16,965 research outputs found
Multilayered broadband antenna for compact embedded implantable medical devices: design and characterization
Design and characterization of a multilayered compact implantable broadband antenna for wireless biotelemetry applications is presented in this paper. The main features of this novel design are miniaturized size, structure that allows integration of electronic circuits of the implantable medical device inside the antenna, and enhanced bandwidth that mitigates possible frequency detuning caused by heterogeneity of biological tissues. Using electromagnetic simulations based on the finite-difference timedomain method, the antenna geometry was optimized to operate in the 401-406 MHz Medical Device Radio communications service band. The proposed design was simulated implanted in a muscle tissue cuboid phantom and implanted in the arm, head, and chest of a high-resolution whole-body anatomical numerical model of an adult human male. The antenna was fabricated using low-temperature co-fired ceramic technology. Measurements validated simulation results for the antenna implanted in muscle tissue cuboid phantom. The proposed compact antenna, with dimensions of 14 mm Ă 16 mm Ă 2 mm, presented a â10 dB bandwidth of 103 MHz and 92 MHz for simulations and measurements, respectively. The proposed antenna allows integration of electronic circuit up to 10 mm Ă 10 mm Ă 0.5 mm. Specific absorption rate distributions, antenna input power, radiation pattern and the transmission channel between the proposed antenna and a half-wavelength dipole were evaluated
A comprehensive survey of wireless body area networks on PHY, MAC, and network layers solutions
Recent advances in microelectronics and integrated circuits, system-on-chip design, wireless communication and intelligent low-power sensors have allowed the realization of a Wireless Body Area Network (WBAN). A WBAN is a collection of low-power, miniaturized, invasive/non-invasive lightweight wireless sensor nodes that monitor the human body functions and the surrounding environment. In addition, it supports a number of innovative and interesting applications such as ubiquitous healthcare, entertainment, interactive gaming, and military applications. In this paper, the fundamental mechanisms of WBAN including architecture and topology, wireless implant communication, low-power Medium Access Control (MAC) and routing protocols are reviewed. A comprehensive study of the proposed technologies for WBAN at Physical (PHY), MAC, and Network layers is presented and many useful solutions are discussed for each layer. Finally, numerous WBAN applications are highlighted
Wireless body sensor networks for health-monitoring applications
This is an author-created, un-copyedited version of an article accepted for publication in
Physiological Measurement. The publisher is
not responsible for any errors or omissions in this version of the manuscript or any version
derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0967-3334/29/11/R01
On-body wearable repeater as a data link relay for in-body wireless implants
Wireless medical devices implanted at different locations in the human body have a wide application range. Yet, high-data-rate communication in the 2.4-GHz Industrial, Scientific, and Medical band suffers from high in-body attenuation loss. Link improvement cannot be obtained by simply increasing transmit power, as battery life is limited and in-body absorption has to remain low. To overcome these problems, a flexible on-body textile patch antenna, robustly matched directly to the human body, is designed and developed as part of a wearable repeater, enhancing communication with implanted wireless devices. This receive antenna, which can cope with different morphologies and patient movements, enables reliable high data rate and low-power communication links with an implant. A data link measurement is performed for the on-body repeater system placed on the human torso, relaying the signals to nearby medical equipment, without wired connection to the patient. The performance of the data link is experimentally assessed in different measurement scenarios. For a repeater system relying on simple analog amplification, which is low-cost, energy-efficient, and can be fully integrated into clothing, excellent results are obtained, with an average measured signal-to-noise ratio of 33 dB for tissue depths up to 85 mm
Non-Invasive Induction Link Model for Implantable Biomedical Microsystems: Pacemaker to Monitor Arrhythmic Patients in Body Area Networks
In this paper, a non-invasive inductive link model for an Implantable
Biomedical Microsystems (IBMs) such as, a pacemaker to monitor Arrhythmic
Patients (APs) in Body Area Networks (BANs) is proposed. The model acts as a
driving source to keep the batteries charged, inside a device called,
pacemaker. The device monitors any drift from natural human heart beats, a
condition of arrythmia and also in turn, produces electrical pulses that create
forced rhythms that, matches with the original normal heart rhythms. It
constantly sends a medical report to the health center to keep the medical
personnel aware of the patient's conditions and let them handle any critical
condition, before it actually happens. Two equivalent models are compared by
carrying the simulations, based on the parameters of voltage gain and link
efficiency. Results depict that the series tuned primary and parallel tuned
secondary circuit achieves the best results for both the parameters, keeping in
view the constraint of coupling co-efficient (k), which should be less than a
value \emph{0.45} as, desirable for the safety of body tissues.Comment: IEEE 8th International Conference on Broadband and Wireless
Computing, Communication and Applications (BWCCA'13), Compiegne, Franc
Neuro-electronic technology in medicine and beyond
This dissertation looks at the technology and social issues involved with interfacing electronics directly to the human nervous system, in particular the methods for both reading and stimulating nerves. The development and use of cochlea implants is discussed, and is compared with recent developments in artificial vision. The final sections consider a future for non-medicinal applications of neuro-electronic technology. Social attitudes towards use for both medicinal and non-medicinal purposes are discussed, and the viability of use in the latter case assessed
Recommended from our members
Wireless optogenetics protects against obesity via stimulation of non-canonical fat thermogenesis.
Cold stimuli and the subsequent activation of ÎČ-adrenergic receptor (ÎČ-AR) potently stimulate adipose tissue thermogenesis and increase whole-body energy expenditure. However, systemic activation of the ÎČ3-AR pathway inevitably increases blood pressure, a significant risk factor for cardiovascular disease, and, thus, limits its application for the treatment of obesity. To activate fat thermogenesis under tight spatiotemporal control without external stimuli, here, we report an implantable wireless optogenetic device that bypasses the ÎČ-AR pathway and triggers Ca2+ cycling selectively in adipocytes. The wireless optogenetics stimulation in the subcutaneous adipose tissue potently activates Ca2+ cycling fat thermogenesis and increases whole-body energy expenditure without cold stimuli. Significantly, the light-induced fat thermogenesis was sufficient to protect mice from diet-induced body-weight gain. The present study provides the first proof-of-concept that fat-specific cold mimetics via activating non-canonical thermogenesis protect against obesity
A Review of Wireless Body Area Networks for Medical Applications
Recent advances in Micro-Electro-Mechanical Systems (MEMS) technology,
integrated circuits, and wireless communication have allowed the realization of
Wireless Body Area Networks (WBANs). WBANs promise unobtrusive ambulatory
health monitoring for a long period of time and provide real-time updates of
the patient's status to the physician. They are widely used for ubiquitous
healthcare, entertainment, and military applications. This paper reviews the
key aspects of WBANs for numerous applications. We present a WBAN
infrastructure that provides solutions to on-demand, emergency, and normal
traffic. We further discuss in-body antenna design and low-power MAC protocol
for WBAN. In addition, we briefly outline some of the WBAN applications with
examples. Our discussion realizes a need for new power-efficient solutions
towards in-body and on-body sensor networks.Comment: 7 pages, 7 figures, and 3 tables. In V3, the manuscript is converted
to LaTe
- âŠ