Rapid determination of 1,2-propylene glycol and glycerol in refill fluids for electronic cigarettes by Raman spectroscopy

Abstract

为实现电子烟烟液主要成分的简便快速检测,建立了同时测定电子烟烟液中1,2-丙二醇和丙三醇含量的拉曼光谱分析方法,利用该方法测定了17个电子烟烟液; 样品,并与气质联用法进行了结果比较。结果表明:①1,2-丙二醇和丙三醇分别在0.125~0.956和0.106~1.120; g/mL时,以522和671 cm~(-1)特征信号峰强度绘制的标准工作曲线线性关系良好(R~2>; 0.999),单样本和独立样本t检验结果证实方法的准确性较高。②17个电子烟烟液样品中,1,2-丙二醇和丙三醇的含量分别为0.533~0.766; 和0.182~0.476; g/mL。该方法与气质联用法检测结果的配对样本t检验结果表明,在95%置信概率下,两种方法的定量结果一致。该方法不需进行样品前处理,更适用于批量; 电子烟烟液中1,2-丙二醇和丙三醇的快速定量分析。A simple and rapid Raman spectroscopy method for simultaneous; determination of 1,2-propylene glycol and glycerol in refill fluids for; electronic cigarettes was developed. Samples of 17 refill fluids were; analyzed by a portable Raman spectrometer,and the data were compared; with those determined by GC-MS. The results showed that: 1) The standard; curves of 1,2-propylene glycol and glycerol determined at the Raman; intensity of 522 and 671 cm~(-1) possessed good correlation coefficients; (R~2 above 0.999) in the content range of 0.125-0.956 and 0.106-1.120; g/mL,respectively. The results of one sample t-test and independent; sample t-test indicated that the Raman method was accurate. 2) The; contents of 1,2-propylene glycol and glycerol in 17 refill fluids were; in the range of 0.533-0.766 and 0.182-0.476 g/mL, respectively. The; result of paired sample t-test showed that the data determined by Raman; spectroscopy were consistent with those obtained by GC-MS at a; confidence level of 95%. Without sample pretreatment, Raman spectroscopy; method is simple to operate and more suitable for the rapid quantitative; determination of 1,2-propylene glycol and glycerol in batches of refill; fluids for electronic cigarettes.浙江中烟工业有限责任公司科技项

    Similar works