324,124 research outputs found

    Comparison of hot wire/laser velocimeter turbulence intensity measurements

    Get PDF
    The question of whether a random measure of particle velocities yields a good statistical estimate of the stationary condition of the turbulence flow field was investigated by comparing hot-wire and laser velocimeter turbulence intensity measurements. Great care was taken to insure that the instrument precision of both the laser velocimeter and hot wire was maximized. In this attempt to reduce the measurement uncertainties in the hot wire, direct digitization of the analog output signal was performed with point-by-point conversion to velocity through a spline fit calibration curve and the turbulence intensity function was calculated statistically. Frequent calibrations of the hot wire were performed using the laser velocimeter as the velocity standard to account for the presence of the small seed particles in the air flow and signal drift in the hot wire

    Characterization of particles in the Langley 0.3 meter transonic cryogenic tunnel using hot wire anemometry

    Get PDF
    Hot wire anemometry was used to identify the nature of particles reportedly observed during free stream velocity measurements in the Langley 0.3-meter transonic cryogenic tunnel using a Laser Doppler Velocimeter. Since the heat-transfer process from the hot wire depends on the thermal conductivity and sticking capability of the particles, it was anticipated that the hot wire anemometer response would be affected differently upon impaction by liquid droplets and solid aerosols in the test gas stream. Based on the measured time response of the hot-wire anemometer in the cryogenic tunnel operated in the 0.3-0.8 Mach number range, it is concluded that the particles impacting the hot wire are liquid in nature rather than solid aerosols. It is further surmised that the liquid aerosols are unevaporated liquid nitrogen droplets used for cooling the tunnel test gas

    Metallic hot wire anemometer

    Get PDF
    A hot wire anemometer is described which has a body formed of heat resistant metal such as an alloy high in nickel content which supports a probe wire disposed in a V groove in the body. The V groove contains a high temperature ceramic adhesive that partially encompasses the downstream side of the probe wire. Mechanical and electrical connection to the probe wire is achieved through conductive support rods that are constructed of the same high temperature metal, insulation between the body and the conductor rods being provided by a coating of an oxide of the same material which coating is formed in situ. The oxide coating insulates the conductor rods from the body, mechanically fixes the conductors within the body, and maintains its integrity at elevated temperatures

    Oscillating hot-wire anemometer

    Get PDF
    Performance analysis was made of oscillating hot-wire anemometer electrical output in gas stream. Advantages include no calibration and measurement of fluid direction as well as fluid speed

    Hot-wire and hot-film anemometry

    Get PDF
    The circuit techniques, electronics, dynamic properties, and the applications of the anemometers are given

    The response of hot wires in high Reynolds-number turbulent pipe flow

    Get PDF
    Issues concerning the accuracy of hot-wire measurements in turbulent pipe flow are addressed for pipe Reynolds numbers up to 6 Γ— 106 and hot-wire Reynolds numbers up to Rew ap 250. These include the optimization of spatial and temporal resolution and the associated feature of signal-to-noise ratio. Very high wire Reynolds numbers enable the use of wires with reduced length-to-diameter ratios compared to those typical of atmospheric conditions owing to increased wire Nusselt numbers. Simulation of the steady-state heat balance for the wire and the unetched portion of wire are used to assess static end-conduction effects: they are used to calculate wire Biot numbers, \sqrt{c_0}l , and fractional end-conduction losses, Οƒ, which confirm the 'conduction-only' theory described by Corrsin. They show that, at Rew ap 250, the wire length-to-diameter ratio can be reduced to about 50, while keeping \sqrt{c_0}l\gt3 and Οƒ < 7% in common with accepted limits at Rew ap 3. It is shown that these limits depend additionally on the choice of wire material and the length of unetched wire. The dynamic effects of end-cooling are also assessed using the conduction-only theory

    Hot wire liquid level detector for cryogenic fluids Patent

    Get PDF
    Hot-wire liquid level detector for cryogenic propellant

    Experimental investigation of flow over a backward facing step-progress report

    Get PDF
    The sizes and arrangement of the wind tunnel used for the experimentation are described. The specifications for the cold-wire anemometers, hot-wire anemometers, cold-wire rakes, and miniature 3-wire probe are proveded. The results of the experiment are briefly discussed

    Amplification of Reynolds number dependent processes by wave distortion

    Get PDF
    A system using a hot-wire transducer as an analog of a liquid droplet of propellant was employed to investigate the ingredients of the acoustic instability of liquid-propellant rocket engines. It was assumed that the combustion process was vaporization-limited and that the combustion chamber was acoustically similar to a closed-closed right-circular cylinder. Before studying the hot-wire closed-loop system (the analog system), a microphone closed-loop system, which used the response of a microphone as the source of a linear feedback exciting signal, was investigated to establish the characteristics of self-sustenance of acoustic fields. Self-sustained acoustic fields were found to occur only at resonant frequencies of the chamber. In the hot-wire closed-loop system, the response of hot-wire anemometer was used as the source of the feedback exciting signal. The self-sustained acoustic fields which developed in the system were always found to be harmonically distorted and to have as their fundamental frquency a resonant frequency for which there also existed a second resonant frequency which was approximately twice the fundamental frequency

    Hot-wire anemometry in hypersonic helium flow

    Get PDF
    Hot-wire anemometry techniques are described that have been developed and used for hypersonic-helium-flow studies. The short run time available dictated certain innovations in applying conventional hot-wire techniques. Some examples are given to show the application of the techniques used. Modifications to conventional equipment are described, including probe modifications and probe heating controls
    • …
    corecore