13 research outputs found

    Fast spiral-scan atomic force microscopy

    Get PDF
    In this paper, we describe a new scanning technique for fast atomic force microscopy. In this method, the sample is scanned in a spiral pattern instead of the well established raster pattern. A spiral scan can be produced by applying single frequency cosine and sine signals with slowly varying amplitudes to the x -axis and y -axis of an atomic force microscope (AFM) scanner respectively. The use of the single tone input signals allows the scanner to move at high speeds without exciting the mechanical resonance of the device and with relatively small control efforts. Experimental results obtained by implementing this technique on a commercial AFM indicate that high-quality images can be generated at scan frequencies well beyond the raster scans

    A new scanning method for fast atomic force microscopy

    Get PDF
    In recent years, the atomic force microscope (AFM) has become an important tool in nanotechnology research. It was first conceived to generate 3-D images of conducting as well as nonconducting surfaces with a high degree of accuracy. Presently, it is also being used in applications that involve manipulation of material surfaces at a nanoscale. In this paper, we describe a new scanning method for fast atomic force microscopy. In this technique, the sample is scanned in a spiral pattern instead of the well-established raster pattern. A constant angular velocity spiral scan can be produced by applying single frequency cosine and sine signals with slowly varying amplitudes to the x-axis and y -axis of AFM nanopositioner, respectively. The use of single-frequency input signals allows the scanner to move at high speeds without exciting the mechanical resonance of the device. Alternatively, the frequency of the sinusoidal set points can be varied to maintain a constant linear velocity (CLV) while a spiral trajectory is being traced. Thus, producing a CLV spiral. These scan methods can be incorporated into most modern AFMs with minimal effort since they can be implemented in software using the existing hardware. Experimental results obtained by implementing the method on a commercial AFM indicate that high-quality images can be generated at scan frequencies well beyond the raster scans

    Improvement in the Imaging Performance of Atomic Force Microscopy: A Survey

    Get PDF
    Nanotechnology is the branch of science which deals with the manipulation of matters at an extremely high resolution down to the atomic level. In recent years, atomic force microscopy (AFM) has proven to be extremely versatile as an investigative tool in this field. The imaging performance of AFMs is hindered by: 1) the complex behavior of piezo materials, such as vibrations due to the lightly damped low-frequency resonant modes, inherent hysteresis, and creep nonlinearities; 2) the cross-coupling effect caused by the piezoelectric tube scanner (PTS); 3) the limited bandwidth of the probe; 4) the limitations of the conventional raster scanning method using a triangular reference signal; 5) the limited bandwidth of the proportional-integral controllers used in AFMs; 6) the offset, noise, and limited sensitivity of position sensors and photodetectors; and 7) the limited sampling rate of the AFM's measurement unit. Due to these limitations, an AFM has a high spatial but low temporal resolution, i.e., its imaging is slow, e.g., an image frame of a living cell takes up to 120 s, which means that rapid biological processes that occur in seconds cannot be studied using commercially available AFMs. There is a need to perform fast scans using an AFM with nanoscale accuracy. This paper presents a survey of the literature, presents an overview of a few emerging innovative solutions in AFM imaging, and proposes future research directions.This work was supported in part by the Australian Research Council (ARC) under Grant FL11010002 and Grant DP160101121 and the UNSW Canberra under a Rector's Visiting Fellowshi

    High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

    Get PDF
    This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM's piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method

    Algorithm for a high precision contactless measurement system

    Full text link

    Nanopositionnement 3D à base de mesure à courant tunnel et piezo-actionnement

    Get PDF
    The objective of this thesis was to elaborate high performance control strategies and their real-time validation on a tunneling current-based 3D nanopositioning system developed in GIPSA-lab. The thesis lies in the domain of micro-/nano mechatronic systems (MEMS) focused on applications of fast and precise positioning and scanning tunneling microscopy (STM). More precisely, the aim is to position the metallic tunneling tip (like in STM) over the metallic surface using piezoelectric actuators in X, Y and Z directions and actuated micro-cantilever (like in Atomic Force Microscope AFM), electrostatically driven in Z direction, with high precision, over possibly high bandwidth. However, the presence of different adverse effects appearing at such small scale (e.g. measurement noise, nonlinearities of different nature, cross-couplings, vibrations) strongly affect the overall performance of the 3D system. Therefore a high performance control is needed. To that end, a novel 3D model of the system has been developed and appropriate control methods for such a system have been elaborated. First the focus is on horizontal X and Y directions. The nonlinear hysteresis and creep effects exhibited by piezoelectric actuators have been compensated and a comparison between different compensation methods is provided. Modern SISO and MIMO robust control methods are next used to reduce high frequency effects of piezo vibration and cross-couplings between X and Y axes. Next, the horizontal motion is combined with the vertical one (Z axis) with tunneling current and micro-cantilever control. Illustrative experimental results for 3D nanopositioning of tunneling tip, as well as simulation results for surface topography reconstruction and multi-mode cantilever positioning, are finally given.L'objectif de la thèse est l'élaboration de lois de commande de haute performance et leur validation en temps réel sur une plateforme expérimentale 3D de nano-positionnement à base de courant à effet tunnel, développée au laboratoire GIPSA-lab. Elle s'inscrit donc dans le cadre des systèmes micro-/nano-mécatronique (MEMS), et de la commande. Plus précisément, le principal enjeu considéré est de positionner la pointe métallique à effet tunnel (comme en microscopie à effet tunnel STM) contre la surface métallique en utilisant des actionneurs piézoélectriques en X, Y et Z et un micro-levier (comme en microscopie à force atomique AFM) actionné électrostatiquement en Z avec une grande précision et une bande passante élevée. Cependant, la présence de différents effets indésirables apparaissant à cette petite échelle (comme le bruit de mesure, des non-linéarités de natures différentes, les couplages, les vibrations) affectent fortement la performance globale du système 3D. En conséquence, une commande de haute performance est nécessaire. Pour cela, un nouveau modèle 3D du système a été développé et des méthodes de contrôle appropriées pour un tel système ont été élaborées. Tout d'abord l'accent est mis sur de positionnement selon les axes X et Y. Les effets d'hystérésis et de fluage non linéaires présents dans les actionneurs piézoélectriques ont été compensés et une comparaison entre les différentes méthodes de compensation est effectuée. Des techniques modernes de commande robuste SISO et MIMO sont ensuite utilisées pour réduire les effets des vibrations piézoélectriques et des couplages entre les axes X et Y. Le mouvement horizontal est alors combiné avec le mouvement vertical (Axe Z) et une commande du courant tunnel et du micro-levier. Des résultats expérimentaux illustrent le nano positionnement 3D de la pointe, et des résultats de simulation pour la reconstruction de la topographie de la surface ainsi que le positionnement du micro-levier à base d'un modèle multi-modes

    Silver nanocolloid generation using dynamic laser ablation synthesis in solution system and drop-casting

    Get PDF
    Conductive inks allow for low cost and scalable deposition of conductive tracks and patterns for printed electronics. Metal nanoparticle colloids are a novel form for producing conductive inks. Laser Ablation Synthesis in Solution (LASiS) is a “green” method for the production of metal nanoparticle colloids without the need for environmentally hazardous chemicals, however the method has typically been limited by its low production rates. This study reports on the generation of an additive free silver nanocolloid with maximized productivity using a flow-based LASiS system and its characterization using dynamic light scattering, UV–VIS, transmission electron microscopy and field emission scanning electron microscopy. The productivity of the LASiS silver nanoparticle (size 34 ± 5 nm) was 0.9 mg mL−1. While the flow-based system achieves high laser ablation rates in the mass of nanomaterial generated per unit time, the volume of liquid required for the flow leads to relatively low concentrations. Therefore, in this work, LASiS concentrated ink was formulated via a centrifugal method, which was then drop-cast and heat treated to produce a conductive silver layer. Centrifuging to concentrate the ink was shown to be a necessary step to achieve good results, with the lowest resistance across the drop-cast material of 60.2 after annealing

    Algorithm for a high precision contactless measurement system

    Get PDF
    This paper presents a Monte Carlo simulation of the self-calibration method for the multi laser tracker system (MLTS) which can track a retroreflector mounted on a kinematical system (e.g. positioning stage, robot manipulator etc.). Four laser trackers build up the MLTS. In the first part of the study the required algorithms enabling the MLTS to measure the position of the retroreflector are presented. The algorithms include the localization of the retroreflector, the communication between the laser trackers and the tracking controller as well as the calculation of the Tool Centre Point (TCP) position. In the second part of this study a deeper analysis of the self-calibration algorithm is carried out. A Monte Carlo simulation shows that the quality of the parameter estimation highly depends on the optimal arrangement of the MTLS

    New Trends in Energy Harvesting from Earth Long-Wave Infrared Emission

    Get PDF
    A review, even if not exhaustive, on the current technologies able to harvest energy from Earth's thermal infrared emission is reported. In particular, we discuss the role of the rectenna system on transforming the thermal energy, provided by the Sun and reemitted from the Earth, in electricity. The operating principles, efficiency limits, system design considerations, and possible technological implementations are illustrated. Peculiar features of THz and IR antennas, such as physical properties and antenna parameters, are provided. Moreover, some design guidelines for isolated antenna, rectifying diode, and antenna coupled to rectifying diode are exploited

    Acta Universitatis Sapientiae - Electrical and Mechanical Engineering

    Get PDF
    Series Electrical and Mechanical Engineering publishes original papers and surveys in various fields of Electrical and Mechanical Engineering
    corecore