94,299 research outputs found

    Rheology of human blood plasma: Viscoelastic versus Newtonian behavior

    Full text link
    We investigate the rheological characteristics of human blood plasma in shear and elongational flows. While we can confirm a Newtonian behavior in shear flow within experimental resolution, we find a viscoelastic behavior of blood plasma in the pure extensional flow of a capillary break-up rheometer. The influence of the viscoelasticity of blood plasma on capillary blood flow is tested in a microfluidic device with a contraction-expansion geometry. Differential pressure measurements revealed that the plasma has a pronounced flow resistance compared to that of pure water. Supplementary measurements indicate that the viscoelasticity of the plasma might even lead to viscoelastic instabilities under certain conditions. Our findings show that the viscoelastic properties of plasma should not be ignored in future studies on blood flow.Comment: 4 figures, 1 supplementary material Highlighted in http://physics.aps.org/articles/v6/1

    Direct replacement of antibodies with molecularly imprinted polymer (MIP) nanoparticles in ELISA - development of a novel assay for vancomycin

    Get PDF
    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop ELISA type assays is presented here for the first time. NanoMIPs were synthesized by a solid phase approach with immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering and electron microscopy. Immobilization, blocking and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a HRP-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was three orders of magnitude better than a previously described ELISA based on antibodies. In these experiments nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELIS

    Micro-scale blood plasma separation: from acoustophoresis to egg-beaters

    Get PDF
    Plasma is a rich mine of various biomarkers including proteins, metabolites and circulating nucleic acids. The diagnostic and therapeutic potential of these analytes has been quite recently uncovered, and the number of plasma biomarkers will still be growing in the coming years. A significant part of the blood plasma preparation is still handled manually, off-chip, via centrifugation or filtration. These batch methods have variable waiting times, and are often performed under non-reproducible conditions that may impair the collection of analytes of interest, with variable degradation. The development of miniaturised modules capable of automated and reproducible blood plasma separation would aid in the translation of lab-on-a-chip devices to the clinical market. Here we propose a systematic review of major plasma analytes and target applications, alongside existing solutions for micro-scale blood plasma extraction, focusing on the approaches that have been biologically validated for specific applications

    The ISFET based heparin sensor with a monolayer of protamine as affinity ligand

    Get PDF
    The ion-step measuring method was used to determine absolute heparin concentrations in PBS and blood plasma with a Ta2O5 ISFET on to which a monolayer of protamine had been immobilized. Heparin is a highly negatively charged polysaccharide, which is used clinically to delay the clotting of blood. Protamine acts as an affinity ligand for heparin. The response of the ISFET system on a step-wise increase in the electrolyte concentration (a so-called ion-step) is a transient change of the output voltage, which is related to the surface charge density of the ISFET gate oxide. After 2 mins of incubation in a plasma sample containing heparin, the amplitude of the transient ISFET response to an ion-step showed a linear relation to the heparin concentration. In blood plasma, heparin concentrations between 0·3 and 2·0 Units/ml could be determined with an accuracy of ±0·08 Units/ml. Heparin concentrations in different plasma samples of heparinized patients were determined and compared with the APTT. No direct relation was found between the APTT and the heparin concentration, but this result was not surprising

    Genetic variation in plasma transferrins of tambaqui, Colossoma macropomum (CUVIER 1818)

    No full text
    Blood specimens of tambaqui, Colossoma macropomum, an Amazonian fish of commercial importance, were examined for transferrin variants by treating blood plasma specimens with rivanol before electrophoretic analyses in starch gel media. A total of 6 co-dominant alleles at the transferrin locus in tambaqui was postulated to account for the 6 varieties of molecular components in 10 observed phenotypes. The population sample showed good genetic balance, characteristic of a unit stock

    Quantifying physiological influences on otolith microchemistry

    Get PDF
    Trace element concentrations in fish earstones (‘otoliths’) are widely used to discriminate spatially discrete populations or individuals of marine fish, based on a commonly held assumption that physiological influences on otolith composition are minor, and thus variations in otolith elemental chemistry primarily reflect changes in ambient water chemistry. We carried out a long-term (1-year) experiment, serially sampling seawater, blood plasma and otoliths of mature and immature European plaice (Pleuronectes platessa L.) to test relationships between otolith chemistry and environmental and physiological variables. Seasonal variations in otolith elemental composition did not track seawater concentrations, but instead reflected physiological controls on metal transport and biokinetics, which are likely moderated by ambient temperature. The influence of physiological factors on otolith composition was particularly evident in Sr/Ca ratios, the most widely used elemental marker in applied otolith microchemistry studies. Reproduction also triggered specific variations in otolith and blood plasma metal chemistry, especially Zn/Ca ratios in female fish, which could potentially serve as retrospective spawning indicators. The influence of physiology on the trace metal composition of otoliths may explain the success of microchemical stock discrimination in relatively homogenous marine environments, but could complicate alternative uses for trace element compositions in biominerals of higher organism

    The degree of mutual anisotropy of biological liquids polycrystalline nets as a parameter in diagnostics and differentiations of hominal inflammatory processes

    Get PDF
    To characterize the degree of consistency of parameters of the optically uniaxial birefringent protein nets of blood plasma a new parameter – complex degree of mutual anisotropy is suggested. The technique of polarization measuring the coordinate distributions of the complex degree of mutual anisotropy of blood plasma is developed. It is shown that statistic approach to the analysis of the complex degree of mutual anisotropy distributions of blood plasma is effective during the diagnostics and differentiation of an acute inflammatory processes as well as acute and gangrenous appendicitis

    Wavelet analysis for polarization inhomogeneous laser images of blood plasma

    Get PDF
    The possibilities of the local wavelet-analysis of polarization-inhomogeneous laser image of human blood plasma were considered. The set of statistics, correlation and fractal parameters of the distributions of wavelet-coefficients that are characterize different scales of the polarization maps of polycrystalline networks of amino acids of blood plasma were defined. The criteria for the differentiation of the transformation of birefringence optical-anisotropic structures of blood plasma at different scales of their geometric dimensions were determined

    Metabolic Signatures of Lung Cancer in Biofluids: NMR-Based Metabonomics of Blood Plasma

    Get PDF
    In this work, the variations in the metabolic profile of blood plasma from lung cancer patients and healthy controls were investigated through NMR-based metabonomics, to assess the potential of this approach for lung cancer screening and diagnosis. PLS-DA modeling of CPMG spectra from plasma, subjected to Monte Carlo Cross Validation, allowed cancer patients to be discriminated from controls with sensitivity and specificity levels of about 90%. Relatively lower HDL and higher VLDL + LDL in the patients' plasma, together with increased lactate and pyruvate and decreased levels of glucose, citrate, formate, acetate, several amino acids (alanine, glutamine, histidine, tyrosine, valine), and methanol, could be detected. These changes were found to be present at initial disease stages and could be related to known cancer biochemical hallmarks, such as enhanced glycolysis, glutaminolysis, and gluconeogenesis, together with suppressed Krebs cycle and reduced lipid catabolism, thus supporting the hypothesis of a systemic metabolic signature for lung cancer. Despite the possible confounding influence of age, smoking habits, and other uncontrolled factors, these results indicate that NMR-based metabonomics of blood plasma can be useful as a screening tool to identify suspicious cases for subsequent, more specific radiological tests, thus contributing to improved disease management.ERDF - Competitive Factors Thematic Operational ProgrammeFCT/PTDC/ QUI/68017/2006FCOMP-01-0124-FEDER-007439SFRH/BD/ 63430/2009National UNESCO Committee - L'Oréal Medals of Honor for Women in Science 200Portuguese National NMR Network - RNRM
    corecore