and fixed rank components, for improved reconstruction from
undersampled measurements. We decompose the fMRI signal into a component which
a has fixed rank and a component consisting of a sum of periodic signals which
is sparse in the temporal Fourier domain. Data reconstruction is performed by
solving a constrained problem that enforces a fixed, moderate rank on one of
the components, and a limited number of temporal frequencies on the other. Our
approach is coined PEAR - PEriodic And fixed Rank separation for fast fMRI.
Experimental results include purely synthetic simulation, a simulation with
real timecourses and retrospective undersampling of a real fMRI dataset.
Evaluation was performed both quantitatively and visually versus ground truth,
comparing PEAR to two additional recent methods for fMRI reconstruction from
undersampled measurements. Results demonstrate PEAR's improvement in estimating
the timecourses and activation maps versus the methods compared against at
acceleration ratios of R=8,16 (for simulated data) and R=6.66,10 (for real
data). PEAR results in reconstruction with higher fidelity than when using a
fixed-rank based model or a conventional Low-rank+Sparse algorithm. We have
shown that splitting the functional information between the components leads to
better modeling of fMRI, over state-of-the-art methods
- …