109 research outputs found

    The evolution of radiological measurements and the association with clinician and patient reported outcome following distal radius fractures in non-osteoporotic patients:what is clinically relevant?

    Get PDF
    Introduction: Following distal radius fractures in young non-osteoporotic patients, clinical relevancy of outcome has been scarcely reported. Outcome can be put in perspective by using measurement errors of radiological measurements and Minimal Important Change when reporting on clinician and patient reported outcome. Aim of this study was to assess the clinical relevance of radiological measurements, clinician and patient reported outcomes following distal radius fractures in young non-osteoporotic patients.Methods: Retrospective cohort study. Non-osteoporotic patients following a distal radius fracture were selected. Radiographs of both wrists were obtained at baseline, 6 weeks and at follow-up. Active range of motion and grip strength measurements were obtained at the follow-up visit and 4 questionnaires were answered to assess pain, upper extremity functioning, and health status.Results: Seventy-three patients (32 women, 41 men) with a mean age of 33.5 (SD 9.2) years at the time of injury were included. Median follow up was 62 months (IQR 53.0-84.5). Several radiological measurements evolved statistically significantly over time, however none exceeded measurement errors. Flexion/extension difference of injured compared to uninjured wrist (mean difference 11.2°, t = -7.5, df = 72, p < 0.001), exceeded Minimal Important Change, while grip strength differences did not. When comparing patients with DRFs to healthy controls, only the differences on Patient Reported Wrist Evaluation subscales "pain", "function" and total scores exceeded minimal important change (8, 10 and 13 points, respectively). Multivariable regression analysis revealed statistically significant relationships between residual step-off and respectively diminished flexion/extension (B = -36.8, 95% CI -62; -11.1, p  =  0.006), diminished radial/ulnar deviation (B = -17.9, 95% CI -32.0; -3.9, p  =  0.013) and worse ShortForm-36 "mental component score" (B = -15.4, 95% CI -26.6; -4.2, p < 0.001).Conclusion: Radiological measurements following distal radius fractures seem to evolve over time, but differences were small and were probably not clinically relevant. Range of motion, in particular flexion/extension, was impaired to such extend that it was noticeable for a patient, whereas grip strength was not impaired. The Patient Reported Wrist Evaluation was clinically relevantly diminished. Residual articular incongruency seems to influence range of motion.Implications for rehabilitationReporting Minimal Important Change regarding clinician and patient reported outcome following distal radius fractures is of more clinical value than reporting on statistical significance.Following distal radius fractures, the changes in radiological measurements do not seem to reflect a clinical relevant change.Range of motion, in particular flexion/extension, should be measured following distal radius fractures, as this might be impaired in a clinically relevant way.Measuring grip strength is of less importance following distal radius fractures, because grip strength does not seem to be affected.Residual articular incongruency seems to influence range of motion and therefore should be reduced to a minimum when treating non-osteoporotic patients

    Nonoperatively treated type A spinal fractures:mid-term versus long-term functional outcome

    Get PDF
    This study focuses on the mid-term (four years) and long-term (ten years) functional outcome of patients treated nonoperatively for a type A spinal fracture without primary neurological deficit. Functional outcome was measured using the visual analogue scale spine score (VAS) and the Roland–Morris disability questionnaire (RMDQ). The 50 patients included were on average 41.2 years old at the time of injury. Four years post injury, a mean VAS score of 74.5 and a mean RMDQ score of 4.9 were found. Ten years after the accident, the mean VAS and RMDQ scores were 72.6 and 4.7, respectively (NS). No significant relationships were found between the difference scores of the VAS and RMDQ compared with age, gender, fracture sub-classification, and time between measurements. Three (6%) patients had a poor long-term outcome. None of the patients required surgery for late onset pain or progressive neurological deficit. Functional outcome after a nonoperatively treated type A spinal fracture is good, both four and ten years post injury. For the group as a whole, four years after the fracture a steady state exists in functional outcome, which does not change for ten years at least after the fracture

    What Are the Interobserver and Intraobserver Variability of Gap and Stepoff Measurements in Acetabular Fractures?

    Get PDF
    BACKGROUND: Gap and stepoff values in the treatment of acetabular fractures are correlated with clinical outcomes. However, the interobserver and intraobserver variability of gap and stepoff measurements for all imaging modalities in the preoperative, intraoperative, and postoperative phase of treatment is unknown. Recently, a standardized CT-based measurement method was introduced, which provided the opportunity to assess the level of variability. QUESTIONS/PURPOSES: (1) In patients with acetabular fractures, what is the interobserver variability in the measurement of the fracture gaps and articular stepoffs determined by each observer to be the maximum one in the weightbearing dome, as measured on pre- and postoperative pelvic radiographs, intraoperative fluoroscopy, and pre- and postoperative CT scans? (2) What is the intraobserver variability in these measurements? METHODS: Sixty patients with a complete subset of pre-, intra- and postoperative high-quality images (CT slices of < 2 mm), representing a variety of fracture types with small and large gaps and/or stepoffs, were included. A total of 196 patients with nonoperative treatment (n = 117), inadequate available imaging (n = 60), skeletal immaturity (n = 16), bilateral fractures (n = 2) or a primary THA (n = 1) were excluded. The maximum gap and stepoff values in the weightbearing dome were digitally measured on pelvic radiographs and CT images by five independent observers. Observers were free to decide which gap and/or stepoff they considered the maximum and then measure these before and after surgery. The observers were two trauma surgeons with more than 5 years of experience in pelvic surgery, two trauma surgeons with less than 5 years of experience in pelvic surgery, and one surgical resident. Additionally, the final intraoperative fluoroscopy images were assessed for the presence of a gap or stepoff in the weightbearing dome. All observers used the same standardized measurement technique and each observer measured the first five patients together with the responsible researcher. For 10 randomly selected patients, all measurements were repeated by all observers, at least 2 weeks after the initial measurements. The intraclass correlation coefficient (ICC) for pelvic radiographs and CT images and the kappa value for intraoperative fluoroscopy measurements were calculated to determine the inter- and intraobserver variability. Interobserver variability was defined as the difference in the measurements between observers. Intraobserver variability was defined as the difference in repeated measurements by the same observer. RESULTS: Preoperatively, the interobserver ICC was 0.4 (gap and stepoff) on radiographs and 0.4 (gap) and 0.3 (stepoff) on CT images. The observers agreed on the indication for surgery in 40% (gap) and 30% (stepoff) on pelvic radiographs. For CT scans the observers agreed in 95% (gap) and 70% (stepoff) of images. Postoperatively, the interobserver ICC was 0.4 (gap) and 0.2 (stepoff) on radiographs. The observers agreed on whether the reduction was acceptable or not in 60% (gap) and 40% (stepoff). On CT images the ICC was 0.3 (gap) and 0.4 (stepoff). The observers agreed on whether the reduction was acceptable in 35% (gap) and 38% (stepoff). The preoperative intraobserver ICC was 0.6 (gap and stepoff) on pelvic radiographs and 0.4 (gap) and 0.6 (stepoff) for CT scans. Postoperatively, the intraobserver ICC was 0.7 (gap) and 0.1 (stepoff) on pelvic radiographs. On CT the intraobserver ICC was 0.5 (gap) and 0.3 (stepoff). There was no agreement between the observers on the presence of a gap or stepoff on intraoperative fluoroscopy images (kappa -0.1 to 0.2). CONCLUSIONS: We found an insufficient interobserver and intraobserver agreement on measuring gaps and stepoffs for supporting clinical decisions in acetabular fracture surgery. If observers cannot agree on the size of the gap and stepoff, it will be challenging to decide when to perform surgery and study the results of acetabular fracture surgery. LEVEL OF EVIDENCE: Level III, diagnostic study

    The Dutch nationwide trauma registry:The value of capturing all acute trauma admissions

    Get PDF
    Introduction: Twenty years ago the Dutch trauma care system was reformed by the designating 11 level one Regional trauma centres (RTCs) to organise trauma care. The RTCs set up the Dutch National Trauma Registry (DNTR) to evaluate epidemiology, patient distribution, resource use and quality of care. In this study we describe the DNTR, the incidence and main characteristics of Dutch acutely admitted trauma patients, and evaluate the value of including all acute trauma admissions compared to more stringent criteria applied by the national trauma registries of the United Kingdom and Germany. Methods: The DNTR includes all injured patients treated at the ED within 48 hours after trauma and consecutively followed by direct admission, transfers to another hospital or death at the ED. DNTR data on admission years 2007-2018 were extracted to describe the maturation of the registry. Data from 2018 was used to describe the incidence rate and patient characteristics. Inclusion criteria of the Trauma Audit and Research (TARN) and the Deutsche Gesellschaft für Unfallchirurgie (DGU) were applied on 2018 DNTR data. Results: Since its start in 2007 a total of 865,460 trauma cases have been registered in the DNTR. Hospital participation increased from 64% to 98%. In 2018, a total of 77,529 patients were included, the median age was 64 years, 50% males. Severely injured patients with an ISS≥16, accounted for 6% of all admissions, of which 70% was treated at designated RTCs. Patients with an ISS≤ 15were treated at non-RTCs in 80% of cases. Application of DGU or TARN inclusion criteria, resulted in inclusion of respectively 5% and 32% of the DNTR patients. Particularly children, elderly and patients admitted at non-RTCs are left out. Moreover, 50% of ISS≥16 and 68% of the fatal cases did not meet DGU inclusion criteria Conclusion: The DNTR has evolved into a comprehensive well-structured nationwide population-based trauma register. With 80,000 inclusions annually, the DNTR has become one of the largest trauma databases in Europe The registries strength lies in the broad inclusion criteria which enables studies on the burden of injury and the quality and efficiency of the entire trauma care system, encompassing all trauma‐receiving hospitals

    Quantitative 3D measurements of tibial plateau fractures

    Get PDF
    Fracture gap and step-off measurements on 2DCT-slices probably underestimate the complex multi-directional features of tibial plateau fractures. Our aim was to develop a quantitative 3D-CT (Q3DCT) fracture analysis of these injuries. CT-based 3D models were created for 10 patients with a tibial plateau fracture. Several 3D measures (gap area, articular surface involvement, 3D displacement) were developed and tested. Gaps and step-offs were measured in 2D and 3D. All measurements were repeated by six observers and the reproducibility was determined by intra-class correlation coefficients. Q3DCT measurements demonstrated a median gap of 5.3 mm, step-off of 5.2 mm, gap area of 235 mm2, articular surface involvement of 33% and 3D displacement of 6.1 mm. The inter-rater reliability was higher in the Q3DCT than in the 2DCT measurements for both the gap (0.96 vs. 0.81) and step-off (0.63 vs. 0.32). Q3DCT measurements showed excellent reliability (ICC of 0.94 for gap area, 1 for articular surface involvement and 0.99 for 3D displacement). Q3DCT fracture analysis of tibial plateau fractures is feasible and shows excellent reliability. 3D measurements could be used together with the current classification systems to quantify the true extent of these complex multi-directional fractures in a standardized way
    corecore