26 research outputs found

    Antithrombotic therapy in patients undergoing TAVI: An overview of Dutch hospitals

    Get PDF
    Purpose To assess current antithrombotic treatment strategies in the Netherlands in patients undergoing transcatheter aortic valve implantation (TAVI). Methods For every Dutch hospital performing TAVI (n =14) an interventional cardiologist experienced in performing TAVI was interviewed concerning heparin, aspirin, thienopyridine and oral anticoagulation treatment in patients undergoing TAVI. Results The response rate was 100 %. In every centre, a protocol for antithrombotic treatment after TAVI was available. Aspirin was prescribed in all centres, concomitant clopidogrel was prescribed 13 of the 14 centres. Duration of concomitant clopidogrel was 3 months in over twothirds of cases. In 2 centres, duration of concomitant clopidogrel was based upon type of prosthesis: 6 months versus 3 months for supra-annular and intra-annular prostheses, respectively. Conclusions Leaning on a small basis of evidence and recommendations, the antithrombotic policy for patients undergoing TAVI is highly variable in the Netherlands. As a standardised regimen might further reduce haemorrhagic complications, large randomised clinical trials may help to establish the most appropriate approach

    Minimally Invasive Mitral Valve Surgery: A Systematic Review

    Get PDF
    In the recent years minimally invasive mitral valve surgery (MIMVS) has become a well-established and increasingly used option for managing patients with a mitral valve pathology. Nonetheless, whether the purported benefits of MIMVS translate into clinically important outcomes remains controversial. Therefore, in this paper we provide an overview of MIMVS and discuss results, morbidity, mortality, and quality of life following mitral minimally invasive procedures. MIMVS has been proven to be a feasible alternative to the conventional full sternotomy approach with low perioperative morbidity and short-term mortality. Reported benefits of MIMVS include also decreased postoperative pain, improved postoperative respiratory function, reduced surgical trauma, and greater patient satisfaction. Finally, compared to standard surgery, MIMVS demonstrated comparable efficacy across a range of long-term efficacy measures such as freedom from reoperation and long-term survival

    Importance of anterior leaflet tethering in predicting recurrence of ischemic mitral regurgitation after restrictive annuloplasty

    Get PDF
    ObjectiveWe investigated the relationship between anterior mitral leaflet (AML) tethering and recurrent ischemic mitral regurgitation (MR) after restrictive annuloplasty. We also explored whether the effect of AML tethering was secondary to modifications in left ventricular size and geometry.MethodsThe study population consisted of 435 consecutive patients with chronic ischemic MR who survived combined coronary artery bypass grafting and undersized mitral ring annuloplasty performed at 3 institutions (University Hospital, Maastricht, The Netherlands; Careggi Hospital, Florence, Italy; and Civic Hospital, Brescia, Italy) from 2001 to 2008. The median follow-up was 44.7 months (interquartile range 25.9–66.4). The patients were divided by the baseline measurements into quintiles of AML tethering angle α′ as follows: group 1, normal/slight AML tethering; group 2, mild AML tethering; group 3, moderate AML tethering; group 4, moderate-to-severe AML tethering; and group 5, severe AML tethering.ResultsRecurrence of MR was significantly greater in patients with moderate-to-severe (28.3%) and severe (39.4%) AML tethering (P < .001). A strong correlation was found between α′ (r = 0.83, P < .001) and recurrent MR but a weak correlation with the posterior mitral angle β′ (r = 0.12, P = .05). On logistic regression analysis corrected for other echocardiographic risk factors, moderate-severe AML tethering or worse (adjusted odds ratio, 3.6; 95% confidence interval, 3.0–4.1; P < .001) was a strong predictor of MR recurrence. Compared with patients with β′ of 45 or greater, those with severe and moderate-severe AML tethering had more than 3.7 and 1.7 times greater odds of MR recurrence, respectively. No significant interactions were found between α′ and the indexes of left ventricular function and geometry.ConclusionsPreoperative moderate-severe AML tethering or worse was strongly associated with MR recurrence. Thus, assessment of leaflet tethering should be incorporated into clinical risk assessment and prediction models

    Transcatheter Aortic Valve Implantation-Induced Left Bundle Branch Block: Causes and Consequences

    No full text
    Transcatheter aortic valve implantation (TAVI) is an alternative treatment option for patients with severe aortic valve stenosis who do not qualify for surgical aortic valve replacement (AVR). Besides its proven clinical benefits, one of the complications of TAVI is the creation of conduction abnormalities, like left bundle branch block (LBBB). New LBBB occurs between 7 and 65 % of cases, numbers that differ considerably between devices. In this review, we discuss the possible causes and the clinical significance of TAVI-induced LBBB. Several device- and procedural-related factors seem responsible for the development of LBBB, of which depth of implantation and balloon-annulus diameter ratio are the most important ones. TAVI-induced LBBB negatively affects cardiac function and hospitalization, but its impact on mortality is subject of debate. Future research and registries should implement strict diagnostic criteria for LBBB together with recording of its timing and persistence
    corecore