23 research outputs found

    Intraventricular Septation in the Context of Dilated Cardiomyopathy Associated With TTN Mutation

    Get PDF
    A 6-month-old infant boy presented with symptomatic heart failure. Dilated cardiomyopathy was found in association with a mutation in TTN. Structural heart disease included novel septation of the left ventricle with a fenestrated membrane resulting from aberrant congenital mitral valve apparatus formation. (Level of Difficulty: Advanced.)

    Detection of retained microbubbles in carotid arteries with real-time low mechanical index imaging in the setting of endothelial dysfunction

    Get PDF
    ObjectivesWe sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS).BackgroundMicrobubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles.MethodsIntravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified.ResultsAfter induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells.ConclusionsRetention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS

    Prevention of arteriovenous shunt occlusion using microbubble and ultrasound mediated thromboprophylaxis.

    Get PDF
    BACKGROUND: Palliative shunts in congenital heart disease patients are vulnerable to thrombotic occlusion. High mechanical index (MI) impulses from a modified diagnostic ultrasound (US) transducer during a systemic microbubble (MB) infusion have been used to dissolve intravascular thrombi without anticoagulation, and we sought to determine whether this technique could be used prophylactically to reduce thrombus burden and prevent occlusion of surgically placed extracardiac shunts. METHODS AND RESULTS: Heparin-bonded ePTFE tubular vascular shunts of 4 mmĂ—2.5 cm (Propaten; W.L Gore) were surgically placed in 18 pigs: a right-sided side-to-side arteriovenous (AV, carotid-jugular) shunt, and a left-sided arterio-arterial (AA, carotid-carotid) interposition shunt in each animal. After shunt implantation, animals were randomly assigned to one of 3 groups. Transcutaneous, weekly 30-minute treatments (total of 4 treatments) of either guided high MI US+MB (Group 1; n=6) using a 3% MRX-801 MB infusion, or US alone (Group 2; n=6) were given separately to each shunt. The third group of 6 pigs received no treatments. The shunts were explanted after 4 weeks and analyzed by histopathology to quantify luminal thrombus area (mm2) for the length of each shunt. No pigs received antiplatelet agents or anticoagulants during the treatment period. The median overall thrombus burden in the 3 groups for AV shunts was 5.10 mm2 compared with 4.05 mm(2) in AA (P=0.199). Group 1 pigs had significantly less thrombus burden in the AV shunts (median 2.5 mm2) compared with Group 2 (median 5.6 mm2) and Group 3 (median 7.5 mm2) pigs (P=0.006). No difference in thrombus burden was seen between groups for AA shunts. CONCLUSION: Transcutaneous US with intravenous MB is capable of preventing thrombus accumulation in arteriovenous shunts without the need for antiplatelet agents, and may be a method of preventing progressive occlusion of palliative shunts

    Microbubble mediated thrombus dissolution with diagnostic ultrasound for the treatment of chronic venous thrombi.

    Get PDF
    BACKGROUND: Central venous catheter (CVC) thrombi result in significant morbidity in children, and currently available treatments are associated with significant risk. We sought to investigate the therapeutic efficacy of microbubble (MB) enhanced sonothrombolysis for aged CVC associated thrombi in vivo. METHODS AND RESULTS: A model of chronic indwelling CVC in the low superior vena cava with thrombus in situ was established after feasibility and safety testing in 7 pigs; and subsequently applied for repeated, sonothrombolytic treatments in 9 pigs (total 24 treatments). Baseline intracardiac echocardiography (ICE, 10.5F, Siemens), fluoroscopy and saline flushing confirmed the absence of any pre-existing CVC thrombus. A thrombus was then allowed to form and age over 24 hours. The created thrombus was localized and measured by ICE, and transthoracic image guided high mechanical index (MI) two-dimensional US treatments (1.1-1.7 MI; iE33, Philips) applied intermittently whenever intravenously infused MBs (3% MRX-801; NuVox) were visualized near the thrombus (n = 10; Group A). Control pigs (n = 10; Group B) received US without MB. All treatments were randomized. Post-treatment thrombus area by ICE planimetry was compared with pre-treatment measurements. Thrombus area measurements before and after treatment were 0.22 and 0.10 cm(2) respectively in Group A; compared to 0.24 and 0.21 cm(2) in Group B (p  = 0.0003). Effectiveness of longer duration US and MB thrombolytic treatments were studied (n = 4), which suggested that near complete thrombus dissolution is possible. No pulmonary emboli, alterations in oxygen saturation, or hemodynamics occurred with either treatment. CONCLUSIONS: Guided high MI diagnostic US+systemic MB facilitates reduction of aged CVC associated thrombi in vivo. MB enhanced sonothrombolytic therapy may be a non-invasive safe alternative to thrombolytic agents in treating thrombotic CVC occlusions

    Autoimmune Hepatitis Induced by Syngeneic Liver Cytosolic Proteins Biotransformed by Alcohol Metabolites

    Get PDF
    Aldehydes that are produced following the breakdown of ethanol (acetaldehyde) and lipid peroxidation of membranes (malondialdehyde) have been shown to bind (adduct) proteins. Additionally, these two aldehydes can combine (MAA) on non-syngeneic and syngeneic proteins to initiate numerous immune responses to the unmodified part of the protein in the absence of an adjuvant. Therefore, these studies provide a potential mechanism for the development of antigen-specific immune responses resulting in liver damage should syngeneic liver proteins be adducted with MAA

    Consensus statement on surgical pathology of the aorta from the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology: I. Inflammatory diseases

    Get PDF
    Abstract Inflammatory diseases of the aorta include routine atherosclerosis, aortitis, periaortitis, and atherosclerosis with excessive inflammatory responses, such as inflammatory atherosclerotic aneurysms. The nomenclature and histologic features of these disorders are reviewed and discussed. In addition, diagnostic criteria are provided to distinguish between these disorders in surgical pathology specimens. An initial classification scheme is provided for aortitis and periaortitis based on the pattern of the inflammatory infiltrate: granulomatous/giant cell pattern, lymphoplasmacytic pattern, mixed inflammatory pattern, and the suppurative pattern. These inflammatory patterns are discussed in relation to specific systemic diseases including giant cell arteritis, Takayasu arteritis, granulomatosis with polyangiitis (Wegener's), rheumatoid arthritis, sarcoidosis, ankylosing spondylitis, Cogan syndrome, Behcet's disease, relapsing polychondritis, syphilitic aortitis, and bacterial and fungal infections

    Utilization of virtual microscopy in cytotechnology educational programs in the United States

    No full text
    Background: Our cytotechnology (CT) program has been utilizing virtual microscopy (VM) as an adjunct educational resource since 2011. Aims: The aim of this study was to identify the utilization of VM in other CT programs across the United States (US). Subjects and Methods: A cover letter was sent to the program directors of all accredited CT programs in the US (excluding our program), requesting their participation in an online survey. After 2 days, the participants were sent an online link to the survey. The survey results were analyzed using descriptive statistics. Results: There were a total of 25 respondents to the survey. Among the 25, three CT programs use VM. Two of the three programs have been using VM for <2 years while another program for "2-4" years. The respondents found that VM′s side-by-side comparison feature helped to demonstrate differences between diagnoses and preparation methods, and VM helped to preserve the important slides by digitizing them. Respondents believed that teaching with glass slides was very important. The reasons for not using VM were that VM is expensive and time-consuming to incorporate into the program, and lack of manpower resources to create digitized teaching files. Conclusions: The CT programs that use VM found it to be a valuable educational tool. Even though many were not using VM, responses from the survey indicated they will likely use it in the future

    Investigation of scanning parameters for thyroid fine needle aspiration cytology specimens: A pilot study

    No full text
    Background: Interest in developing more feasible and affordable applications of virtual microscopy in the field of cytology continues to grow. Aims: The aim of this study was to investigate the scanning parameters for the thyroid fine needle aspiration (FNA) cytology specimens. Subjects and Methods: A total of twelve glass slides from thyroid FNA cytology specimens were digitized at ×40 with 1 micron (μ) interval using seven focal plane (FP) levels (Group 1), five FP levels (Group 2), and three FP levels (Group 3) using iScan Coreo Au scanner (Ventana, AZ, USA) producing 36 virtual images (VI). With an average wash out period of 2 days, three participants diagnosed the preannotated cells of Groups 1, 2, and 3 using BioImagene′s Image Viewer (version 3.1) (Ventana, Inc., Tucson, AZ, USA), and the corresponding 12 glass slides (Group 4) using conventional light microscopy. Results: All three raters correctly identified and showed complete agreement on the glass and VI for: 86% of the cases at FP Level 3, 83% of the cases at both the FP Levels 5 and 7. The intra-observer concordance between the glass slides and VI for all three raters was highest (97%) for Level 3 and glass, same (94%) for Level 5 and glass; and Level 7 and glass. The inter-rater reliability was found to be highest for the glass slides, and three FP levels (77%), followed by five FP levels (69.5%), and seven FP levels (69.1%). Conclusions: This pilot study found that among the three different FP levels, the VI digitized using three FP levels had slightly higher concordance, intra-observer concordance, and inter-rater reliability. Scanning additional levels above three FP levels did not improve concordance. We believe that there is no added benefit of acquiring five FP levels or more especially when considering the file size, and storage costs. Hence, this study reports that FP level three and 1 μ could be the potential scanning parameters for the thyroid FNA cytology specimens
    corecore