Plastic fibres as the only reinforcement for flat suspended slabs: Experimental investigation and numerical simulation

Abstract

This paper focuses on the study of the structural response of hyperstatic concrete flat suspended slabs reinforced only with structural plastic macro-fibres. First, the experimental program is described and then the results obtained are presented. The slabs tested maintained a high load level after cracking showing a ductile behaviour with great stress redistribution capacity. Next, the tests were simulated by means of a finite element software with constitutive models according to the specifications of RILEM and the Spanish Structural Concrete Code (EHE). The numerical results in terms of load/mid-span deflection were compared with the experimental results. The predictions provided by the codes and guideline models clearly overestimated the experimental results, which suggests the need to review the constitutive models used for plastic fibre-reinforced concretePeer ReviewedPostprint (published version

Similar works

Full text

thumbnail-image

UPCommons. Portal del coneixement obert de la UPC

redirect
Last time updated on 16/06/2016

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.