53,424 research outputs found

    Local DRLs and automated risk estimation in paediatric interventional cardiology

    Get PDF
    Introduction : Cardiac catheterization procedures result in high radiation doses and often multiple procedures are necessary for congenital heart disease patients. However, diagnostic reference levels (DRL) remain scarce. Our first goal was finding the optimal DRL parameter and determining appropriate DRLs. The second goal was to calculate organ doses (OD), effective doses (ED) and lifetime attributable risks (LAR) per procedure and to provide conversion factors based on dose area product (DAP). Materials and methods : DRLs are calculated for each procedure type, as the 75th percentile of the cumulative value per procedure from the corresponding parameter. All irradiation events in the DICOM Structured Reports were automatically processed and simulated using PCXMC, resulting in OD, ED and LAR. Using a Kruskal Wallis H test and subsequent pairwise comparisons, differences in median values of the DRL parameter between procedure types were assessed. Results : Linear regression showed a strong correlation and narrow confidence interval between DAP and product of body weight and fluoroscopy time (BWxFT), even when all procedures (diagnostic and interventional) are combined. Only 15% of the pairwise comparisons were statistically significant for DAP normalized to BWxFT (DAP(BWxFT)). The latter pairs contained less frequent procedure types with significant outliers. For DAP normalized to BW (DAP(BW)), 38% of the pairwise comparisons showed statistically significant differences. Conversion factors from DAP(BW) to OD and ED were reported for various weight groups, due to the higher correlation between DAP(BW) and both OD and ED than between DAP and both OD and ED. Conclusions : The P75 of DAP(BWxFT) for all procedures combined serves as an appropriate DRL value. This facilitates local DRL determination in smaller paediatric centres, which often have insufficient data to produce appropriate DRLs for different procedure types. Conversion factors are more reliable starting from DAP(BW) instead of DAP and should be used according to the appropriate BW group

    Oral diabetes medication monotherapy and short-term mortality in individuals with type 2 diabetes and coronary artery disease

    Get PDF
    Objective To determine whether sulfonylurea use, compared with non-sulfonylurea oral diabetes medication use, was associated with 2-year mortality in individuals with well-controlled diabetes and coronary artery disease (CAD). Research design and methods We studied 5352 US veterans with type 2 diabetes, obstructive CAD on coronary angiography, hemoglobin A1c ≤7.5% at the time of catheterization, and taking zero or one oral diabetes medication (categorized as no medications, non-sulfonylurea medication, or sulfonylurea). We estimated the association between medication category and 2-year mortality using inverse probability of treatment-weighted (IPW) standardized mortality differences and IPW multivariable Cox proportional hazards regression. Results 49%, 35%, and 16% of the participants were on no diabetes medications, non-sulfonylurea medications, and sulfonylureas, respectively. In individuals on no medications, non-sulfonylurea medications, and sulfonylureas, the unadjusted mortality rates were 6.6%, 5.2%, and 11.9%, respectively, and the IPW-standardized mortality rates were 5.9%, 6.5%, and 9.7%, respectively. The standardized absolute 2-year mortality difference between non-sulfonylurea and sulfonylurea groups was 3.2% (95% CI 0.7 to 5.7) (p=0.01). In Cox proportional hazards models, the point estimate suggested that sulfonylurea use might be associated with greater hazard of mortality than non-sulfonylurea medication use, but this finding was not statistically significant (HR 1.38 (95% CI 1.00 to 1.93), p=0.05). We did not observe significant mortality differences between individuals on no diabetes medications and non-sulfonylurea users. Conclusions Sulfonylurea use was common (nearly one-third of those taking medications) and was associated with increased 2-year mortality in individuals with obstructive CAD. The significance of the association between sulfonylurea use and mortality was attenuated in fully adjusted survival models. Caution with sulfonylurea use may be warranted for patients with well-controlled diabetes and CAD, and metformin or newer diabetes medications with cardiovascular safety data could be considered as alternatives when individualizing therapy

    International variation in invasive care of the elderly with acute coronary syndromes

    Get PDF
    Aims To explore variations in invasive care of the elderly with acute coronary syndromes across international practice. Methods and results Using combined populations from the SYMPHONY and 2nd SYMPHONY trials, we describe 30-day cardiac catheterization in elderly (≥75 years; n=1794) vs. younger patients (<75 years; n=14 043) after multivariable adjustment and by region of enrolment. The use of cardiac catheterization and revascularization were not protocol-specified. Elderly patients (median age 78 years) were more often female and more frequently had hypertension, diabetes, prior myocardial infarction, and prior coronary bypass surgery. Overall, they underwent less cardiac catheterization than younger patients [53 vs. 63%; adjusted OR 0.53 (0.46, 0.60)]. The absolute rate of cardiac catheterization in the elderly varied from 77% (vs. 91% in younger patients) in the US cohort to 27% (vs. 41% in younger patients) in the non-US cohort. Revascularization of elderly who underwent cardiac catheterization was also higher in US than non-US cohorts (71.3 vs. 53.6%). There was a significant interaction between the patient age and the use of catheterization across US and non-US regions of enrolment, as well as differences in the predictors of catheterization in the elderly. Despite these findings, after adjustment, 90-day rates of death and death or myocardial infarction (MI) were not significantly different in elderly who underwent catheterization compared with those who did not. Conclusion Although older age is universally predictive of lower use of cardiac catheterization, marked variation in catheterization of the elderly exists across international practice. Demonstrated differences in patterns of use suggest a lack of consensus regarding optimal use of an invasive strategy in the elderl

    Coronary artery grafting in infants

    Get PDF
    Coronary artery bypass grafting (CABG) with cardiac vale repair is an uncommon surgery in infants. CABG is technically demanding in infants due to the small size not only of the coronary arteries but also the potential graft arteries. The short and long-term outcome of surgery is not known and thus has largely been avoided. This article reports the case histories of two infants in whom CABG was undertaken successfully as a life-saving measure.peer-reviewe

    Barnes Hospital Bulletin

    Get PDF
    https://digitalcommons.wustl.edu/bjc_barnes_bulletin/1157/thumbnail.jp

    Novel X-ray imaging technology enables significant patient dose reduction in interventional cardiology while maintaining diagnostic image quality

    Get PDF
    Objectives: The purpose of this study was to quantify the reduction in patient radiation dose during coronary angiography (CA) by a new X-ray technology, and to assess its impact on diagnostic image quality. Background: Recently, a novel X-ray imaging technology has become available for interventional cardiology, using advanced image processing and an optimized acquisition chain for radiation dose reduction. Methods: 70 adult patients were randomly assigned to a reference X-ray system or the novel X-ray system. Patient demographics were registered and exposure parameters were recorded for each radiation event. Clinical image quality was assessed for both patient groups. Results: With the same angiographic technique and a comparable patient population, the new imaging technology was associated with a 75% reduction in total kerma-area product (KAP) value (decrease from 47 Gycm(2) to 12 Gycm(2), P<0.001). Clinical image quality showed an equivalent detail and contrast for both imaging systems. On the other hand, the subjective appreciation of noise was more apparent in images of the new image processing system, acquired at lower doses, compared to the reference system. However, the higher noise content did not affect the overall image quality score, which was adequate for diagnosis in both systems. Conclusions: For the first time, we present a new X-ray imaging technology, combining advanced noise reduction algorithms and an optimized acquisition chain, which reduces patient radiation dose in CA drastically (75%), while maintaining diagnostic image quality. Use of this technology may further improve the radiation safety of cardiac angiography and interventions

    Focal Spot, Fall 1984

    Get PDF
    https://digitalcommons.wustl.edu/focal_spot_archives/1038/thumbnail.jp
    corecore