73,539 research outputs found

    Unbalanced load flow with hybrid wavelet transform and support vector machine based Error-Correcting Output Codes for power quality disturbances classification including wind energy

    Get PDF
    Purpose. The most common methods to designa multiclass classification consist to determine a set of binary classifiers and to combine them. In this paper support vector machine with Error-Correcting Output Codes (ECOC-SVM) classifier is proposed to classify and characterize the power qualitydisturbances such as harmonic distortion,voltage sag, and voltage swell include wind farms generator in power transmission systems. Firstly three phases unbalanced load flow analysis is executed to calculate difference electric network characteristics, levels of voltage, active and reactive power. After, discrete wavelet transform is combined with the probabilistic ECOC-SVM model to construct the classifier. Finally, the ECOC-SVM classifies and identifies the disturbance type according tothe energy deviation of the discrete wavelet transform. The proposedmethod gives satisfactory accuracy with 99.2% compared with well known methods and shows that each power quality disturbances has specific deviations from the pure sinusoidal waveform,this is good at recognizing and specifies the type of disturbance generated from the wind power generator.Наиболее распространенные методы построения мультиклассовой классификации заключаются в определении набора двоичных классификаторов и их объединении. В данной статье предложена машина опорных векторов с классификатором выходных кодов исправления ошибок(ECOC-SVM) с целью классифицировать и характеризовать такие нарушения качества электроэнергии, как гармонические искажения, падение напряжения и скачок напряжения, включая генератор ветровых электростанций в системах передачи электроэнергии. Сначала выполняется анализ потока несимметричной нагрузки трех фаз для расчета разностных характеристик электрической сети, уровней напряжения, активной и реактивной мощности. После этого дискретное вейвлет-преобразование объединяется с вероятностной моделью ECOC-SVM для построения классификатора. Наконец, ECOC-SVM классифицирует и идентифицирует тип возмущения в соответствии с отклонением энергии дискретного вейвлет-преобразования. Предложенный метод дает удовлетворительную точность 99,2% по сравнению с хорошо известными методами и показывает, что каждое нарушение качества электроэнергии имеет определенные отклонения от чисто синусоидальной формы волны, что способствует распознаванию и определению типа возмущения, генерируемого ветровым генератором

    Submodular Load Clustering with Robust Principal Component Analysis

    Full text link
    Traditional load analysis is facing challenges with the new electricity usage patterns due to demand response as well as increasing deployment of distributed generations, including photovoltaics (PV), electric vehicles (EV), and energy storage systems (ESS). At the transmission system, despite of irregular load behaviors at different areas, highly aggregated load shapes still share similar characteristics. Load clustering is to discover such intrinsic patterns and provide useful information to other load applications, such as load forecasting and load modeling. This paper proposes an efficient submodular load clustering method for transmission-level load areas. Robust principal component analysis (R-PCA) firstly decomposes the annual load profiles into low-rank components and sparse components to extract key features. A novel submodular cluster center selection technique is then applied to determine the optimal cluster centers through constructed similarity graph. Following the selection results, load areas are efficiently assigned to different clusters for further load analysis and applications. Numerical results obtained from PJM load demonstrate the effectiveness of the proposed approach.Comment: Accepted by 2019 IEEE PES General Meeting, Atlanta, G

    Program latihan industri di Kolej Universiti Teknologi Tun Hussein Onn : kajian terhadap perlaksanaan sistem penilaian

    Get PDF
    Kajian yang dijalankan adalah bertajuk "Program Lalilian lndustri Di Kolej Universiti Teknologi Tun Hussein Onn : Kajian Terhadap Perlaksanaan Sistem Penilaian". Sampel terdin daripada 6 orang pakar serta 63 orang pelajar yang terlibat dalam latihan industri. Maklumat yang diperolehi berdasarkan kaedah kualitatif dan kuantitatif Data dianalisis untuk meninjau kaedah penilaian yang dijalankan dan seterusnya memastikan apakali sistem penilaian yang perlu diperbaiki. Secara keseluruhannya, kebanyakan responden berpendapat bahawa sistem penilaian yang sedia ada adalah perlu diperbaki dan disistematikkan selaras dengan ISO 9000 : 2001. Berdasarkan daripada keputusan yang diperolehi dan bimbingnan pakar dari Unit Latihan lndustri KUiTTHO, maka satu "Buku Panduan Penilaian Latihan lndustri" dihasilkan dengan panduan yang ringkas dan lampiran borang-borang yang telah diperbaiki dan diubahsuai. Diharapkan produk mi dapat digunakan untuk masa-masa akan datang

    Fault Location in Power Distribution Systems via Deep Graph Convolutional Networks

    Full text link
    This paper develops a novel graph convolutional network (GCN) framework for fault location in power distribution networks. The proposed approach integrates multiple measurements at different buses while taking system topology into account. The effectiveness of the GCN model is corroborated by the IEEE 123 bus benchmark system. Simulation results show that the GCN model significantly outperforms other widely-used machine learning schemes with very high fault location accuracy. In addition, the proposed approach is robust to measurement noise and data loss errors. Data visualization results of two competing neural networks are presented to explore the mechanism of GCN's superior performance. A data augmentation procedure is proposed to increase the robustness of the model under various levels of noise and data loss errors. Further experiments show that the model can adapt to topology changes of distribution networks and perform well with a limited number of measured buses.Comment: Accepcted by IEEE Journal on Selected Areas in Communicatio

    High Voltage Insulator Surface Evaluation Using Image Processing

    Full text link
    High voltage insulators are widely deployed in power systems to isolate the live- and dead-part of overhead lines as well as to support the power line conductors mechanically. Permanent, secure and safe operation of power transmission lines require that the high voltage insulators are inspected and monitor, regularly. Severe environment conditions will influence insulator surface and change creepage distance. Consequently, power utilities and transmission companies face significant problem in operation due to insulator damage or contamination. In this study, a new technique is developed for real-time inspection of insulator and estimating the snow, ice and water over the insulator surface which can be a potential risk of operation breakdown. To examine the proposed system, practical experiment is conducted using ceramic insulator for capturing the images with snow, ice and wet surface conditions. Gabor and Standard deviation filters are utilized for image feature extraction. The best achieved recognition accuracy rate was 87% using statistical approach the Standard deviation.Comment: 2017 International Symposium on Electrical Insulating Materials, September 12-15, 201

    Diagnosis of Combination Faults in a Planetary Gearbox using a Modulation Signal Bispectrum based Sideband Estimator

    Get PDF
    This paper presents a novel method for diagnosing combination faults in planetary gearboxes. Vibration signals measured on the gearbox housing exhibit complicated characteristics because of multiple modulations of concurrent excitation sources, signal paths and noise. To separate these modulations accurately, a modulation signal bispectrum based sideband estimator (MSB-SE) developed recently is used to achieve a sparse representation for the complicated signal contents, which allows effective enhancement of various sidebands for accurate diagnostic information. Applying the proposed method to diagnose an industrial planetary gearbox which coexists both bearing faults and gear faults shows that the different severities of the faults can be separated reliably under different load conditions, confirming the superior performance of this MSB-SE based diagnosis scheme
    corecore