Location of Repository

Detection of Serum Antibodies to Ovine Progressive Pneumonia Virus in Sheep by Using a Caprine Arthritis-Encephalitis Virus Competitive-Inhibition Enzyme-Linked Immunosorbent Assay

By Lynn M. Herrmann, William P. Cheevers, Katherine L. Marshall, Travis C. McGuire, Melinda M. Hutton, Gregory S. Lewis and Donald P. Knowles

Abstract

A competitive-inhibition enzyme-linked immunosorbent assay (cELISA) for detection of antibodies to the surface envelope (SU) of caprine arthritis-encephalitis virus (CAEV) was recently reported (L. M. Herrmann, W. P. Cheevers, T. C. McGuire, D. Scott Adams, M. M. Hutton, W. G. Gavin, and D. P. Knowles, Clin. Diagn. Lab. Immunol. 10:267-271, 2003). The cELISA utilizes CAEV-63 SU captured on microtiter plates using the monoclonal antibody (MAb) F7-299 and measures competitive displacement of binding of the anti-CAEV MAb GPB 74A by goat serum. The present study evaluated the CAEV cELISA for detection of antibodies to ovine progressive pneumonia virus (OPPV) in sheep. Three hundred thirty-two sera were randomly selected from 21,373 sheep sera collected throughout the United States to determine the sensitivity and specificity of cELISA and agar gel immunodiffusion (AGID) based on immunoprecipitation (IP) of [35S]methionine-labeled OPPV antigens as a standard of comparison. A positive cELISA test was defined as >20.9 percent inhibition (% I) of MAb 74A binding based on two standard deviations above the mean % I of 191 IP-negative sheep sera. At this cutoff, there were 2 of 141 false-negative sera (98.6% sensitivity) and 6 of 191 false-positive sera (96.9% specificity). Sensitivity and specificity values for IP-monitored AGID were comparable to those for cELISA for 314 of 332 sera with unambiguous AGID results. Concordant results by cELISA and IP resolved 16 of the 18 sera that were indeterminate by AGID. Additional studies evaluated cELISA by using 539 sera from a single OPPV-positive flock. Based on IP of 36 of these sera, there was one false-negative by cELISA among 21 IP-positive sera (95.5% sensitivity) and 0 of 15 false-positives (100% specificity). We conclude that the CAEV cELISA can be applied to detection of OPPV antibodies in sheep with high sensitivity and specificity

Topics: Veterinary Immunology
Publisher: American Society for Microbiology
Year: 2003
DOI identifier: 10.1128/CDLI.10.5.862-865.2003
OAI identifier: oai:pubmedcentral.nih.gov:193903
Provided by: PubMed Central
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • http://dx.doi.org/10.1128/CDLI... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.