10,988 research outputs found
A chemical ionization mass spectrometer for continuous underway shipboard analysis of dimethylsulfide in near-surface seawater
A compact, low-cost atmospheric pressure, chemical ionization mass spectrometer ("mini-CIMS") has been developed for continuous underway shipboard measurements of dimethylsulfide (DMS) in seawater. The instrument was used to analyze DMS in air equilibrated with flowing seawater across a porous Teflon membrane equilibrator. The equilibrated gas stream was diluted with air containing an isotopically-labeled internal standard. DMS is ionized at atmospheric pressure via proton transfer from water vapor, then declustered, mass filtered via quadrupole mass spectrometry, and detected with an electron multiplier. The instrument described here is based on a low-cost residual gas analyzer (Stanford Research Systems), which has been modified for use as a chemical ionization mass spectrometer. The mini-CIMS has a gas phase detection limit of 220 ppt DMS for a 1 min averaging time, which is roughly equivalent to a seawater DMS concentration of 0.1 nM DMS at 20°C. The mini-CIMS has the sensitivity, selectivity, and time response required for underway measurements of surface ocean DMS over the full range of oceanographic conditions. The simple, robust design and relatively low cost of the instrument are intended to facilitate use in process studies and surveys, with potential for long-term deployment on research vessels, ships of opportunity, and large buoys
Fast liquid chromatography/electrochemistry/mass spectrometry of ferrocenecarboxylic acid esters
Rapid liquid chromatographic separations of ferrocenecarboxylic esters of various alcohols and phenols have been achieved on reversed-phase columns of 20 mm length. After separation, the ferrocene derivatives are oxidized electrochemically under formation of the charged ferrocinium species, which are easily detected by mass spectrometry using an atmospheric pressure chemical ionization source operated in the heated nebulizer mode. While a series of nine phenol derivatives was separated within less than 1.5 min, six alcohol derivatives eluted within 1 min. Limits of detection using a single quadrupole mass analyzer ranged from 60 to 190 nmol/l. Additional work was directed on the use of a graphite in-line filter instead of a silica-based reversed-phase column to achieve the separation
A liquid chromatography tandem mass spectrometry method for simultaneous analysis of 46 atmospheric particulate-phase persistent organic pollutants and comparison with gas chromatography/mass spectrometry,
A novel multi-analyte method for the simultaneous determination of 46 compounds of environmental concern, most of them belonging to the category of persistent organic pollutants, was developed using high-performance liquid chromatography and the results were compared to those obtained by gas chromatography. This study was performed in perspective of a cumulative exposure assessment of substances of health concern in environments where high levels, relatively to airborne particulate matter, can be found. The target compounds included polychlorinated biphenyls, brominated flame-retardants and derivatives of polycyclic aromatic hydrocarbons.
The multi-analyte method was evaluated in air particulate matter in terms of reproducibility, linearity, recovery, limits of detection and quantification and matrix effect. The recovery was above 70% for all the analytes, whereas limits of quantification ranged between 23 and 390 pg.m(-3) in liquid chromatography and less than ten times in gas chromatography-mass spectrometry.
Matrix effect was generally negligible for both the techniques, except the case of the detection of oxygenated derivatives of polycyclic aromatic hydrocarbons by gas chromatography
Recommended from our members
Quantification of Dehydroepiandrosterone, 17β-Estradiol, Testosterone, and Their Sulfates in Mouse Tissues by LC-MS/MS.
We report a high-performance, liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay to quantify without derivatizaton dehyroepiandrosterone (DHEA), 17β-estradiol (E2), testosterone (T), and their sulfates in serum and tissues. This assay functions well with multiple adipose depots, a previously unattained analysis. To delipidate and facilitate recovery, tissues were homogenized in acetonitrile, and the homogenate was frozen. The supernatant was evaporated, resuspended in an aqueous acetate buffer, and extracted with hexane to separate free (unconjugated) from sulfated steroids. Sulfated steroids in the aqueous medium were then hydrolyzed with sulfatase and extracted with hexane. Each extract was analyzed separately. HPLC resolution combined with the sensitivity and specificity of MS/MS allowed quantification of DHEA, E2, and T with 10, 10, and 5 fmol lower limits of quantification and linear ranges to 1 pmol. Application of the method to mouse serum and tissues reveals ranges of DHEA, E2, and T and their sulfates, and tissue-specific differences in steroid profile, especially white versus brown adipose. In addition, marginal decreases of T in all tissues and considerable increases in DHEA in male iWAT and eWAT in response to a high-fat diet further strengthen the inference regarding the role of steroid metabolism in adipogenesis. This assay permits detailed studies of interactions between adiposity and sex steroids in serum and tissues, including adipose
Information Technology and Student Achievement: Evidence from a Randomized Experiment in Ecuador
This paper studies the effects of information and communication technologies (ICT) in the school environment on educational achievement. To quantify these effects, the impact is evaluated of a project run by the municipality of Guayaquil, Ecuador, which provides computer-aided instruction in mathematics and language to students in primary schools. Using an experimental design, it is found that the program had a positive impact on mathematics test scores (about 0.30 of a standard deviation) and a negative but statistically insignificant effect on language test scores. The impact is heterogeneous and is much larger for those students at the top of the achievement distribution.Information and communications technology, Education, Experimental design, Ecuador
Potential of atmospheric pressure chemical ionization source in gas chromatography tandem mass spectrometry for the screening of urinary exogenous androgenic anabolic steroids
The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid–liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H]+ or [M + H-2TMSOH]+ ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL−1. Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected.Ministry of Education and Science, Spain, in the project DEP2011-28573-C02-01/02
Generalitat Valenciana (Research Group of Excellence Prometeo II/2014/023; ISIC EnviFood 2012/016
Development of a high-throughput LC-APCI-MS method for the determination of 13 phytoestrogens (including gut microbial metabolites) in human urine and serum
Sebomic identification of sex- and ethnicity-specific variations in residual skin surface components (RSSC) for bio-monitoring or forensic applications
Background: “Residual skin surface components” (RSSC) is the collective term used for the superficial layer of sebum, residue of sweat, small quantities of intercellular lipids and components of natural moisturising factor present on the skin surface. Potential applications of RSSC include use as a sampling matrix for identifying biomarkers of disease, environmental exposure monitoring, and forensics (retrospective identification of exposure to toxic chemicals). However, it is essential to first define the composition of “normal” RSSC. Therefore, the aim of the current study was to characterise RSSC to determine commonalities and differences in RSSC composition in relation to sex and ethnicity. Methods: Samples of RSSC were acquired from volunteers using a previously validated method and analysed by high-pressure liquid chromatography–atmospheric pressure chemical ionisation–mass spectrometry (HPLC-APCI-MS). The resulting data underwent sebomic analysis. Results: The composition and abundance of RSSC components varied according to sex and ethnicity. The normalised abundance of free fatty acids, wax esters, diglycerides and triglycerides was significantly higher in males than females. Ethnicity-specific differences were observed in free fatty acids and a diglyceride. Conclusions: The HPLC-APCI-MS method developed in this study was successfully used to analyse the normal composition of RSSC. Compositional differences in the RSSC can be attributed to sex and ethnicity and may reflect underlying factors such as diet, hormonal levels and enzyme expression.Peer reviewedFinal Published versio
The Total Synthesis of (–)-Scabrolide A
The first total synthesis of the norcembranoid diterpenoid scabrolide A is disclosed. The route begins with the synthesis of two chiral pool-derived fragments, which undergo a convergent coupling to expediently introduce all 19 carbon atoms of the natural product. An intramolecular Diels–Alder reaction and an enone–olefin cycloaddition/fragmentation sequence are then employed to construct the fused [5–6–7] linear carbocyclic core of the molecule and complete the total synthesis
- …
