27 research outputs found

    Isolated tau leptons in events with large missing transverse momentum at HERA

    Get PDF
    A search for events containing isolated tau leptons and large missing transverse momentum, not originating from the tau decay, has been performed with the ZEUS detector at the electron-proton collider HERA, using 130 pb^-1 of integrated luminosity. A search was made for isolated tracks coming from hadronic tau decays. Observables based on the internal jet structure were exploited to discriminate between tau decays and quark- or gluon-induced jets. Three tau candidates were found, while 0.40 +0.12 -0.13 were expected from Standard Model processes, such as charged current deep inelastic scattering and single W-boson production. To search for heavy-particle decays, a more restrictive selection was applied to isolate tau leptons produced together with a hadronic final state with high transverse momentum. Two candidate events survive, while 0.20 +-0.05 events are expected from Standard Model processes.Comment: 28 pages, 4 figures, 3 tables, accepted by Phys. Lett. B. Updated with minor changes to the text requested by the journal refere

    Математичне моделювання фізичних процесів перетворення електромагнітного поля в поле пружних коливань в мікротовщинних шарах металів

    No full text
    The results of the mathematical studies on the modeling of high-frequency electromagnetic field conversion in the field of elastic oscillations process in microthick surface layers or electrically conductive ferromagnetic material thin films placed in a magnetic field are given, taking into account the coherence of elastic, electric and magnetic properties of the metal. It is shown that in practical calculations, especially in the case of high-frequency oscillations, it is necessary to take into account thickness of skin layer in which electromagnetic field transforms into acoustic field.Приведены результаты математических исследований по моделированию процесса преобразования высокочастотного электромагнитного поля в поле упругих колебаний в микротолщинных поверхностных слоях или тонких пленках из электропроводного ферромагнитного материала, помещенного в магнитное поле, с учетом связности упругих, электрических и магнитных свойств металла. Показано, что при практических расчѐтах, особенно в случае высокочастотных колебаний, необходимо учитывать толщину скин-слоя, в котором происходит преобразование электромагнитного поля в акустическое.Наведено результати математичних досліджень з моделювання процесу перетворення високочас- тотного електромагнітного поля в поле пружних коливань в мікротовщинних поверхневих шарах або тонких плівках з електропровідного феромагнітного матеріалу, розміщеного в магнітному полі, з ура- хуванням зв'язності пружних, електричних і магнітних властивостей металу. Показано, що при прак- тичних розрахунках, особливо в разі високочастотних коливань, необхідно враховувати товщину скін- шару, в якому відбувається перетворення електромагнітного поля в акустичне

    Фізичні основи створення безконтактних ультразвукових частотних сенсорів для дослідження нанокристалічних феромагнітних матеріалів

    No full text
    A mathematical model is developed to determine the force impacts that are formed when the electromagnetic field is transformed into a field of ultrasonic oscillations in the skin layer of an electrically conductive ferromagnetic material of an anisotropic magnetic permeability. The main factors determining the excited acoustic field with allowance for permissible limitations are established. It is shown that the main contribution to the acoustic vibrations energetics is made by the magnetostrictive component of the skin layer material, in which the high-frequency electromagnetic field is transformed into an acoustic field.Разработана математическая модель по определению силовых воздействий, формируемых при преобразовании электромагнитного поля в поле ультразвуковых колебаний в скин-слое электропроводного ферромагнитного материала анизотропного по магнитной проницаемости. Установлены основные факторы, определяющие возбуждаемое акустическое поле с учетом допустимых ограничений. Показано, что основной вклад в энергетику акустических колебаний вносит магнитострикционная составляющая материала скин-слоя, в котором происходит преобразование высокочастотного электромагнитного поля в акустическое.Розроблено математичну модель по визначенню силових впливів, які формуються при перетворенні електромагнітного поля в поле ультразвукових коливань в скін-шарі електропровідного феромагнітного матеріалу анізотропного по магнітній проникності. Встановлено основні фактори, що визначають збуджене акустичне поле з урахуванням допустимих обмежень. Показано, що основний внесок в енергетику акустичних коливань вносить магнітострикційна складова матеріалу скін-шару, в якому відбувається перетворення високочастотного електромагнітного поля в акустичне

    The ATLAS Transition Radiation Tracker (TRT) proportional drift tube: design and performance

    No full text
    A straw proportional counter is the basic element of the ATLAS Transition Radiation Tracker (TRT). Its detailed properties as well as the main properties of a few TRT operating gas mixtures are described. Particular attention is paid to straw tube performance in high radiation conditions and to its operational stability

    The ATLAS TRT electronics

    No full text
    The ATLAS inner detector consists of three sub-systems: the pixel detector spanning the radius range 4cm-20cm, the semiconductor tracker at radii from 30 to 52 cm, and the transition radiation tracker (TRT), tracking from 56 to 107 cm. The TRT provides a combination of continuous tracking with many projective measurements based on individual drift tubes (or straws) and of electron identification based on transition radiation from fibres or foils interleaved between the straws themselves. This paper describes the on and off detector electronics for the TRT as well as the TRT portion of the data acquisition (DAQ) system

    The ATLAS TRT end-cap detectors

    No full text
    The ATLAS TRT end-cap is a tracking drift chamber using 245,760 individual tubular drift tubes. It is a part of the TRT tracker which consist of the barrel and two end-caps. The TRT end-caps cover the forward and backward pseudo-rapidity region 1.0 < |h| < 2.0, while the TRT barrel central h region |h| < 1.0. The TRT system provides a combination of continuous tracking with many measurements in individual drift tubes (or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. Along with other two sub-systems, namely the Pixel detector and Semi Conductor Tracker (SCT), the TRT constitutes the ATLAS Inner Detector. This paper describes the recently completed and installed TRT end-cap detectors, their design, assembly, integration and the acceptance tests applied during the construction
    corecore