1,562 research outputs found

    Implantation of 3D-Printed Patient-Specific Aneurysm Models into Cadaveric Specimens: A New Training Paradigm to Allow for Improvements in Cerebrovascular Surgery and Research.

    Get PDF
    AimTo evaluate the feasibility of implanting 3D-printed brain aneurysm model in human cadavers and to assess their utility in neurosurgical research, complex case management/planning, and operative training.MethodsTwo 3D-printed aneurysm models, basilar apex and middle cerebral artery, were generated and implanted in four cadaveric specimens. The aneurysms were implanted at the same anatomical region as the modeled patient. Pterional and orbitozygomatic approaches were done on each specimen. The aneurysm implant, manipulation capabilities, and surgical clipping were evaluated.ResultsThe 3D aneurysm models were successfully implanted to the cadaveric specimens' arterial circulation in all cases. The features of the neck in terms of flexibility and its relationship with other arterial branches allowed for the practice of surgical maneuvering characteristic to aneurysm clipping. Furthermore, the relationship of the aneurysm dome with the surrounding structures allowed for better understanding of the aneurysmal local mass effect. Noticeably, all of these observations were done in a realistic environment provided by our customized embalming model for neurosurgical simulation.Conclusion3D aneurysms models implanted in cadaveric specimens may represent an untapped training method for replicating clip technique; for practicing certain approaches to aneurysms specific to a particular patient; and for improving neurosurgical research

    Extended Endoscopic Endonasal Approaches for Cerebral Aneurysms: Anatomical, Virtual Reality and Morphometric Study

    Get PDF
    Introduction. The purpose of the present contribution is to perform a detailed anatomic and virtual reality three-dimensional stereoscopic study in order to test the effectiveness of the extended endoscopic endonasal approaches for selected anterior and posterior circulation aneurysms. Methods. The study was divided in two main steps: (1) simulation step, using a dedicated Virtual Reality System (Dextroscope, Volume Interactions); (2) dissection step, in which the feasibility to reach specific vascular territory via the nose was verified in the anatomical laboratory. Results. Good visualization and proximal and distal vascular control of the main midline anterior and posterior circulation territory were achieved during the simulation step as well as in the dissection step (anterior communicating complex, internal carotid, ophthalmic, superior hypophyseal, posterior cerebral and posterior communicating, basilar, superior cerebellar, anterior inferior cerebellar, vertebral, and posterior inferior cerebellar arteries). Conclusion. The present contribution is intended as strictly anatomic study in which we highlighted some specific anterior and posterior circulation aneurysms that can be reached via the nose. For clinical applications of these approaches, some relevant complications, mainly related to the endonasal route, such as proximal and distal vascular control, major arterial bleeding, postoperative cerebrospinal fluid leak, and olfactory disturbances must be considered

    Implantation of 3D-Printed Patient-Specific Aneurysm Models into Cadaveric Specimens: A New Training Paradigm to Allow for Improvements in Cerebrovascular Surgery and Research

    Get PDF
    Aim. To evaluate the feasibility of implanting 3D-printed brain aneurysm model in human cadavers and to assess their utility in neurosurgical research, complex case management/planning, and operative training. Methods. Two 3D-printed aneurysm models, basilar apex and middle cerebral artery, were generated and implanted in four cadaveric specimens. The aneurysms were implanted at the same anatomical region as the modeled patient. Pterional and orbitozygomatic approaches were done on each specimen. The aneurysm implant, manipulation capabilities, and surgical clipping were evaluated. Results. The 3D aneurysm models were successfully implanted to the cadaveric specimens’ arterial circulation in all cases. The features of the neck in terms of flexibility and its relationship with other arterial branches allowed for the practice of surgical maneuvering characteristic to aneurysm clipping. Furthermore, the relationship of the aneurysm dome with the surrounding structures allowed for better understanding of the aneurysmal local mass effect. Noticeably, all of these observations were done in a realistic environment provided by our customized embalming model for neurosurgical simulation. Conclusion. 3D aneurysms models implanted in cadaveric specimens may represent an untapped training method for replicating clip technique; for practicing certain approaches to aneurysms specific to a particular patient; and for improving neurosurgical research

    Trends in Cerebrovascular Surgery and Interventions

    Get PDF
    This is an open access proceeding book of 9th European-Japanese Cerebrovascular Congress at Milan 2018. Since many experts from Europe and Japan had very important and fruitful discussion on the management of Cerebrovascular diseases, the proceeding book is very attractive for the physician and scientists of the area

    A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models

    Get PDF
    Computational modeling is often used to quantify hemodynamic alterations induced by stenting, but frequently uses simplified device or vascular representations. Based on a series of Boolean operations, we developed an efficient and robust method for assessing the influence of current and next-generation stents on local hemodynamics and vascular biomechanics quantified by computational fluid dynamics. Stent designs were parameterized to allow easy control over design features including the number, width and circumferential or longitudinal spacing of struts, as well as the implantation diameter and overall length. The approach allowed stents to be automatically regenerated for rapid analysis of the contribution of design features to resulting hemodynamic alterations. The applicability of the method was demonstrated with patient-specific models of a stented coronary artery bifurcation and basilar trunk aneurysm constructed from medical imaging data. In the coronary bifurcation, we analyzed the hemodynamic difference between closed-cell and open-cell stent geometries. We investigated the impact of decreased strut size in stents with a constant porosity for increasing flow stasis within the stented basilar aneurysm model. These examples demonstrate the current method can be used to investigate differences in stent performance in complex vascular beds for a variety of stenting procedures and clinical scenarios

    Preventing Rupture: Clipping of Unruptured Intracranial Aneurysms

    Get PDF
    Unruptured intracranial aneurysms (UIAs) represent a major public health issue due to their unpredictable natural history. Whether to actively treat them or to maintain them under observation remains a hotly disputed topic. In this chapter, we present a review of the literature regarding the history of clipping and its use in UIAs, as well as the experience of our senior author in this field. We performed an extensive Medline and Google Academic search of the relevant literature. We have also made a retrospective analysis on patients harboring UIAs and multiple intracranial aneurysms (MIAs) clipped by the senior author between 1997 and 2017. About 89 patients had solitary UIAs, alongside 101 with MIAs possessing 257 individual aneurysms in total. All UIA patients were discharged with a favorable neurological outcome and no mortality. Concerning MIAs, the majority of cases had 2 aneurysms, the highest number being 6. And, 61 patients from this group had a favorable outcome. In the hands of experienced vascular neurosurgeons, clipping remains a safe option for both UIAs and MIAs. This procedure offers a long-lasting protection from aneurysmal rupture. In the future, new clip technologies and intraprocedural methods of verifying vessel patency and aneurysmal occlusion may further enhance postoperative results

    Endoscopic Management of Cavernous Carotid Surgical Complications: Evaluation of a Simulated Perfusion Model

    Get PDF
    Objective—Endoscopic surgical treatment of pituitary tumors, lateral invading tumors, or aneurysms requires surgeons to operate adjacent to the cavernous sinus. During these endoscopic endonasal procedures, the carotid artery is vulnerable to surgical injury at its genu. The objective of this simulation model was to evaluate trainees regarding management of a potentially lifethreatening vascular injury. Methods—Cadaveric heads were prepared in accordance with the Oregon Health & Science University body donation program. An endoscopic endonasal approach was used, and a perfusion pump with a catheter was placed in the ipsilateral common carotid artery at its origin in the neck. Learners used a muscle graft to establish vascular control and were evaluated over 3 training sessions. Simulation assessment, blood loss during sessions, and performance metric data were collected for learners. Results—Vascular control was obtained at a mean arterial pressure of 65 mm Hg using a muscle graft correctly positioned at the arteriotomy site. Learners improved over the course of training, with senior residents (n = 4) performing better across all simulation categories (situation awareness, decision making, communications and teamwork, and leadership); the largest mean difference was in communication and teamwork. Additionally, learner performance concerning blood loss improved between sessions (t = 3.667, P \u3c 0.01). Conclusions—In this pilot endoscopic endonasal simulation study, we successfully demonstrate a vascular complication perfusion model. Learners were able to gain direct applicable expertise in endoscopic endonasal techniques, instrumentation use, and teamwork required to optimize the technique. Learners gained skills of vascular complication management that transcend this model

    Computer simulations in stroke prevention : design tools and strategies towards virtual procedure planning

    Get PDF

    Ventriculoperitoneal shunt failure and infection: a retrospective review at Queen Mary Hospital

    Get PDF
    Oral Poster Paper IBACKGROUND: Ventriculoperitoneal shunting is a commonly performed procedure for diversion of cerebrospinal fluid. However shunt failure and infection results in significant morbidity and repeated operations. In this retrospective review study, ventriculoperitoneal shunting procedures performed at Queen Mary Hospital from January 2006 to December 2007 were reviewed. METHOD: All ventriculoperitoneal shunts performed within the period of January 2006 and December 2007 were included. Demographic data was obtained from medical record and department database. Shunt infection was defined as positive bacterial culture from cerebrospinal fluid. RESULTS: Totally 122 ventriculoperitoneal shunts were performed among 92 patients. Blockage was noted in 12 shunts. Shunt infection was documented in 12 cases, yielding an infection rate of 9.8%. No causal relationship was identified between shunt infection and systemic infection. Seven shunts were ligated or revised due to over-shunting. CONCLUSION: Many factors were postulated to be related to ventriculoperitoneal shunt infection or failure. However it is likely to be multifactorial. Upon performing a ventriculoperitoneal shunt, caution should be taken to prevent infection. Valve pressure should be carefully selected to prevent need of further revision due to over-shunting.postprin
    • …
    corecore