This paper presents highly precise measurements of thermal expansion of a
"hybrid" carbon-fiber reinforced silicon carbide composite,
HB-Cesic\textregistered - a trademark of ECM, in the temperature region of
\sim310-10K. Whilst C/SiC composites have been considered to be promising for
the mirrors and other structures of space-borne cryogenic telescopes, the
anisotropic thermal expansion has been a potential disadvantage of this
material. HB-Cesic\textregistered is a newly developed composite using a
mixture of different types of chopped, short carbon-fiber, in which one of the
important aims of the development was to reduce the anisotropy. The
measurements indicate that the anisotropy was much reduced down to 4% as a
result of hybridization. The thermal expansion data obtained are presented as
functions of temperature using eighth-order polynomials separately for the
horizontal (XY-) and vertical (Z-) directions of the fabrication process. The
average CTEs and their dispersion (1{\sigma}) in the range 293-10K derived from
the data for the XY- and Z-directions were 0.805±0.003\times10−6
K−1 and 0.837\pm0.001\times10−6 K−1, respectively. The absolute
accuracy and the reproducibility of the present measurements are suggested to
be better than 0.01\times10−6 K−1 and 0.001\times(10)^{-6} K^{-1},
respectively. The residual anisotropy of the thermal expansion was consistent
with our previous speculation regarding carbon-fiber, in which the residual
anisotropy tended to lie mainly in the horizontal plane.Comment: Accepted by Cryogeincs. 12 pages, 3 figures, 1 tabll