Experimental investigations of castellated monoblock structures in TEXTOR

Abstract

To insure the thermo-mechanical durability of ITER it is planned to manufacture the castellated armour of the divertor i.e. to split the armour into cells [W. Daener et al., Fusion Eng. Des. 61T62 (2002) 61]. This will cause an increase of the surface area and may lead to carbon deposition and tritium accumulation in the gaps in between cells. To investigate the processes of deposition and fuel accumulation in gaps, a castellated test-limiter was exposed to the SOL plasma of TEXTOR. The geometry of castellation used was the same as proposed for the vertical divertor target in ITER [W. Daener et al., Fusion Eng. Des. 61T62 (2002) 61]. After exposure the limiter was investigated with various surface diagnostic techniques. Deposited layers containing carbon, hydrogen, deuterium and boron were found both on top plasma-facing surfaces and in the gaps. The amount of deuterium in the gaps was at least 30% of that found on the top surfaces. (c) 2004 Elsevier B.V. All rights reserved

Similar works

Full text

thumbnail-image

Juelich Shared Electronic Resources

redirect
Last time updated on 16/05/2016

This paper was published in Juelich Shared Electronic Resources.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.