353 research outputs found

    A Thermodynamic Study of Electroneutral K-Cl Cotransport in pH- and Volume-Clamped Low K Sheep Erythrocytes with Normal and Low Internal Magnesium

    Get PDF
    Swelling-Induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing, This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K-Cl cotransport. The anion exchange inhibitor 4,4\u27diisothiocyanato-2,2\u27disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3 at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal Ii concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl

    A thermodynamic study of electroneutral K-Cl cotransport in pH- and volume-clamped low K sheep erythrocytes with normal and low internal magnesium.

    Get PDF
    Swelling-Induced human erythrocyte K-Cl cotransport is membrane potential independent and capable of uphill transport. However, a complete thermodynamic analysis of basal and stimulated K-Cl cotransport, at constant cell volume, is missing, This study was performed in low K sheep red blood cells before and after reducing cellular free Mg into the nanomolar range with the divalent cation ionophore A23187 and a chelator, an intervention known to stimulate K-Cl cotransport. The anion exchange inhibitor 4,4\u27diisothiocyanato-2,2\u27disulfonic stilbene was used to clamp intracellular pH and Cl or NO3 concentrations. Cell volume was maintained constant as external and internal pH differed by more than two units. K-Cl cotransport was calculated from the K effluxes and Rb (as K congener) influxes measured in Cl and NO3 at constant internal K and external anions, and variable concentrations of extracellular Rb and internal anions, respectively. The external Rb concentration at which net K-Cl cotransport is zero was defined as flux reversal point which changed with internal pH and hence Cl. Plots of the ratio of external Rb concentrations corresponding to the flux reversal points and the internal Ii concentration versus the ratio of the internal and external Cl concentrations (i.e., the Donnan ratio of the transported ions) yielded slopes near unity for both control and low internal Mg cells. Thus, basal as well as low internal Mg-stimulated net K-Cl cotransport depends on the electrochemical potential gradient of KCl

    Mechanisms of hyposmotic volume regulation in isolated nematocytes of the anthozoan Aiptasia diaphana.

    Get PDF
    The nature and role of potassium (K) and water transport mediating hyposmotically-induced regulatory volume decrease (RVD) were studied in nematocytes dissociated with 605 mM thiocyanate from aconti

    Evidence for aquaporin-mediated water transport in nematocytes of the jellyfish Pelagia noctiluca.

    Get PDF
    Nematocytes, the stinging cells of Cnidarians, have a cytoplasm confined to a thin rim. The main cell body is occupied by an organoid, the nematocyst, containing the stinging tubule and venom. Exposed to hypotonic shock, nematocytes initially swell during an osmotic phase (OP) and then undergo regulatory volume decrease (RVD) driven by K+, Cl- and obligatory water extrusion mechanisms. The purpose of this report is to characterize the OP. Nematocytes were isolated by the NaSCN/Ca2+ method from tentacles of the jellyfish Pelagia noctiluca, collected in the Strait of Messina, Italy. Isolated nematocytes were subjected to hyposmotic shock in 65% artificial seawater (ASW) for 15 min. The selective aquaporin water channel inhibitor HgCl2 (0.1-25 µM) applied prior to osmotic shock prevented the OP and thus RVD. These effects were attenuated in the presence of 1mM dithiothreitol (DTT), a mercaptide bond reducing agent. AgNO3 (1 µM) and TEA (tetraethylammonium, 100 µM), also reported to inhibit water transport, did not alter the OP but significantly diminished RVD, suggesting different modes of action for the inhibitors tested. Based on estimates of the nematocyte surface area and volume, and OP duration, a relative water permeability of ∼10-7 cm/sec was calculated and the number of putative aquaporin molecules mediating the OP was estimated. This water permeability is 3-4 orders of magnitude lower in comparison to higher order animals and may constitute an evolutionary advantage for Cnidarian survival

    Coherent Frequency Reference System for the NASA Deep Space Network

    Get PDF
    The NASA Deep Space Network (DSN) requires state-of-the-art frequency references that are derived and distributed from very stable atomic frequency standards. A new Frequency Reference System (FRS) and Frequency Reference Distribution System (FRD) have been developed, which together replace the previous Coherent Reference Generator System (CRG). The FRS and FRD each provide new capabilities that significantly improve operability and reliability. The FRS allows for selection and switching between frequency standards, a flywheel capability (to avoid interruptions when switching frequency standards), and a frequency synthesis system (to generate standardized 5-, 10-, and 100-MHz reference signals). The FRS is powered by redundant, specially filtered, and sustainable power systems and includes a monitor and control capability for station operations to interact and control the frequency-standard selection process. The FRD receives the standardized 5-, 10-, and 100-MHz reference signals and distributes signals to distribution amplifiers in a fan out fashion to dozens of DSN users that require the highly stable reference signals. The FRD is also powered by redundant, specially filtered, and sustainable power systems. The new DSN Frequency Distribution System, which consists of the FRS and FRD systems described here, is central to all operational activities of the NASA DSN. The frequency generation and distribution system provides ultra-stable, coherent, and very low phase-noise references at 5, l0, and 100 MHz to between 60 and 100 separate users at each Deep Space Communications Complex

    Bridging fluorescence microscopy and electron microscopy

    Get PDF
    Development of new fluorescent probes and fluorescence microscopes has led to new ways to study cell biology. With the emergence of specialized microscopy units at most universities and research centers, the use of these techniques is well within reach for a broad research community. A major breakthrough in fluorescence microscopy in biology is the ability to follow specific targets on or in living cells, revealing dynamic localization and/or function of target molecules. One of the inherent limitations of fluorescence microscopy is the resolution. Several efforts are undertaken to overcome this limit. The traditional and most well-known way to achieve higher resolution imaging is by electron microscopy. Moreover, electron microscopy reveals organelles, membranes, macromolecules, and thus aids in the understanding of cellular complexity and localization of molecules of interest in relation to other structures. With the new probe development, a solid bridge between fluorescence microscopy and electron microscopy is being built, even leading to correlative imaging. This connection provides several benefits, both scientifically as well as practically. Here, I summarize recent developments in bridging microscopy
    • …
    corecore