1,756 research outputs found

    The management of segmental tibial shaft fractures: A systematic review.

    Get PDF
    INTRODUCTION: Segmental tibial fractures are complex injuries associated with significant soft tissue damage that are difficult to treat. This study aimed to identify the most effective method of treating segmental tibial fractures. METHOD: A PRISMA compliant systematic review was conducted. Studies investigating the management of segmental tibial fractures with intramedullary nail fixation (IMN), open reduction and internal fixation (ORIF) or circular external fixation (CEF) were included for review. The primary outcome measure was time to fracture union. Secondary outcomes were complications and functional outcome. A narrative analysis was undertaken as meta-analysis was inappropriate due to heterogeneity of the data. RESULTS: Thirteen studies were eligible and included. No randomised controlled trials were identified. Fixation with an intramedullary nail provided the fastest time to union, followed by open reduction and internal fixation and then CEF. The rate of deep infection was highest after IMN (5/162 [3%]), followed by open reduction and internal fixation (2/78 [2.5%]) and CEF (1/54 [2%]). However, some studies reported particularly high rates of infection following IMN for open segmental tibial fractures. There was limited reporting of postoperative deformities. From the studies that did include such data, there was a higher rate of deformity following ORIF (8/53 [15%]), compared to IMN (13/138 [9%]), and CEF (4/44 [9%]). Three studies, not including IMN, described patient reported outcome measures with results ranging from 'excellent' to 'fair'. DISCUSSION: The available evidence was of poor quality, dominated by retrospective case series. This prevented statistical analysis, and precludes firm conclusions being drawn from the results available. CONCLUSION: IMN has the fastest time to fracture union, however there are concerns regarding an increased deep infection rate in open segmental tibial fractures. In this subgroup, the data suggests CEF provides the most satisfactory results. However, the available literature does not provide sufficient detail to make this statement with certainty. We recommend a randomised controlled study to further investigate this challenging problem

    Treatment compliance and effectiveness of a cognitive behavioural intervention for low back pain : a complier average causal effect approach to the BeST data set

    Get PDF
    Background: Group cognitive behavioural intervention (CBI) is effective in reducing low-back pain and disability in comparison to advice in primary care. The aim of this analysis was to investigate the impact of compliance on estimates of treatment effect and to identify factors associated with compliance. Methods: In this multicentre trial, 701 adults with troublesome sub-acute or chronic low-back pain were recruited from 56 general practices. Participants were randomised to advice (control n = 233) or advice plus CBI (n = 468). Compliance was specified a priori as attending a minimum of three group sessions and the individual assessment. We estimated the complier average causal effect (CACE) of treatment. Results: Comparison of the CACE estimate of the mean treatment difference to the intention-to-treat (ITT) estimate at 12 months showed a greater benefit of CBI amongst participants compliant with treatment on the Roland Morris Questionnaire (CACE: 1.6 points, 95% CI 0.51 to 2.74; ITT: 1.3 points, 95% CI 0.55 to 2.07), the Modified Von Korff disability score (CACE: 12.1 points, 95% CI 6.07 to 18.17; ITT: 8.6 points, 95% CI 4.58 to 12.64) and the Modified von Korff pain score (CACE: 10.4 points, 95% CI 4.64 to 16.10; ITT: 7.0 points, 95% CI 3.26 to 10.74). People who were non-compliant were younger and had higher pain scores at randomisation. Conclusions: Treatment compliance is important in the effectiveness of group CBI. Younger people and those with more pain are at greater risk of non-compliance

    Osteocytes and mechanical loading: The Wnt connection

    Get PDF
    Bone adapts to the mechanical forces that it experiences. Orthodontic tooth movement harnesses the cell‐ and tissue‐level properties of mechanotransduction to achieve alignment and reorganization of the dentition. However, the mechanisms of action that permit bone resorption and formation in response to loads placed on the teeth are incompletely elucidated, though several mechanisms have been identified. Wnt/Lrp5 signalling in osteocytes is a key pathway that modulates bone tissue's response to load. Numerous mouse models that harbour knock‐in, knockout and transgenic/overexpression alleles targeting genes related to Wnt signalling point to the necessity of Wnt/Lrp5, and its localization to osteocytes, for proper mechanotransduction in bone. Alveolar bone is rich in osteocytes and is a highly mechanoresponsive tissue in which components of the canonical Wnt signalling cascade have been identified. As Wnt‐based agents become clinically available in the next several years, the major challenge that lies ahead will be to gain a more complete understanding of Wnt biology in alveolar bone so that improved/expedited tooth movement becomes a possibility

    The treatment of segmental tibial fractures: does patient preference differ from surgeon choice?

    Get PDF
    INTRODUCTION: Segmental tibial fractures are complex injuries with a prolonged recovery time. Current definitive treatment options include intramedullary fixation or a circular external fixator. However, there is uncertainty as to which surgical option is preferable and there are no sufficiently rigorous multi-centre trials that have answered this question. The objective of this study was to determine whether patient and surgeon opinion was permissive for a randomised controlled trial (RCT) comparing intramedullary nailing to the application of a circular external fixator. MATERIALS AND METHODS: A convenience questionnaire survey of attending surgeons was conducted during the United Kingdom's Orthopaedic Trauma Society annual meeting 2017 to determine the treatment modalities used for a segmental tibial fracture (n=63). Patient opinion was obtained from clinical patients who had been treated for a segmental tibial fracture as part of a patient and public involvement focus group with questions covering the domains of surgical preference, treatment expectations, outcome, the consent process and follow-up regime (n=5). RESULTS: Based on the surgeon survey, 39% routinely use circular frame fixation following segmental tibial fracture compared to 61% who use nail fixation. Nail fixation was reported as the treatment of choice for a closed injury in a healthy patient in 81% of surgeons, and by 86% for a patient with a closed fracture who was obese. Twenty-one percent reported that they would use a nail for an open segmental tibia fracture in diabetics who smoked, whilst 57% would opt for a nail for a closed injury with compartment syndrome, and only 27% would use a nail for an open segmental injury in a young fit sports person. The patient and public preference exercise identified that sleep, early functional outcomes and psychosocial measures of outcomes are important. CONCLUSION: We concluded that a RCT comparing definitive fixation with an intramedullary nail and a circular external fixator is justified as there remains uncertainty on the optimal surgical management for segmental tibial fractures. Furthermore, psychosocial factors and early post-operative outcomes should be reported as core outcome measures as part of such a trial

    Estimating the incidence of acute infectious intestinal disease in the community in the UK:A retrospective telephone survey

    Get PDF
    Objectives: To estimate the burden of intestinal infectious disease (IID) in the UK and determine whether disease burden estimations using a retrospective study design differ from those using a prospective study design. Design/Setting: A retrospective telephone survey undertaken in each of the four countries comprising the United Kingdom. Participants were randomly asked about illness either in the past 7 or 28 days. Participants: 14,813 individuals for all of whom we had a legible recording of their agreement to participate Outcomes: Self-reported IID, defined as loose stools or clinically significant vomiting lasting less than two weeks, in the absence of a known non-infectious cause. Results: The rate of self-reported IID varied substantially depending on whether asked for illness in the previous 7 or 28 days. After standardising for age and sex, and adjusting for the number of interviews completed each month and the relative size of each UK country, the estimated rate of IID in the 7-day recall group was 1,530 cases per 1,000 person-years (95% CI: 1135 – 2113), while in the 28-day recall group it was 533 cases per 1,000 person-years (95% CI: 377 – 778). There was no significant variation in rates between the four countries. Rates in this study were also higher than in a related prospective study undertaken at the same time. Conclusions: The estimated burden of disease from IID varied dramatically depending on study design. Retrospective studies of IID give higher estimates of disease burden than prospective studies. Of retrospective studies longer recall periods give lower estimated rates than studies with short recall periods. Caution needs to be exercised when comparing studies of self-reported IID as small changes in study design or case definition can markedly affect estimated rates

    Application of the speed-duration relationship to normalize the intensity of high-intensity interval training

    Get PDF
    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (P<0.050). For maximal HIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229±27 s; Bout 2: 262±37 s; Bout 3: 235±49 s; Bout 4: 235±53 s; P>0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m), 3 (136.9±38.9 m), and 4 (136.7±39.3 m), compared with bout 1 (264.9±58.7 m; P>0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols

    Different proteolipid protein mutants exhibit unique metabolic defects

    Get PDF
    PMD (Pelizaeus–Merzbacher disease), a CNS (central nervous system) disease characterized by shortened lifespan and severe neural dysfunction, is caused by mutations of the PLP1 (X-linked myelin proteolipid protein) gene. The majority of human PLP1 mutations are caused by duplications; almost all others are caused by missense mutations. The cellular events leading to the phenotype are unknown. The same mutations in non-humans make them ideal models to study the mechanisms that cause neurological sequelae. In the present study we show that mice with Plp1 duplications (Plp1tg) have major mitochondrial deficits with a 50% reduction in ATP, a drastically reduced mitochondrial membrane potential and increased numbers of mitochondria. In contrast, the jp (jimpy) mouse with a Plp1 missense mutation exhibits normal mitochondrial function. We show that PLP in the Plp1tg mice and in Plp1-transfected cells is targeted to mitochondria. PLP has motifs permissive for insertion into mitochondria and deletions near its N-terminus prevent its co-localization to mitochondria. These novel data show that Plp1 missense mutations and duplications of the native Plp1 gene initiate uniquely different cellular responses

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components
    corecore