3,808 research outputs found

    Aggressive Surveillance Is Needed to Detect Endoleaks and Junctional Separation between Device Components after Zenith Fenestrated Aortic Reconstruction

    Get PDF
    Background Junctional separation and resulting type IIIa endoleak is a well-known problem after EVAR (endovascular aneurysm repair). This complication results in sac pressurization, enlargement, and eventual rupture. In this manuscript, we review the incidence of this late finding in our experience with the Cook Zenith fenestrated endoprosthesis (ZFEN, Bloomington, IN). Methods A retrospective review was performed of a prospectively maintained institutional ZFEN fenestrated EVAR database capturing all ZFENs implanted at a large-volume, academic hospital system. Patients who experienced junctional separation between the fenestrated main body and distal bifurcated graft (with or without type IIIa endoleak) at any time after initial endoprosthesis implantation were subject to further evaluation of imaging and medical records to abstract clinical courses. Results In 110 ZFENs implanted from October 2012 to December 2017 followed for a mean of 1.5 years, we observed a 4.5% and 2.7% incidence of clinically significant junctional separation and type IIIa endoleak, respectively. Junctional separation was directly related to concurrent type Ib endoleak in all 5 patients. Three patients presented with sac enlargement. One patient did not demonstrate any evidence of clinically significant endoleak and had a decreasing sac size during follow-up imaging. The mean time to diagnosis of modular separation in these patients was 40 months. Junctional separation was captured in surveillance in 2 patients and reintervened upon before manifestation of endoleak. However, the remaining 3 patients completed modular separation resulting in rupture and emergent intervention in 2 and an aortic-related mortality in the other. Conclusions Junctional separation between the fenestrated main and distal bifurcated body with the potential for type IIIa endoleak is an established complication associated with the ZFEN platform. Therefore, we advocate for maximizing aortic overlap during the index procedure followed by aggressive surveillance and treatment of stent overlap loss captured on imaging

    Spontaneous sealing of a type Ia endoleak after ovation stent graft implantation in a patient with on-label aortic neck anatomy

    Get PDF
    We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings

    Nellix endovascular aortic sealing endoprosthesis late explantation for concomitant type I endoleak and stent frames proximal caudal migration

    Get PDF
    Endovascular aneurysm sealing (EVAS) using the Nellixâ„¢ System was introduced in clinical practice with the aim of reducing the incidence of complications such as migration, endoleaks, and reinterventions after conventional endovascular aneurysm repair (EVAR). Although, initial efficacy data on this device have been encouraging, EVAS has also demonstrated to undergo adverse events. Herein, we report a case of Nellix graft explant due to endobags shrinkage after air bubble reabsorption leading to proximal type I A endoleak and stent migration. The focus of this article is on the importance of a more assiduous surveillance of this new device, in particular in those cases with air into the endobags immediately after the procedure; this surveillance should be aimed to timely identify complications which can otherwise lead to consequences that require open conversion

    Long-term results of iliac aneurysm repair with iliac branched endograft. A 5-year experience on 100 consecutive cases

    Get PDF
    Background: Iliac branch device (IBD) technique has been introduced as an appealing and effective solution to avoid complications occurring during repair of aorto-iliac aneurysm with extensive iliac involvement. Nevertheless, no large series with long-term follow-up of IBD are available. The aim of this study was to analyse safety and long-term efficacy of IBD in a consecutive series of patients.Methods: Between 2006 and 2011, 100 consecutive patients were enrolled in a prospective database on IBD. Indications included unilateral or bilateral common iliac artery aneurysms combined or not with abdominal aneurysms. Patients were routinely followed up with computed tomography. Data were reported according to the Kaplan-Meier method.Results: There were 96 males, mean age 74.1 years. Preoperative median common iliac aneurysm diameter was 40 mm (interquartile range (IQR): 35-44 mm). Sixty-seven patients had abdominal aortic aneurysm >35 mm (IQR: 40-57 mm) associated with iliac aneurysm. Eleven patients presented hypogastric aneurysm. Twelve patients underwent isolated iliac repair with IBD and 88 patients received associated endovascular aortic repair. Periprocedural technical success rate was 95%, with no mortality. Two patients experienced external iliac occlusion in the first month. At a median follow-up of 21 months (range 1-60) aneurysm growth >3 mm was detected in four iliac (4%) arteries. Iliac endoleak (one type III and two distal type I) developed in three patients and buttock claudication in four patients. Estimated patency rate of internal iliac branch was 91.4% at 1 and 5 years. Freedom from any reintervention rate was 90% at 1 year and 81.4% at 5 years. No late ruptures occurred.Conclusions: Long-term results show that IBD use can ensure persistent iliac aneurysm exclusion at 5 years, with low risk of reintervention. This technique can be considered as a first endovascular option in patients with extensive iliac aneurysm disease and favourable anatomy. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved

    CEUS: What is its role in abdominal aortic diseases?

    Get PDF

    Combined transbrachial and transfemoral strategy to deploy an iliac branch endoprosthesis in the setting of a pre-existing endovascular aortic aneurysm repair

    Get PDF
    This article describes brachial access to position a long sheath in the abdominal aorta in conjunction with a large caliber sheath via the femoral artery ipsilateral to the target site to deliver a 0.018 bodyfloss wire. This bodyfloss wire is inserted into the precannulation port of the iliac branch endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz), which is then advanced from the groin. Once the bifurcated device is deployed, hypogastric access and stenting is achieved from the upper extremity. This technique is an alternative to safely extend the distal seal while preserving the hypogastric artery and has the advantage of limited iliac bifurcation manipulation

    Endovascular treatment of visceral artery aneurysms and pseudoaneurysms with stent-graft: Analysis of immediate and long-term results

    Get PDF
    The aim of this study is to analyze the safety and efficacy of stent-graft endovascular treatment for visceral artery aneurysms and pseudoaneurysms. METHODS: Multicentric retrospective series of patients with visceral aneurysms and pseudoaneurysms treated by means of stent graft. The following variables were analyzed: Age, sex, type of lesion (aneurysms/pseudoaneurysms), localization, rate of success, intraprocedural and long term complication rate (SIR classification). Follow-up was performed under clinical and radiological assessment. RESULTS: Twenty-five patients (16 men), with a mean age of 59 (range 27-79), were treated. The indication was aneurysm in 19 patients and pseudoaneurysms in 6. The localizations were: splenic artery (12), hepatic artery (5), renal artery (4), celiac trunk (3) and gastroduodenal artery (1). Successful treatment rate was 96% (24/25 patients). Intraprocedural complication rate was 12% (4% major; 8% minor). Complete occlusion was demonstrated during follow up (mean 33 months, range 6-72) in the 24 patients with technical success. Two stent migrations (2/24; 8%) and 4stent thrombosis (4/24; 16%) were detected. Mortality rate was 0%. CONCLUSION: In our study, stent-graft endovascular treatment of visceral aneurysmns and pseudoaneurysms has demonstrated to be safe and is effective in the long-term in both elective and emergent cases, with a high rate of successful treatment and a low complication rate

    Hybrid debranching and TEVAR of the aortic arch off-pump, in re-do patients with complicated chronic type-A aortic dissections : a critical report

    Get PDF
    Background: Patients suffering from acute type A aortic dissection undergo replacement of the ascending aorta, the proximal hemiarch or complete aortic arch, depending on the extent of the individual pathology. In a subset of these treated patients, secondary pathologies of the distal anastomosis or the remaining distal part of the aorta occur. The treatment of these pathologies is challenging, requiring major surgical re-do procedures with aortic arch replacement under extracorporeal circulation and hypothermic circulatory arrest. Methods: We report our experience of five patients with complex aortic pathologies after previous aortic surgery treated with a single stage re-do hybrid procedure, consisting of bypass grafting of the supraaortic branches off-pump, stent graft placement for endovascular aortic repair (TEVAR) and surgical debranching of the aortic arch. Results: In all patients the surgical vascular grafts and stent grafts were deployed successfully, there were no intraoperative deaths. Four out of five patients were discharged from hospital in good clinical condition. One patient died postoperatively due to cardiac tamponade. In one patient a type I endoleak persisted leading to occlusion of a bypass branch requiring surgical revision at one year after debranching. Conclusion: We discuss the prerequisites, all steps and potential pitfalls of this hybrid aortic arch replacement. The current procedure avoids cardiopulmonary bypass and circulatory arrest, which may benefit early patient outcome; however, patient and device selection plays a key role for immediate success and midterm outcomes. In addition, precise procedural planning and development of customized stents may help to develop this procedure into a true alternative for conventional aortic arch replacement
    • …
    corecore