18 research outputs found

    Horse immunization with short-chain consensus α-neurotoxin generates antibodies against broad spectrum of elapid venomous species

    Get PDF
    Antivenoms are fundamental in the therapy for snakebites. In elapid venoms, there are toxins, e.g. short-chain α-neurotoxins, which are quite abundant, highly toxic, and consequently play a major role in envenomation processes. The core problem is that such α-neurotoxins are weakly immunogenic, and many current elapid antivenoms show low reactivity towards them. We have previously developed a recombinant consensus short-chain α-neurotoxin (ScNtx) based on sequences from the most lethal elapid venoms from America, Africa, Asia, and Oceania. Here we report that an antivenom generated by immunizing horses with ScNtx can successfully neutralize the lethality of pure recombinant and native short-chain α-neurotoxins, as well as whole neurotoxic elapid venoms from diverse genera such as Micrurus, Dendroaspis, Naja, Walterinnesia, Ophiophagus and Hydrophis. These results provide a proof-ofprinciple for using recombinant proteins with rationally designed consensus sequences as universal immunogens for developing next-generation antivenoms with higher effectiveness and broader neutralizing capacity.Universidad de Costa Rica/[741-B7-608]/UCR/Costa RicaDireccion General de Asuntos del Personal Academico/[IN203118]/DGAPA/MéxicoDireccion General de Asuntos del Personal Academico/[IN207218]/DGAPA/MéxicoUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ciencias de la Salud::Instituto Clodomiro Picado (ICP

    Strategies in 'snake venomics' aiming at an integrative view of compositional, functional, and immunological characteristics of venoms

    Get PDF
    This work offers a general overview on the evolving strategies for the proteomic analysis of snake venoms, and discusses how these may be combined through diverse experimental approaches with the goal of achieving a more comprehensive knowledge on the compositional, toxic, and immunological characteristics of venoms. Some recent developments in this field are summarized, highlighting how strategies have evolved from the mere cataloguing of venom components (proteomics/venomics), to a broader exploration of their immunological (antivenomics) and functional (toxicovenomics) characteristics. Altogether, the combination of these complementary strategies is helping to build a wider, more integrative view of the life-threatening protein cocktails produced by venomous snakes, responsible for thousands of deaths every year.Ministerio de Economía y Competitividad/[BFU2013-42833-P]//EspañaUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ciencias de la Salud::Instituto Clodomiro Picado (ICP

    Polymeric Membrane Sensors for the Selective Determination of Metoclopramide Hydrochloride and their Applications to Pharmaceutical Analysis

    No full text
    Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while electrode using DOP shows a linear concentration range between 3.0×10-5 – 1.0×10-2 M and detection limit 6×10-6 M. The selectivity coefficient values were calculated for MCP with respect to different inorganic cations, sugars and amino acids using the MCP depending on TBP plasticizer which is also used for the determination of MCP in pure solutions and in pharmaceutical preparations by direct, standard addition methods and as an indicator electrode in potentiometric titration with phosphotungstic acid (PT) giving satisfactory results. Key words: Metoclopramide-HCl membrane sensors , Metoclopramide determination , pharmaceutical analysis , PVC membrane sensors

    ОБҐРУНТУВАННЯ ВИМОГ ДО ЕФЕКТИВНОСТІ СИСТЕМИ ВІЙСЬКОВОГО ЗВ’ЯЗКУ

    No full text
    In the article the method of ground of requirements is examined to the efеct military communication network. The ground of requirements is executed with the use of the mathematical model developed authors. It is shown that the task of ground of requirements is taken to the task of the linear programming. The task of ground of requirements decides a simplex method. On the basis of this method an algorithm and program is developed in the environment of DELPHI. With the use of the developed software the ground of requirements is executed to the effect military communication network in the conversational model.У статті розглядається методика обґрунтування вимог до ефективності системи військового зв’язку. Обґрунтування здійснюється з використанням розробленої авторами математичної моделі. Показано, що задача обґрунтування вимог зводиться до задачі лінійного програмування, яка розв’язується симплексним методом. За цим методом розроблені алгоритм і програма у середовищі DELPHI. З їх допомогою обґрунтовано вимоги до ефективності системи військового зв’язку у діалоговому режимі

    Frequency of use and adequacy of Cochrane risk of bias tool 2 in non-Cochrane systematic reviews published in 2020: Meta-research study

    No full text
    Risk of bias (RoB) assessment is essential to the systematic review methodology. The new version of the Cochrane RoB tool for randomized trials (RoB 2) was published in 2019 to address limitations identified since the first version of the tool was published in 2008 and to increase the reliability of assessments. This study analyzed the frequency of usage of the RoB 2 and the adequacy of reporting the RoB 2 assessments in non-Cochrane reviews published in 2020. This meta-research study included non-Cochrane systematic reviews of interventions published in 2020. For the reviews that used the RoB 2 tool, we analyzed the reporting of the RoB 2 assessment. Among 3880 included reviews, the Cochrane RoB 1 tool was the most frequently used (N = 2228; 57.4%), followed by the Cochrane RoB 2 tool (N = 267; 6.9%). From 267 reviews that reported using the RoB 2 tool, 213 (79.8%) actually used it. In 26 (12.2%) reviews, erroneous statements were used to indicate the RoB 2 assessment. Only 20 (9.4%) reviews presented a complete RoB 2 assessment with a detailed table of answers to all signaling questions. The judgment of risk of bias by the RoB 2 tool was not justified by a comment in 158 (74.2%) reviews. Only in 33 (14.5%) of reviews the judgment in all domains was justified in the accompanying comment. In most reviews (81.7%), the RoB was inadequately assessed at the study level. In conclusion, the majority of non-Cochrane reviews published in 2020 still used the Cochrane RoB 1 tool. Many reviews used the RoB 2 tool inadequately. Further studies about the uptake and the use of the RoB 2 tool are needed. © 2024 John Wiley & Sons Ltd
    corecore