22 research outputs found

    The Changing Landscape for Stroke\ua0Prevention in AF: Findings From the GLORIA-AF Registry Phase 2

    Get PDF
    Background GLORIA-AF (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation) is a prospective, global registry program describing antithrombotic treatment patterns in patients with newly diagnosed nonvalvular atrial fibrillation at risk of stroke. Phase 2 began when dabigatran, the first non\u2013vitamin K antagonist oral anticoagulant (NOAC), became available. Objectives This study sought to describe phase 2 baseline data and compare these with the pre-NOAC era collected during phase 1. Methods During phase 2, 15,641 consenting patients were enrolled (November 2011 to December 2014); 15,092 were eligible. This pre-specified cross-sectional analysis describes eligible patients\u2019 baseline characteristics. Atrial fibrillation disease characteristics, medical outcomes, and concomitant diseases and medications were collected. Data were analyzed using descriptive statistics. Results Of the total patients, 45.5% were female; median age was 71 (interquartile range: 64, 78) years. Patients were from Europe (47.1%), North America (22.5%), Asia (20.3%), Latin America (6.0%), and the Middle East/Africa (4.0%). Most had high stroke risk (CHA2DS2-VASc [Congestive heart failure, Hypertension, Age  6575 years, Diabetes mellitus, previous Stroke, Vascular disease, Age 65 to 74 years, Sex category] score  652; 86.1%); 13.9% had moderate risk (CHA2DS2-VASc = 1). Overall, 79.9% received oral anticoagulants, of whom 47.6% received NOAC and 32.3% vitamin K antagonists (VKA); 12.1% received antiplatelet agents; 7.8% received no antithrombotic treatment. For comparison, the proportion of phase 1 patients (of N = 1,063 all eligible) prescribed VKA was 32.8%, acetylsalicylic acid 41.7%, and no therapy 20.2%. In Europe in phase 2, treatment with NOAC was more common than VKA (52.3% and 37.8%, respectively); 6.0% of patients received antiplatelet treatment; and 3.8% received no antithrombotic treatment. In North America, 52.1%, 26.2%, and 14.0% of patients received NOAC, VKA, and antiplatelet drugs, respectively; 7.5% received no antithrombotic treatment. NOAC use was less common in Asia (27.7%), where 27.5% of patients received VKA, 25.0% antiplatelet drugs, and 19.8% no antithrombotic treatment. Conclusions The baseline data from GLORIA-AF phase 2 demonstrate that in newly diagnosed nonvalvular atrial fibrillation patients, NOAC have been highly adopted into practice, becoming more frequently prescribed than VKA in Europe and North America. Worldwide, however, a large proportion of patients remain undertreated, particularly in Asia and North America. (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients With Atrial Fibrillation [GLORIA-AF]; NCT01468701

    Adaptive Smolyak Pseudospectral Approximations

    No full text
    Polynomial approximations of computationally intensive models are central to uncertainty quantification. This paper describes an adaptive method for non-intrusive pseudospectral approximation, based on Smolyak's algorithm with generalized sparse grids. We rigorously analyze and extend the non-adaptive method proposed in [6], and compare it to a common alternative approach for using sparse grids to construct polynomial approximations, direct quadrature. Analysis of direct quadrature shows that O(1) errors are an intrinsic property of some configurations of the method, as a consequence of internal aliasing. We provide precise conditions, based on the chosen polynomial basis and quadrature rules, under which this aliasing error occurs. We then establish theoretical results on the accuracy of Smolyak pseudospectral approximation, and show that the Smolyak approximation avoids internal aliasing and makes far more effective use of sparse function evaluations. These results are applicable to broad choices of quadrature rule and generalized sparse grids. Exploiting this flexibility, we introduce a greedy heuristic for adaptive refinement of the pseudospectral approximation. We numerically demonstrate convergence of the algorithm on the Genz test functions, and illustrate the accuracy and efficiency of the adaptive approach on a realistic chemical kinetics problem

    Marked prolongation of QRS duration after initiation of dronedarone therapy

    No full text
    Dronedarone is a relatively new antiarrhythmic drug and is held to be less proarrhythmic than comparable compounds, although its proarrhythmia potential in humans has not been sufficiently evaluated. We describe a so far unreported dronedarone effect, namely a significant alteration of both the morphology and the duration of the QRS complex on the electro cardiogram in a 41-year old patient with symptomatic paroxysmal atrial fibrillation

    Left atrial enlargement and clinical considerations in patients with or without a residual interatrial shunt after closure of the left atrial appendage with the WATCHMAN™-device

    No full text
    Abstract Background Interventional closure of the left atrial appendage (LAA) in patients with non-valvular atrial fibrillation, high thromboembolic and bleeding risk or bleeding history is an alternative therapeutic strategy to oral anticoagulation. It is not known if the exclusion of the LAA from the blood circulation affects the left atrial volume (LAV) and consequently its prognostic value or the circulatory performance of the heart in humans. Methods We aimed to prospectively assess potential changes in baseline LAV, left ventricular ejection fraction (LVEF), NT-proBNP-level and the covered distance in the 6-min walk-test 6 weeks and 6 months after LAA closure with the WATCHMAN™ device. We used serial 3-dimensional transthoracic and transesophageal echocardiography to assess LAV, residual interatrial shunt and device performance in 58 consecutive patients with successful LAA closure. Results Accurate 3D–echocardiographic data for LAV measurements were evaluable for 51 (91%) patients. Maximum LAV (LAVmax) at baseline was 102.8 ± 30.8 ml and increased significantly to 107.7 ± 32.8 ml after 6 weeks (p < 0.01) and 113.5 ± 34.2 ml after 6 months (p < 0.01). Minimal LAV (LAVmin) increased from 76.9 ± 29.5 ml at baseline to 81.8 ± 30.2 ml after 45 days (p < 0.01) and 82.1 ± 33.3 ml after 6 months (p < 0.01). Similarly, their indexes to BSA (LAVImax and LAVImin) increased significantly, as well. Patients without a residual left-to-right interatrial shunt showed a significantly higher increase in LAVmax or LAVmin. Baseline LVEF, NT-proBNP-level or the distance covered at the 6-min walk test did not significantly change 6 weeks or 6 months after LAA closure. Conclusions LAVmax and LAVmin increase significantly after interventional LAA closure. LA enlargement does not correlate with clinical progression of heart failure. Persistent left-to-right interatrial shunt counteracts the LA enlargement. A reduced LA compliance after exclusion of the LAA from the blood circulation with consecutive increase in LA pressure may be a potential cause of LA enlargement and warrants further investigation. Trial registration German Clinical Trials Register ID: DRKS00010768 ; Registration Date 07.07.2016

    Catheter navigation by intracardiac echocardiography enables zero-fluoroscopy linear lesion formation and bidirectional cavotricuspid isthmus block in patients with typical atrial flutter

    No full text
    Abstract Introduction One of the most helpful aspects of intracardiac echocardiography (ICE) implementation in electrophysiological studies (EPS) is the real-time visualisation of catheters and cardiac structures. In this prospective study, we investigated ICE-guided zero-fluoroscopy catheter navigation during radiofrequency (RF) ablation of the cavotricuspid isthmus (CTI) in patients with typical atrial flutter (AFL). Methods and results Thirty consecutive patients (mean age 72.9 ± 11.4 years, 23 male) with ongoing (n = 23) or recent CTI-dependent AFL underwent an EPS, solely utilizing ICE for catheter navigation. Zero-fluoroscopy EPS could be successfully accomplished in all patients. Mean EPS duration was 41.4 ± 19.9 min, and mean ablation procedure duration was 20.8 ± 17.1 min. RF ablation was applied for 6.0 ± 3.1 min (50W, irrigated RF ablation). Echocardiographic parameters, such as CTI length, prominence of the Eustachian ridge (ER), and depth of the CTI pouch on the ablation plane, were assessed to analyse their correlation with EPS- or ablation procedure duration. The CTI pouch was shallower in patients with an ablation procedure duration above the median (4.8 ± 1.1 mm vs. 6.4 ± 0.9 mm, p = 0.04), suggesting a more lateral ablation plane in these patients, where the CTI musculature is stronger. CTI length or ER prominence above the respective median did not correlate with longer EPS duration. Conclusions Zero-fluoroscopy CTI ablation guided solely by intracardiac echocardiography in patients with CTI-dependent AFL is feasible and safe. ICE visualisation may help to localise the optimal ablation plane, detect and correct poor tissue contact of the catheter tip, and recognise early potential complications during the ablation procedure. Graphical Abstrac

    Settlement Patterns in the Southern Levant Deserts During the 6th–3rd Millennia BC: a Revision Based on 14

    No full text
    From the 17th International Radiocarbon Conference held in Jerusalem, Israel, June 18-23, 2000.Archaeological surveys conducted in the Negev and Sinai during the 20th century were commonly interpreted as representing short settlement periods interrupted by long gaps. The time factor was usually based on archaeological estimates rather than comprehensive physical dating. For example, the perceived age and time duration of “hole-mouth” pottery sherds and tabular flint scrapers became a source of circular reasoning to “date” sites and their “duration.” Thus, desert sites became to be perceived as temporary, seasonal, short-lived, while the cultures of desert populations were somehow undervalued. However, radiocarbon dating of desert sites from the Late Neolithic to the Early Bronze Age IV presents a very different scenario. The deserts of the Southern Levant exhibit a full sequence of settlement, a longer life span of individual sites, and a higher level of activity and creativity of the desert people. This paper describes the controversy and presents the 14C data that form the basis for the revised view.The Radiocarbon archives are made available by Radiocarbon and the University of Arizona Libraries. Contact [email protected] for further information.Migrated from OJS platform February 202
    corecore