    Cost and losses associated with offshore wind farm collection networks which centralise the turbine power electronic converters

    Get PDF
    Costs and losses have been calculated for several different network topologies, which centralise the turbine power electronic converters, in order to improve access for maintenance. These are divided into star topologies, where each turbine is connected individually to its own converter on a platform housing many converters, and cluster topologies, where multiple turbines are connected through a single large converter. Both AC and DC topologies were considered, along with standard string topologies for comparison. Star and cluster topologies were both found to have higher costs and losses than the string topology. In the case of the star topology, this is due to the longer cable length and higher component count. In the case of the cluster topology, this is due to the reduced energy capture from controlling turbine speeds in clusters rather than individually. DC topologies were generally found to have a lower cost and loss than AC, but the fact that the converters are not commercially available makes this advantage less certain

    Switching overvoltages in offshore wind power grids

    Get PDF

    Structural health monitoring of offshore wind turbines: A review through the Statistical Pattern Recognition Paradigm

    Get PDF
    Offshore Wind has become the most profitable renewable energy source due to the remarkable development it has experienced in Europe over the last decade. In this paper, a review of Structural Health Monitoring Systems (SHMS) for offshore wind turbines (OWT) has been carried out considering the topic as a Statistical Pattern Recognition problem. Therefore, each one of the stages of this paradigm has been reviewed focusing on OWT application. These stages are: Operational Evaluation; Data Acquisition, Normalization and Cleansing; Feature Extraction and Information Condensation; and Statistical Model Development. It is expected that optimizing each stage, SHMS can contribute to the development of efficient Condition-Based Maintenance Strategies. Optimizing this strategy will help reduce labor costs of OWTs׳ inspection, avoid unnecessary maintenance, identify design weaknesses before failure, improve the availability of power production while preventing wind turbines׳ overloading, therefore, maximizing the investments׳ return. In the forthcoming years, a growing interest in SHM technologies for OWT is expected, enhancing the potential of offshore wind farm deployments further offshore. Increasing efficiency in operational management will contribute towards achieving UK׳s 2020 and 2050 targets, through ultimately reducing the Levelised Cost of Energy (LCOE)

    The adequacy of the present practice in dynamic aggregated modelling of wind farm systems

    Get PDF
    Large offshore wind farms are usually composed of several hundred individual wind turbines, each turbine having its own complex set of dynamics. The analysis of the dynamic interaction between wind turbine generators (WTG), interconnecting ac cables, and voltage source converter (VSC) based High Voltage DC (HVDC) system is difficult because of the complexity and the scale of the entire system. The detailed modelling and modal analysis of a representative wind farm system reveal the presence of several critical resonant modes within the system. Several of these modes have frequencies close to harmonics of the power system frequency with poor damping. From a computational perspective the aggregation of the physical model is necessary in order to reduce the degree of complexity to a practical level. This paper focuses on the present practices of the aggregation of the WTGs and the collection system, and their influence on the damping and frequency characteristics of the critical oscillatory modes. The effect of aggregation on the critical modes are discussed using modal analysis and dynamic simulation. The adequacy of aggregation method is discussed

    Fault analysis and protection for wind power generation systems

    Get PDF
    Wind power is growing rapidly around the world as a means of dealing with the world energy shortage and associated environmental problems. Ambitious plans concerning renewable energy applications around European countries require a reliable yet economic system to generate, collect and transmit electrical power from renewable resources. In populous Europe, collective offshore large-scale wind farms are efficient and have the potential to reach this sustainable goal. This means that an even more reliable collection and transmission system is sought. However, this relatively new area of offshore wind power generation lacks systematic fault transient analysis and operational experience to enhance further development. At the same time, appropriate fault protection schemes are required. This thesis focuses on the analysis of fault conditions and investigates effective fault ride-through and protection schemes in the electrical systems of wind farms, for both small-scale land and large-scale offshore systems. Two variable-speed generation systems are considered: doubly-fed induction generators (DFIGs) and permanent magnet synchronous generators (PMSGs) because of their popularity nowadays for wind turbines scaling to several-MW systems. The main content of the thesis is as follows. The protection issues of DFIGs are discussed, with a novel protection scheme proposed. Then the analysis of protection scheme options for the fully rated converter, direct-driven PMSGs are examined and performed with simulation comparisons. Further, the protection schemes for wind farm collection and transmission systems are studied in terms of voltage level, collection level wind farm collection grids and high-voltage transmission systems for multi-terminal DC connected transmission systems, the so-called “Supergrid”. Throughout the thesis, theoretical analyses of fault transient performances are detailed with PSCAD/EMTDC simulation results for verification. Finally, the economic aspect for possible redundant design of wind farm electrical systems is investigated based on operational and economic statistics from an example wind farm project

    Offshore Electrical Networks and Grid Integration of Wave Energy Converter Arrays - Techno-economic Optimisation of Array Electrical Networks, Power Quality Assessment, and Irish Market Perspectives

    Get PDF
    Wave energy is an emerging industry and faces many challenges before commercial wave energy converter (WEC) arrays are installed. One of these challenges is the grid integration of WEC arrays. This includes offshore electrical networks, grid compliance, and access to electrical markets. This must be achieved in a technically viable manner and also at an acceptable cost. As electrical networks are expected to make up a large proportion of the overall WEC array CAPEX, perhaps up to 25%, this area is critical to the long term competitiveness of wave energy. The objectives of this thesis are to develop technically and economically acceptable electrical network designs for WEC arrays, evaluate voltage flicker issues for WEC arrays and develop design tools to analyse same, and evaluate the market scale for wave energy in Ireland, considering electrical integration issues in both the domestic and export markets. This thesis presents the optimum design for WEC array electrical networks. By building from the industry state of the art, including offshore wind experience, a comprehensive techno-economic optimisation process is undertaken. This includes optimising the key electrical interfaces between the WEC and the array electrical network, optimising the array network configuration, assessing efficiency of the network, and demonstrating that the network can be achieved at a cost which will allow competitiveness. Some challenges to the economics of WEC array electrical networks and some strategies for improving the economics are presented in this research also. The results provide timely guidance to WEC and WEC array developers. This research also demonstrates the critical link between voltage flicker emissions from WECs and the primary resource, i.e. ocean waves. Some practical assessment tools for the evaluation of this power quality issue are shown to assist in quantifying the problem. Also the full flicker performance of a candidate WEC is assessed helping characterise this link further. In this thesis both the domestic and export markets for Ireland’s wave energy resource are assessed as, although Ireland has an enviable wave energy resource, it is unclear where the market for this resource lies. This analysis shows that the medium term market for wave energy in Ireland is an export market. Also, although technically feasible, there is an additional cost for export transmission which must be considered in evaluating export markets. Some of the critical grid integration issues have been evaluated and addressed in this thesis. Future work is recommended in the areas of weather risk to cable installation at high energy wave sites, evaluating the benefits of shared electrical infrastructure across a range of renewable projects, designing offshore substations for WEC arrays, and quantifying the benefits of the addition of wave energy to the Irish renewable energy mix

    Modeling for harmonic analysis of ac offshore wind power plants

    Get PDF
    This Ph.D. dissertation presents the work carried out on the modeling, for harmonic analysis, of AC offshore wind power plants (OWPP). The studies presented in this Ph.D. thesis are oriented to two main aspects regarding the harmonic analysis of this type of power system. The first aspect is the modeling and validation of the main power components of an AC offshore wind power plant. Special emphasis is focused on the modeling of wind turbines, power transformers, submarine cables, and the interaction between them. A proposal of a wind turbine harmonic model is presented in this dissertation to represent the behavior of a wind turbine and its harmonics, up to 5 kHz. The distinctive structure of this model consists of implementing a voltage source containing both the fundamental component and the harmonics emitted by the converter. For the case of transformer and submarine cables, the frequency-dependent behavior of certain parameters is modeled for frequencies up to 5 kHz as well. The modeling of the frequency-dependent characteristics, due to skin and proximity effect, is achieved by means of Foster equivalent networks for time-domain simulations. Regarding the interaction between these power components, two complementary modeling approaches are presented. These are the SimulinkÂŽ-based model and an analytical sequence network model of the passive components of the OWPP. A description of model development and parameterization is carried out for both modeling approaches considering a scenario that is defined according to a real offshore wind power plant. On the other hand, the second aspect of this Ph.D. thesis is oriented to the analysis of the issues that appear in offshore wind power plants in relation to harmonic amplification risk, compliance of grid codes in terms of harmonics and power factor, and the design of effective solutions to improve the harmonic emission of the facility. The technical solutions presented in this Ph.D. thesis cover aspects regarding modulation strategies, design of the connection filter of the grid side converter and management of the operation point of the grid side converter of wind turbines. This last by means of changing the setpoint of certain variables. As inferred, these are solutions from the perspective of the wind turbine manufacturer

    Conclusions and Future Work

    Get PDF

    Economic Challenges and Optimisation of Ocean Energy Electrical Systems

    Get PDF
    • …