35 research outputs found

    Pain Perception and Rate of Canine Retraction Through Self- Ligating Brackets and Conventional Elastomeric Ligation System: A Split Mouth Study

    Get PDF
    Objective: To evaluate the rate of tooth movement and the pain perception via self-ligating (SL) and conventional elastomeric ligation brackets (CB) system. Material and Methods: This study has been conducted at the Orthodontic Department of Baqai Dental College, Baqai Medical University. The sample size of this study comprised 40 patients, falling between the age of 12-30 years without any sex discrimination. Shapiro-Wilk was used to check the distribution of data. Non-parametric Mann Whitney U test was applied to evaluate the pain associated with SL and CB brackets system. To analysis the canine retraction Wilcoxon test was applied for the comparison of CB and SL brackets system. For all statistical analyses, the p-value of <0.05 was considered significant. Results: Pain level associated with retraction via CB and SL shows significant differences. However, the rate of canine retraction via CB and SL shows no significant differences at stages T0-T1 and T1-T2. However, stage T2-T3 shows a significant difference. Conclusion: As pain during orthodontic treatment is mostly associated with the level of compression of the periodontal ligament, it may be hypothesized that lower frictional forces generate less compression of the periodontal ligament and blood vessels, and so alter the type of pain experienced

    Shortening of atrioventricular delay at increased atrial paced heart rates improves diastolic filling and functional class in patients with biventricular pacing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Use of rate adaptive atrioventricular (AV) delay remains controversial in patients with biventricular (Biv) pacing. We hypothesized that a shortened AV delay would provide optimal diastolic filling by allowing separation of early and late diastolic filling at increased heart rate (HR) in these patients.</p> <p>Methods</p> <p>34 patients (75 ± 11 yrs, 24 M, LVEF 34 ± 12%) with Biv and atrial pacing had optimal AV delay determined at baseline HR by Doppler echocardiography. Atrial pacing rate was then increased in 10 bpm increments to a maximum of 90 bpm. At each atrial pacing HR, optimal AV delay was determined by changing AV delay until best E and A wave separation was seen on mitral inflow pulsed wave (PW) Doppler (defined as increased atrial duration from baseline or prior pacemaker setting with minimal atrial truncation). Left ventricular (LV) systolic ejection time and velocity time integral (VTI) at fixed and optimal AV delay was also tested in 13 patients. Rate adaptive AV delay was then programmed according to the optimal AV delay at the highest HR tested and patients were followed for 1 month to assess change in NYHA class and Quality of Life Score as assessed by Minnesota Living with Heart Failure Questionnaire.</p> <p>Results</p> <p>81 AV delays were evaluated at different atrial pacing rates. Optimal AV delay decreased as atrial paced HR increased (201 ms at 60 bpm, 187 ms at 70 bpm, 146 ms at 80 bpm and 123 ms at 90 bpm (ANOVA F-statistic = 15, p = 0.0010). Diastolic filling time (P < 0.001 vs. fixed AV delay), mitral inflow VTI (p < 0.05 vs fixed AV delay) and systolic ejection time (p < 0.02 vs. fixed AV delay) improved by 14%, 5% and 4% respectively at optimal versus fixed AV delay at the same HR. NYHA improved from 2.6 ± 0.7 at baseline to 1.7 ± 0.8 (p < 0.01) 1 month post optimization. Physical component of Quality of Life Score improved from 32 ± 17 at baseline to 25 ± 12 (p < 0.05) at follow up.</p> <p>Conclusions</p> <p>Increased heart rate by atrial pacing in patients with Biv pacing causes compromise in diastolic filling time which can be improved by AV delay shortening. Aggressive AV delay shortening was required at heart rates in physiologic range to achieve optimal diastolic filling and was associated with an increase in LV ejection time during optimization. Functional class improved at 1 month post optimization using aggressive AV delay shortening algorithm derived from echo-guidance at the time of Biv pacemaker optimization.</p

    CMV quantitative PCR in the diagnosis of CMV disease in patients with HIV-infection – a retrospective autopsy based study

    Get PDF
    Background Patients with advanced HIV infection at the time of diagnosis and patients not responding to antiretroviral therapy are at risk of cytomegalovirus (CMV) disease. Earlier studies of patients with HIV infection have demonstrated that the diagnosis is often first made post-mortem. In recent years new molecular biological tests have become available for diagnosis of CMV disease. Although clinical evaluation of tests for diagnosis of CMV disease in HIV-infected individuals is suboptimal without autopsy, no results from such studies have been published. The aim of this study was to explore the diagnostic utility of CMV quantitative polymerase chain reaction (PCR) in plasma from HIV and CMV seropositive patients who died during the period 1991–2002 and in whom autopsy was performed. Methods Autopsy was performed in all cases, as part of routine evaluation of HIV-infected cases followed at Ullevaal University Hospital. Of 125 patients included, 53 had CMV disease, 37 of whom were first diagnosed at autopsy. CMV disease was diagnosed either by ophthalmoscopic findings typical of CMV retinitis, biopsy or autopsy. One or two plasma samples taken prior to the first diagnosis of CMV disease (alive or at autopsy) or death without CMV disease were analysed by CMV quantitative PCR. Sensitivity, specificity, positive and negative predictive values were calculated for different CMV viral load cut-offs and according to detection of viraemia in one versus two samples. Results Twenty-seven of 53 patients with CMV disease (51%) and 10 of 72 patients without CMV disease (14%) had detectable viraemia in at least one sample. Sensitivity and negative predictive value (NPV) of the test, maximised with a cut-off at the test's limit of detection of CMV viraemia (400 copies/mL), were 47% and 70%, respectively. With cut-off at 10 000 copies/mL, specificity and positive predictive value (PPV) were 100%. With a requirement for CMV viraemia in two samples, specificity and PPV were 100% in patients with CMV viraemia above the limit of detection. Conclusion Our results indicate that quantitative CMV PCR is best used to rule in, rather than to rule out CMV disease in HIV-infected individuals at high risk

    Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Biventricular (Biv) pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP) assessment by radial artery tonometry in guiding Biv pacemaker optimization.</p> <p>Methods</p> <p>Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV) ejection fraction (EF) 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI), ejection time (ET), myocardial performance index (MPI), radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated.</p> <p>Results</p> <p>Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p < 0.001), LV VTI (15.9 ± 4.8 cm to 18.4 ± 5.1 cm, p < 0.001) and MPI (0.57 ± 0.2 to 0.45 ± 0.13, p < 0.001) and in PEP (246.7 ± 36.1 ms to 234.7 ± 35.5 ms, p = 0.003), PEP/ET (0.88 ± 0.21 to 0.79 ± 0.17, p < 0.001), and PEP/VTI (17.3 ± 7 to 13.78 ± 4.7, p < 0.001). The correlation between comprehensive echo Doppler and radial artery tonometry-PEP guided optimal atrioventricular delay (AVD) and optimal interventricular delay (VVD) was 0.75 (p < 0.001) and 0.69 (p < 0.001) respectively. In 29 patients with follow up assessment, New York Heart Association (NYHA) class reduced from 2.5 ± 0.8 to 2.0 ± 0.9 (p = 0.004) at 1.8 ± 1.4 months.</p> <p>Conclusion</p> <p>An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.</p

    Post-traumatic Osteomyelitis due to Aeromonas Species

    No full text
    We report a case of Aeromonas osteomyelitis due to injury in a sewage worker. He presented with cellulitis of the left foot. Radiographs showed evidence of osteomyelitis involving the head and neck of the fifth metatarsal. Aeromonas species was isolated from the tissue and swab from the foot. The head and neck of the fifth metatarsal were excised and the patient improved on 4 weeks of intravenous meropenem followed by 4 weeks of oral clindamycin and ciprofloxacin

    Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

    Get PDF
    Background There are limited reports outlining the financial cost of treating cardiac implantable electronic device (CIED) infection outside the United States. This study aimed to determine the average treatment cost of CIED infection in a large UK tertiary referral centre and compared costs of different treatment pathways that are recognised in the management of CIED infection (early versus delayed re-implantation). Methods We retrospectively analysed cost and length of stay (LOS) data for consecutive patients undergoing infected CIED extraction with cardiac resynchronization therapy (CRT-D [with defibrillator], CRT-P [with pacemaker]), implantable cardioverter-defibrillators (ICDs) and permanent pacemakers (PPMs). Results Between January 2013 and March 2015, complete data was available for 84 patients (18 [21.4%] CRT-D, 24 [28.6%] ICDs and 42 [50.0%] PPMs). When all cases were considered the cost of infection ranged from £5,139 (PPM) to £24,318 (CRT-D). Considering different treatment strategies; 41 (48.8%) underwent CIED extraction and re-implantation during the same admission (early re-implant strategy (ER). 43 (51.2%) underwent extraction, but were then discharged home to be re-admitted for day-case re-implantation (delayed re-implant strategy (DR)). Median LOS was significantly shorter in DR compared to ER (5.0 vs. 18.0 days, p<0.001). The total cost of CIED infection episode was similar for both treatment strategies (median £14,241.48 vs. £14,741.70 including wearable defibrillator (Lifevest) and outpatient antibiotics costs, ER vs. DR; p = 0.491). Conclusion CIED infections are expensive and associated with significant health-economic burden. When all device types were considered, a DR strategy is associated with reduced LOS without an increased cost penalty
    corecore