CORE
🇺🇦
make metadata, not war
Services
Research
Services overview
Explore all CORE services
Access to raw data
API
Dataset
FastSync
Content discovery
Recommender
Discovery
OAI identifiers
OAI Resolver
Managing content
Dashboard
Bespoke contracts
Consultancy services
Support us
Support us
Membership
Sponsorship
Community governance
Advisory Board
Board of supporters
Research network
About
About us
Our mission
Team
Blog
FAQs
Contact us
A smart wearable device for monitoring and self-management of diabetic foot: A proof of concept study
Authors
M. Malek
K. Moulaei
A. Sheikhtaheri
Publication date
1 January 2021
Publisher
Abstract
Background and Objective: Diabetic foot is one of the important complications of diabetes, which is occurred due to the destructive parameters in different anatomical sites of feet. Management and monitoring of these parameters are very important to decrease or prevent foot ulcers. We aimed to develop a smart wearable device to monitor these parameters to prevent diabetic foot. Methods: Following literature review and expert panel discussions, we considered pressure, temperature and humidity to develop the system. During these sessions, we also developed the system architecture and determined the required technologies. We also developed a mobile application. Finally, all sensors were evaluated for accurate monitoring of pressure, temperature and humidity. A standard protocol was used to evaluate each of these sensors. To this end, five people (four with diabetes and one healthy person) participated. They did a series of movements including walking, sitting, and standing. We considered the pressure measured by Pedar system as the gold standard. Furthermore, we changed the environment temperature and humidity during several experiments and considered the environment temperature and humidity as gold standard. We compared the measured values by sensors with these gold standards. Results: The evaluation indicated the accurate performance of pressure, humidity and temperature sensors. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the system to provide alarms based on the pressure measured using Pedar were 100, 50, 92.5, 91.8, and 100 , respectively. The performance of temperature sensors in smart shoes was confirmed by slight differences compared to thermometers. Relatively equal values of humidity measured by two sensors on the left and right feet and the increased difference with the environment humidity showed the exact humidity measured using these sensors. Conclusion: This smart shoes monitors pressure, humidity, and temperature of patients� feet and sends this data to their smart phone by the Bluetooth module. Furthermore, it controls these parameters; as each of these parameters exceeds the defined threshold, alerts are given to patients for self-management. © 2020 Elsevier B.V
Similar works
Full text
Available Versions
eprints Iran University of Medical Sciences
See this paper in CORE
Go to the repository landing page
Download from data provider
oai:eprints.iums.ac.ir:32934
Last time updated on 17/03/2021