A novel corneal indentation device for comparison of corneal tangent modulus before and after FS-LASIK in vivo

Abstract

Background: Corneal refractive laser surgery is widely used to correct myopia and astigmatism due to its safety and effectiveness. However, postoperative changes in corneal biomechanics, such as corneal ectasia, can occur, necessitating a deeper understanding of these changes. Finite Element Analysis has shown promise in predicting surgical outcomes based on corneal biomechanics. Devices like the Ocular Response Analyser (ORA) and Corvis ST provide noninvasive ways to measure corneal biomechanics, aiding in the assessment of corneal behavior post-surgery. Young's modulus and tangent modulus are crucial parameters for describing corneal elasticity, but there is limited data on the changes in tangent modulus following Femtosecond Laser-Assisted LASIK (FS-LASIK) in humans. This study aimed to investigate the effect of FS-LASIK on the corneal tangent modulus using a novel corneal indentation device (CID). The study sought to explore changes in corneal tangent modulus after FS-LASIK, taking into account central corneal thickness (CCT) and corneal radius, to enhance our understanding of the biomechanical changes induced by this surgical procedure. Results: Sixty-six patients (66 eyes) underwent FS-LASIK, resulting in significant changes in CCT, corneal radius, and Goldmann intraocular pressure (GAT IOP) 6 months post-surgery (△CCT = − 88 ± 31 µm, △corneal radius = 0.81 ± 0.30 mm, △GAT IOP = − 3.2 ± 2.4 mmHg, p < 0.001) 6 months after surgery. However, corneal stiffness did not significantly change (△ = − 0.002 ± 0.011, p < 0.2). The corneal tangent modulus showed a significant increase post-surgery (△ = 0.263 ± 0.146, p < 0.001), exhibiting a negative correlation with CCT (r = − 0.68, P < 0.001) and a positive correlation with corneal radius (r = 0.71, P < 0.001). For each 1 mm increase in corneal radius, there was a 0.23 MPa increase in corneal modulus, and for every 100 µm reduction in corneal thickness, there was a 0.14 MPa increase in corneal modulus. Conclusions: The corneal tangent modulus, influenced by corneal radius and CCT, increased significantly following FS-LASIK. This study highlights the biomechanical changes induced by FS-LASIK, with implications for understanding corneal behavior post-surgery and its potential impact on patient outcomes

Similar works

Full text

thumbnail-image

Hong Kong University of Science and Technology Institutional Repository

redirect
Last time updated on 30/09/2025

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.