Background A 1-h algorithm based on high-sensitivity cardiac troponin T (hs-cTnT) testing at presentation and again 1 h thereafter has been shown to accurately rule out acute myocardial infarction. Objectives The goal of the study was to evaluate the diagnostic accuracy of the 1-h algorithm when supplemented with patient history and an electrocardiogram (ECG) (the extended algorithm) for predicting 30-day major adverse cardiac events (MACE) and to compare it with the algorithm using hs-cTnT alone (the troponin algorithm). Methods This prospective observational study enrolled consecutive patients presenting to the emergency department (ED) with chest pain, for whom hs-cTnT testing was ordered at presentation. Hs-cTnT results at 1 h and the ED physician’s assessments of patient history and ECG were collected. The primary outcome was an adjudicated diagnosis of 30-day MACE defined as acute myocardial infarction, unstable angina, cardiogenic shock, ventricular arrhythmia, atrioventricular block, cardiac arrest, or death of a cardiac or unknown cause. Results In the final analysis, 1,038 patients were included. The extended algorithm identified 60% of all patients for rule-out and had a higher sensitivity than the troponin algorithm (97.5% vs. 87.6%; p 10. Conclusions A 1-h combination algorithm allowed fast rule-out and rule-in of 30-day MACE in a majority of ED patients with chest pain and performed better than the troponin-alone algorithm