46 research outputs found
Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
A highly stable monitoring system based on blue and red light emitting diodes
coupled to a distribution network comprised of optical fibers has been
developed for an electromagnetic calorimeter that uses lead tungstate crystals
readout with photomultiplier tubes. We report of the system prototype design
and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has
been achieved during one week of prototype operation.Comment: 10 pages, 6 figures, LaTeX2
Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
Radiation damage in lead tungstate crystals reduces their transparency. The
calibration that relates the amount of light detected in such crystals to
incident energy of photons or electrons is of paramount importance to
maintaining the energy resolution the detection system. We report on tests of
lead tungstate crystals, read out by photomultiplier tubes, exposed to
irradiation by monoenergetic electron or pion beams. The beam electrons
themselves were used to measure the scintillation light output, and a blue
light emitting diode (LED) was used to track variations of crystals
transparency. We report on the correlation of the LED measurement with
radiation damage by the beams and also show that it can accurately monitor the
crystals recovery from such damage.Comment: 9 pages, 6 figures, LaTeX2
LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype
We report on the performance of a monitoring system for a prototype
calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled
with photomultiplier tubes. The tests were carried out at the 70 GeV
accelerator complex at Protvino, Russia.Comment: 12 pages, 8 figures, LaTeX2e, revised versio
First study of radiation hardness of lead tungstate crystals at low temperatures
The electromagnetic calorimeter of PANDA at the FAIR facility will rely on an
operation of lead tungstate (PWO) scintillation crystals at temperatures near
-25 deg.C to provide sufficient resolution for photons in the energy range from
8 GeV down to 10 MeV. Radiation hardness of PWO crystals was studied at the
IHEP (Protvino) irradiation facility in the temperature range from room
temperature down to -25 deg.C. These studies have indicated a significantly
different behaviour in the time evolution of the damaging processes well below
room temperature. Different signal loss levels at the same dose rate, but at
different temperatures were observed. The effect of a deep suppression of the
crystal recovery process at temperatures below
0 deg.C has been seen.Comment: 10 pages 7 figure
Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation
Studies of the radiation hardness of lead tungstate crystals produced by the
Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of
Ceramics in China have been carried out at IHEP, Protvino. The crystals were
irradiated by a 40-GeV pion beam. After full recovery, the same crystals were
irradiated using a -ray source. The dose rate profiles along
the crystal length were observed to be quite similar. We compare the effects of
the two types of radiation on the crystals light output.Comment: 10 pages, 8 figures, Latex 2e, 28.04.04 - minor grammatical change
Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams
We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino
Precision Measurement of Energy and Position Resolutions of the BTeV Electromagnetic Calorimeter Prototype
The energy dependence of the energy and position resolutions of the electromagnetic calorimeter prototype made of lead tungstate crystals produced in Bogoroditsk (Russia) and Shanghai (China) is presented. These measurementswere carried out at the Protvino accelerator using a 1 to 45 GeV electron beam. The crystals were coupled to photomultiplier tubes. The dependence of energy and position resolutions on different factors as well as the measured electromagnetic shower lateral profile are presented
Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams
We report on the effects of radiation on the light output of lead tungstate
crystals. The crystals were irradiated by pure, intense high energy electron
and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The
crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai
(China). These studies were carried out at the 70-GeV proton accelerator in
Protvino
Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV
The fine-sampling electromagnetic calorimeter prototype has been
experimentally tested using the 1-19 GeV/c tagged beams of negatively charged
particles at the U70 accelerator at IHEP, Protvino. The energy resolution
measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position
resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the
cell. The lateral non-uniformity of the prototype energy response to electrons
and MIPs has turned out to be negligible. Obtained experimental results are in
a good agreement with Monte-Carlo simulations.Comment: Article is prepared for pdflatex using the class elsart. 13 pages, 9
figures in 11 PDF file
Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range
A beam line for electrons with energies in the range of 1 to 45 GeV, low
contamination of hadrons and muons and high intensity up to 10^6 per
accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A
beam tagging system based on drift chambers with 160 micron resolution was able
to measure relative electron beam momentum precisely. The resolution sigma_p p
was 0.13% at 45 GeV where multiple scattering is negligible. This test beam
setup provided the possibility to study properties of lead tungstate crystals
(PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic
Calorimeter grou