Two-phase choked flow of subcooled oxygen and nitrogen
- Publication date
- Publisher
Abstract
Data are presented for two-phase critical flow through nozzles. Test results from two converging-diverging nozzles and two separate test facilities are in excellent agreement. The critical flow rate and critical flow pressure ratio data conclusively demonstrate that the principle of corresponding states can be applied to two-phase choked flow through nozzles. Normalizing parameters were developed to correlate these data, and current theories can provide an adequate means for extrapolating to other fluids. Such information can be useful for cryogenic fluid storage applications