4,124 research outputs found

    Matrix effects in ion-induced emission as observed in Ne collisions with Cu-Mg and Cu-Al alloys

    Get PDF
    Ion induced Auger electron emission is used to study the surfaces of Al, Mg, Cu - 10 at. % Al, Cu - 19.6 at. % Al, and Cu - 7.4 at. % Mg. A neon (Ne) ion beam whose energy is varied from 0.5 to 3 keV is directed at the surface. Excitation of the lighter Ne occurs by the promotion mechanism of Barat and Lichten in asymmetric collisions with Al or Mg atoms. Two principal Auger peaks are observed in the Ne spectrum: one at 22 eV and one at 25 eV. Strong matrix effects are observed in the alloys as a function of energy in which the population of the second peak is greatly enhanced relative to the first over the pure materials. For the pure material over this energy range this ratio is 1.0. For the alloys it can rise to the electronic structure of alloys and to other surface tools such as secondary ion mass spectroscopy

    Thickness of the rim of an expanding lamella near the splash threshold

    Get PDF
    The evolution of the ejected liquid sheet, or lamella, created after impact of a liquid drop onto a solid surface is studied using high-speed video in order to observe the detailed time evolution of the thickness of the rim of the lamella. Since it has been suggested that splashing behavior is set at very early times after impact, we study early times up to D-0/U-0, where D-0 and U-0 are the diameter and speed of the impacting drop, respectively, for different liquid viscosities and impact speeds below the splashing threshold. Within the regime of our experiments, our results are not consistent with the idea that the lamella rim grows similar to the boundary layer thickness. Rather, we find that the rim thickness is always much larger than the boundary layer thickness, and that the rim thickness decreases with increasing impact speed. For lower impact speeds, the increase in the rim thickness is consistent with a root t response over the limited time range available, but the dependence is not simply proportional to root nu, where nu is the kinematic viscosity, and there is a strong dependence of the rim thickness on the impact speed U-0. Scaling of the rim height using a balance of inertial and surface tension forces provides some collapse of the data at lower impact speeds. We also observe an unusual plateau behavior in thickness versus time at higher impact speeds as we approach the splash threshold. (C) 2010 American Institute of Physics. [doi:10.1063/1.3313360

    Time-reversal in dynamically-tuned zero-gap periodic systems

    Full text link
    We show that short pulses propagating in zero-gap periodic systems can be reversed with 100% efficiency by using weak non-adiabatic tuning of the wave velocity at time-scales that can be much slower than the period. Unlike previous schemes, we demonstrate reversal of {\em broadband} (few cycle) pulses with simple structures. Our scheme may thus open the way to time-reversal in a variety of systems for which it was not accessible before.Comment: Accepted for publication in Phys. Rev. Letter

    Upper-division Student Understanding of Coulomb's Law: Difficulties with Continuous Charge Distributions

    Full text link
    Utilizing the integral expression of Coulomb's Law to determine the electric potential from a continuous charge distribution is a canonical exercise in Electricity and Magnetism (E&M). In this study, we use both think-aloud interviews and responses to traditional exam questions to investigate student difficulties with this topic at the upper-division level. Leveraging a theoretical framework for the use of mathematics in physics, we discuss how students activate, construct, execute and reflect on the integral form of Coulomb's Law when solving problems with continuous charge distributions. We present evidence that junior-level E&M students have difficulty mapping physical systems onto the mathematical expression for the Coulomb potential. Common challenges include difficulty expressing the difference vector in appropriate coordinates as well as determining expressions for the differential charge element and limits of integration for a specific charge distribution. We discuss possible implications of these findings for future research directions and instructional strategies.Comment: 5 pages, 1 figure, 2 tables, accepted to 2012 PERC Proceeding

    Newly shaped intra-aortic balloons improve the performance of counterpulsation at the semirecumbent position: an In Vitro study

    Get PDF
    The major hemodynamic benefits of intra‐aortic balloon pump (IABP) counterpulsation are augmentation in diastolic aortic pressure (Paug) during inflation, and decrease in end‐diastolic aortic pressure (ΔedP) during deflation. When the patient is nursed in the semirecumbent position these benefits are diminished. Attempts to change the shape of the IAB in order to limit or prevent this deterioration have been scarce. The aim of the present study was to investigate the hemodynamic performance of six new IAB shapes, and compare it to that of a traditional cylindrical IAB. A mock circulation system, featuring an artificial left ventricle and an aortic model with 11 branches and physiological resistance and compliance, was used to test one cylindrical and six newly shaped IABs at angles 0, 10, 20, 30, and 40°. Pressure was measured continuously at the aortic root during 1:1 and 1:4 IABP support. Shape 2 was found to consistently achieve, in terms of absolute magnitude, larger ΔedP at angles than the cylindrical IAB. Although ΔedP was gradually diminished with angle, it did so to a lesser degree than the cylindrical IAB; this diminishment was only 53% (with frequency 1:1) and 40% (with frequency 1:4) of that of the cylindrical IAB, when angle increased from 0 to 40°. During inflation Shape 1 displayed a more stable behavior with increasing angle compared to the cylindrical IAB; with an increase in angle from 0 to 40°, diastolic aortic pressure augmentation dropped only by 45% (with frequency 1:1) and by 33% (with frequency 1:4) of the drop reached with the cylindrical IAB. After compensating for differences in nominal IAB volume, Shape 1 generally achieved higher Paug over most angles. Newly shaped IABs could allow for IABP therapy to become more efficient for patients nursed at the semirecumbent position. The findings promote the idea of personalized rather than generalized patient therapy for the achievement of higher IABP therapeutic efficiency, with a choice of IAB shape that prioritizes the recovery of those hemodynamic indices that are more in need of support in the unassisted circulation
    corecore