685,133 research outputs found

    Validation of an automated enzyme immunoassay for interleukin-6 for routine clinical use

    Get PDF
    Serum levels of Interleukin-6 (IL-6), a proinflammatory cytokine, are increased in early stages of inflammatory diseases such as infection and sepsis. Assay systems which permit its measurement within a few hours and as a single measurement have not been reported so far. We therefore evaluated a now commercially available automated method for IL-6 measurement on the Cobas Core(R) immunological analyzer (Roche Diagnostic Systems) which enables single IL-6 measurement within about 1 hour. The automated assay correlates well with an established, manual microtiter plate assay (Biosource GmbH) which uses the same antibodies and reagents (r=0.98). Accuracy of the automated method was established by adding known amounts of IL-6 international reference preparation. Recovery of the international standard was in the range of 92-104%. The automated assay had a precision of singletons below 6% and was linear up to 2800 pg/ml. This automated assay provides a suitable, convenient and time saving method for measurement of IL-6 serum levels in the routine clinical laboratory

    How accurate is your sclerostin measurement?:Comparison between three commercially available sclerostin ELISA kits

    Get PDF
    Sclerostin, bone formation antagonist is in the spotlight as a potential biomarker for diseases presenting with associated bone disorders such as chronic kidney disease (CDK-MBD). Accurate measurement of sclerostin is therefore important. Several immunoassays are available to measure sclerostin in serum and plasma. We compared the performance of three commercial ELISA kits. We measured sclerostin concentrations in serum and EDTA plasma obtained from healthy young (18-26 years) human subjects using kits from Biomedica, TECOmedical and from R&D Systems. The circulating sclerostin concentrations were systematically higher when measured with the Biomedica assay (serum: 35.5 ± 1.1 pmol/L; EDTA: 39.4 ± 2.0 pmol/L; mean ± SD) as compared with TECOmedical (serum: 21.8 ± 0.7 pmol/L; EDTA: 27.2 ± 1.3 pmol/L) and R&D Systems (serum: 7.6 ± 0.3 pmol/L; EDTA: 30.9 ± 1.5 pmol/L). We found a good correlation between the assay for EDTA plasma (r > 0.6; p < 0.001) while in serum, only measurements obtained using TECOmedical and R&D Systems assays correlated significantly (r = 0.78; p < 0.001). There was no correlation between matrices results when using the Biomedica kit (r = 0.20). The variability in values generated from Biomedica, R&D Systems and TECOmedical assays raises questions regarding the accuracy and specificity of the assays. Direct comparison of studies using different kits is not possible and great care should be given to measurement of sclerostin, with traceability of reagents. Standardization with appropriate material is required before different sclerostin assays can be introduced in clinical practice

    Phosphoenolpyruvate Carboxykinase Assayed at Physiological Concentrations of Metal Ions Has a High Affinity for CO2

    Get PDF
    The effect of Mn2+/Mg2+ concentration on the activity of intact, homogeneous phosphoenolpyruvate carboxykinase (PEPCK) from leaves of the C4 grass, Guinea grass (Panicum maximum), have been investigated. Assay conditions were optimized so that PEPCK activity could be measured at concentrations of Mn2+/Mg2+ similar to those found in the cytosol (low micromolar Mn2+ and millimolar Mg2+). PEPCK activity was totally dependent on Mn2+ and was activated at low micromolar concentrations of Mn2+ by millimolar concentrations of Mg2+. Therefore, at physiological concentrations of Mn2+, PEPCK has a requirement for Mg2+. Assay at physiological concentrations of Mn2+/Mg2+ led to a marked decrease in its affinity for ATP and a 13-fold increase in its affinity for CO2. The Km (CO2) was further decreased by assay at physiological ATP to ADP ratios, reaching values as low as 20 μM CO2, comparable with the Km (CO2) of ribulose 1,5-bisphosphate carboxylase-oxygenase. This means that PEPCK will catalyze a reversible reaction and that it could operate as a carboxylase in vivo, a feature that could be particularly important in algal CO2-concentrating systems

    Evaluation of the genotoxic and teratogenic potential of a municipal sludge and sludge-amended soil using the amphibian Xenopus laevis and the tobacco: Nicotiana tabacum L. var. xanthi Dulieu

    Get PDF
    The toxic, genotoxic and teratogenicpotential of amunicipal sewage sludge was assessed using the micronucleus assay on the larvae of the amphibianXenopuslaevis and with the tobacco somatic mutation test using the yellow–green xanthiDulieu mutant a1+/a1 a2+/a2. The teratogenicpotential was assessed by means of the Frog Embryo Teratogenesis Assay-Xenopus (FETAX). Various doses of the pasty sludge added to a crop soil were tested using the three bioassays. The test systems were performed either directly with sludge or sludge-amendedsoil samples (plant model) or with aqueous extracts (aquatic animal model). Using the tobacco model, we found no mutagenic impact of the soilamended with the sludge, perhaps because the clay-like nature of the soil, with its high adsorption capacity, may have prevented the contaminants from reaching the target. All leachates of amendedsoils produced a significant size reduction in Xenopus embryos. Depending on the soil/sludge ratio, some leachates were found to be genotoxic but were never teratogenic. This battery of in vivo test systems enabled us to estimate the global long-term effects under agricultural conditions with various genetic endpoints on ecologically relevant organisms characteristic of the aquatic and terrestrial compartments

    Metabolic response of environmentally isolated microorganisms to industrial effluents: Use of a newly described cell culture assay

    Get PDF
    An environmental application using a microtiter culture assay to measure the metabolic sensitivity of microorganisms to petrochemical effluents will be tested. The Biomedical Operations and Research Branch at NASA JSC has recently developed a rapid and nondestructive method to measure cell growth and metabolism. Using a colorimetric procedure the uniquely modified assay allows the metabolic kinetics of prokaryotic and eukaryotic cells to be measured. Use of such an assay if adapted for the routine monitoring of waste products, process effluents, and environmentally hazardous substances may prove to be invaluable to the industrial community. The microtiter method as described will be tested using microorganisms isolated from the Galveston Bay aquatic habitat. The microbial isolates will be identified prior to testing using the automated systems available at JSC. Sodium dodecyl sulfate (SDS), cadmium, and lead will provide control toxic chemicals. The toxicity of industrial effluent from two industrial sites will be tested. An effort will be made to test the efficacy of this assay for measuring toxicity in a mixed culture community

    The Bunsen gas solubility coefficient of ethylene as a function of temperature and salinity and its importance for nitrogen fixation assays

    Get PDF
    The acetylene reduction assay is a common method for assessing nitrogen fixation in a variety of marine and freshwater systems. The method measures ethylene, the product of the conversion of the gas acetylene to its reduced form by nitrogenase. Knowledge of the solubility of ethylene in aqueous solution is crucial to the calculation of nitrogen fixation rates and depends on the temperature and salinity of the assay conditions. Despite the increasing interest in marine nitrogen fixation, no gas solubility (Bunsen) coefficients for ethylene in seawater are published to date. Here, we provide a set of equations and present semiempirically derived Bunsen coefficients for ethylene in water (ranging from 0.069 to 0.226) for a range of temperatures and salinities that are relevant for aquatic nitrogen fixation. We apply these data to nitrogen fixation scenarios at different temperatures and salinities and stress the importance of using accurate Bunsen coefficients in nitrogen fixation assays

    A Magnetic Bead-Based Sensor for the Quantification of Multiple Prostate Cancer Biomarkers.

    Get PDF
    Novel biomarker assays and upgraded analytical tools are urgently needed to accurately discriminate benign prostatic hypertrophy (BPH) from prostate cancer (CaP). To address this unmet clinical need, we report a piezeoelectric/magnetic bead-based assay to quantitate prostate specific antigen (PSA; free and total), prostatic acid phosphatase, carbonic anhydrase 1 (CA1), osteonectin, IL-6 soluble receptor (IL-6sr), and spondin-2. We used the sensor to measure these seven proteins in serum samples from 120 benign prostate hypertrophy patients and 100 Gleason score 6 and 7 CaP using serum samples previously collected and banked. The results were analyzed with receiver operator characteristic curve analysis. There were significant differences between BPH and CaP patients in the PSA, CA1, and spondin-2 assays. The highest AUC discrimination was achieved with a spondin-2 OR free/total PSA operation--the area under the curve was 0.84 with a p value below 10(-6). Some of these data seem to contradict previous reports and highlight the importance of sample selection and proper assay building in the development of biomarker measurement schemes. This bead-based system offers important advantages in assay building including low cost, high throughput, and rapid identification of an optimal matched antibody pair
    corecore