539 research outputs found

    Twin-free YBa2Cu3O7 films on (001) NdGaO3 showing isotropic electrical behaviour

    Get PDF
    Investigating the epitaxial nature of YBa2Cu3O7 films on NdGaO3 (001) by Rutherford backscattering (RBS) and X-ray diffraction (XRD) texture measurements we find that the films are almost single crystalline, in the sense that the a, b and c axes are uniquely defined with respect to those of NdGaO3. The crystalline perfection is, however, not reflected in the electrical properties of the films. Although we measure a Tc of 89.7 K, we did not observe the expected anisotropy in the resistivity. We interpret this to be due to Ga diffusion from the substrate into the film, which effectively blocks the chain conductivity

    A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems

    Get PDF
    Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate information on the prosthesis' structure and the surrounding environment, which can make development difficult without a finalized mechanical prototype. This paper presents a new framework for the development of electromyographic hand control systems, consisting of a prosthesis model based on the biomechanical structure of the human hand. The model's dynamic structure uses an ellipsoidal representation of the phalanges. Other features include underactuation in the fingers and thumb modeled with bond graphs, and a viscoelastic contact model. The model's functions are demonstrated by the execution of lateral and tripod grasps, and evaluated with regard to joint dynamics and applied forces. Finally, additions are suggested with which this model can be of use in mechanical design and patient training as well

    2,3-Dimethoxy-10-oxostrychnidinium 2-(2,4,6-trinitroanilino)benzoate monohydrate: a 1:1 proton-transfer salt of brucine with o-picraminobenzoic acid

    Get PDF
    In the structure of the 1:1 proton-transfer compound of brucine with 2-(2,4,6-trinitroanilino)benzoic acid C23H27N2O4+ . C13H7N4O8- . H~2~O, the brucinium cations form the classic undulating ribbon substructures through overlapping head-to-tail interactions while the anions and the three related partial water molecules of solvation (having occupancies of 0.73, 0.17 and 0.10) occupy the interstitial regions of the structure. The cations are linked to the anions directly through N-H...O(carboxyl) hydrogen bonds and indirectly by the three water molecules which form similar conjoint cyclic bridging units [graph set R2/4(8)] through O-H...O(carbonyl) and O(carboxyl) hydrogen bonds, giving a two-dimensional layered structure. Within the anion, intramolecular N-H...O(carboxyl) and N H...O(nitro) hydrogen bonds result in the benzoate and picrate rings being rotated slightly out of coplanarity inter-ring dihedral angle 32.50(14)\%]. This work provides another example of the molecular selectivity of brucine in forming stable crystal structures and also represents the first reported structure of any form of the guest compound 2-(2,4,6-trinitroanilino)benzoic acid

    Myoelectric forearm prostheses: State of the art from a user-centered perspective

    Get PDF
    User acceptance of myoelectric forearm prostheses is currently low. Awkward control, lack of feedback, and difficult training are cited as primary reasons. Recently, researchers have focused on exploiting the new possibilities offered by advancements in prosthetic technology. Alternatively, researchers could focus on prosthesis acceptance by developing functional requirements based on activities users are likely to perform. In this article, we describe the process of determining such requirements and then the application of these requirements to evaluating the state of the art in myoelectric forearm prosthesis research. As part of a needs assessment, a workshop was organized involving clinicians (representing end users), academics, and engineers. The resulting needs included an increased number of functions, lower reaction and execution times, and intuitiveness of both control and feedback systems. Reviewing the state of the art of research in the main prosthetic subsystems (electromyographic [EMG] sensing, control, and feedback) showed that modern research prototypes only partly fulfill the requirements. We found that focus should be on validating EMG-sensing results with patients, improving simultaneous control of wrist movements and grasps, deriving optimal parameters for force and position feedback, and taking into account the psychophysical aspects of feedback, such as intensity perception and spatial acuity

    Mechanical design and control of a new myoelectric hand prosthesis

    Get PDF
    The development of modern, myoelectrically controlled hand prostheses can be difficult, due to the many requirements its mechanical design and control system need to fulfill [1]. The hand should be controllable with few input signals, while being able to perform a wide range of motions. It should be lightweight and slim, but be able to actuate all fingers separately. To accomplish this, new control and mechanical design techniques are implemented in a modern hand prosthesis prototype

    Hoe het placebo-effect kan bijdragen aan een betere gezondheidszorg

    Get PDF
    FSW - Self-regulation models for health behavior and psychopathology - ou
    corecore