84 research outputs found

    Is Hyperopia an Important Risk Factor for PACG in the Dutch Population?—A Case Control Study

    Get PDF
    Objectives. To determine if hyperopia is a risk factor for primary angle-closure glaucoma (PACG) in the Dutch population and to identify other biometrical parameters as risk factors for PACG including axial length (AL), anterior chamber depth (ACD), and k values. Methods. The study population consisted of PACG patients that had undergone a laser peripheral iridotomy (LPI). The control group consisted of age- and gender-matched cataract patients. The main outcome was hyperopia (spherical equivalent ≥+0.5 dioptres) measured with IOL Master or autorefractor. Refractive error, ACD, AL, and k values were tested with a Mann-Whitney U test and by logistic regression. Results. 117 PACG patients and 234 controls were included (mean age = 80 years ± 3.6). The prevalence of hyperopia in patients and controls was 69.6% and 61.1%, respectively (Fisher’s test P=0.076). Mann-Whitney U test showed no statistically significant relation with refractive error (P=0.068) or k values (P=0.607). In contrast, ACD and AL were statistically significant (P<0.001). Tested with logistic regression, only ACD was a significant predictor of PACG (P<0.001). Conclusion. There was no statistically significant correlation between refractive error and PACG. ACD was strongly correlated, though, with PACG, whereas AL turned out to be a less significant risk factor

    Effect of ethnic diversity on the saccadic reaction time among healthy Indian and Dutch adults

    Get PDF
    Eye movement perimetry (EMP) expresses the decline in visual field (VF) responsiveness based on the deviation in saccadic reaction times (SRTs) from their expected age-similar responses (normative database). Since ethnic dissimilarities tend to affect saccade parameters, we evaluated the effect of such a factor on SRT and its interaction with age, stimulus eccentricity, and intensity. 149 healthy adults, spread into five age groups, drawn from Indian and Dutch ethnicities underwent a customized EMP protocol integrated with a saccade task from which the SRTs to ‘seen’ visual stimuli were computed. The EMP test had a total of 54 coordinates (five stimulus eccentricities) tested using Goldmann size III visual stimuli presented at four stimulus intensity (SI) levels against a constant background. Considering SRT as a dependent variable, a Generalized Linear Mixed Model analysis was conducted that revealed a statistically significant (p &lt; 0.001) influence of ethnicity and interaction between the tested factors (ethnicity × age × stimulus eccentricity × intensity). However, during the post hoc analysis, out of the 100 possible pair-wise comparisons, only 6% (minor proportion) of the estimates showed statistical significance. Hence, the ethnic-specific differences need not be accounted for while implementing EMP in a diverse set of populations instead a collective database might serve the purpose.</p

    Effect of ethnic diversity on the saccadic reaction time among healthy Indian and Dutch adults

    Get PDF
    Eye movement perimetry (EMP) expresses the decline in visual field (VF) responsiveness based on the deviation in saccadic reaction times (SRTs) from their expected age-similar responses (normative database). Since ethnic dissimilarities tend to affect saccade parameters, we evaluated the effect of such a factor on SRT and its interaction with age, stimulus eccentricity, and intensity. 149 healthy adults, spread into five age groups, drawn from Indian and Dutch ethnicities underwent a customized EMP protocol integrated with a saccade task from which the SRTs to ‘seen’ visual stimuli were computed. The EMP test had a total of 54 coordinates (five stimulus eccentricities) tested using Goldmann size III visual stimuli presented at four stimulus intensity (SI) levels against a constant background. Considering SRT as a dependent variable, a Generalized Linear Mixed Model analysis was conducted that revealed a statistically significant (p &lt; 0.001) influence of ethnicity and interaction between the tested factors (ethnicity × age × stimulus eccentricity × intensity). However, during the post hoc analysis, out of the 100 possible pair-wise comparisons, only 6% (minor proportion) of the estimates showed statistical significance. Hence, the ethnic-specific differences need not be accounted for while implementing EMP in a diverse set of populations instead a collective database might serve the purpose.</p

    A very short version of the Visual Function Questionnaire (VFQ-3oo7) for use as a routinely applied Patient-Reported Outcome Measure

    Get PDF
    Background: Patient-reported outcome measures (PROMs) are valuable supplements in regular care to facilitate routine monitoring of quality of life from the patient’s perspective. The 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) is a widely used PROM in ophthalmology. However, the NEI-VFQ-25 is too time-consuming and cumbersome for routine evaluations in regular care. The aim of this study is to construct a 7-item questionnaire of which only 3 items are presented to the patient, by means of routing. This VFQ 3 out of 7 (VFQ-3oo7) should have a minimal loss of information compared with the NEI-VFQ-25. Methods: An historical database including 3293 administrations of the NEI-VFQ-25 was constructed involving patients with retinal detachment, cataract, corneal diseases, glaucoma, macular degeneration, uveal melanoma and a normal population sample. The data were subjected to Rasch analyses, in particular a generalized partial credit model. Items were sorted on the latent trait and divided into seven categories. From each category, the item with the highest discriminative value was selected. Through routing, only three out of the seven remaining questions are used, where the answers navigate patients to a fitting trait level. Results: A one-dimensional structure was considered fitting. The VFQ-3oo7 showed a small loss of information compared with the total score of the NEI-VFQ-25: correlation 0.927 and a relative precision of 0.868. Conclusion: The very short, but valid, VFQ-3oo7 can be applied to evaluate the patient's perceived vision-related health status in routine evaluations of treatments in regular care, with a small burden for patients

    Bayesian hierarchical modeling of longitudinal glaucomatous visual fields using a two-stage approach

    Get PDF
    The Bayesian approach has become increasingly popular because it allows to fit quite complex models to data via Markov chain Monte Carlo sampling. However, it is also recognized nowadays that Markov chain Monte Carlo sampling can become computationally prohibitive when applied to a large data set. We encountered serious computational difficulties when fitting an hierarchical model to longitudinal glaucoma data of patients who participate in an ongoing Dutch study. To overcome this problem, we applied and extended a recently proposed two-stage approach to model these data. Glaucoma is one of the leading causes of blindness in the world. In order to detect deterioration at an early stage, a model for predicting visual fields (VFs) in time is needed. Hence, the true underlying VF progression can be determined, and treatment strategies can then be optimized to prevent further VF loss. Because we were unable to fit these data with the classical one-stage approach upon which the current popular Bayesian software is based, we made use of the two-stage Bayesian approach. The considered hierarchical longitudinal model involves estimating a large number of random effects and deals with censoring and high measurement variability. In addition, we extended the approach with tools for model evaluation. Copyrigh

    Differences in clinical presentation of primary open-angle glaucoma between African and European populations

    Get PDF
    PURPOSE: Primary open‐angle glaucoma (POAG) has been reported to occur more frequently in Africans, and to follow a more severe course compared to Europeans. We aimed to describe characteristics of POAG presentation and treatment across three ethnic groups from Africa and one from Europe. METHODS: We ascertained 151 POAG patients from South African Coloured (SAC) and 94 South African Black (SAB) ethnicity from a university hospital in South Africa. In Tanzania, 310 patients were recruited from a university hospital and a referral hospital. In the Netherlands, 241 patients of European ancestry were included. All patients were over 35 years old and had undergone an extensive ophthalmic examination. Patients were diagnosed according to the ISGEO criteria. A biogeographic ancestry analysis was performed to estimate the proportion of genetic African ancestry (GAA). RESULTS: The biogeographic ancestry analysis showed that the median proportion of GAA was 97.6% in Tanzanian, 100% in SAB, 34.2% in SAC and 1.5% in Dutch participants. Clinical characteristics at presentation for Tanzanians, SAB, SAC and Dutch participants, respectively: mean age: 63, 57, 66, 70 years (p < 0.001); visual acuity in the worse eye: 1.78, 1.78, 0.3, 0.3 LogMAR (p < 0.001); maximum intraocular pressure of both eyes: 36, 34, 29, 29 mmHg (p (anova)  < 0.001); maximum vertical cup to disc ratio (VCDR) of both eyes: 0.90, 0.90, 0.84, 0.83 (p < 0.001); mean central corneal thickness: 506, 487, 511, 528 μm (p < 0.001). Fourteen percent of Tanzanian patients presented with blindness (<3/60 Snellen) in the better eye in contrast to only 1% in the Dutch. CONCLUSION: In this multi‐ethnic comparative study, Sub‐Saharan Africans present at a younger age with lower visual acuity, higher IOP, larger VCDR, than SAC and Dutch participants. This indicates the more progressive and destructive course in Sub‐Saharan Africans

    Assessment of optic disc photographs for glaucoma by UK optometrists: The Moorfields Optic Disc Assessment Study (MODAS)

    Get PDF
    Purpose: To assess the ability of UK optometrists to accurately discriminate between stereoscopic photographs of healthy and glaucomatous optic discs. Methods: An online survey, including questions relating to qualification, practice environment, and diagnostic methods was completed by 1256 optometrists. Based on their responses, 208 (17%) were selected to undertake an online disc assessment exercise. Optometrists evaluated the same disc images previously assessed by European ophthalmologists as part of the European Optic Disc Assessment Trial (EODAT); the task was to state if the disc appeared healthy or glaucomatous. There were 110 stereoscopic disc images, of which 40 were healthy, 48 glaucomatous, and six ocular hypertensive, with 16 duplicates images. Sensitivity, specificity and overall accuracy were calculated and compared between optometrist groups and with the EODAT ophthalmologists using permutation analysis. Results: Median sensitivity was 0.92 (95% CI: 0.70, 1.00) and median specificity was 0.74 (95% CI: 0.62, 0.88). Median overall accuracy was 80% (95% CI: 67%, 88%). Agreement between optometrists was moderate (Fleiss' κ: 0.57). Optometrists with higher qualifications did not have overall higher sensitivity than those without (p = 0.23), but had higher specificity (p = 0.001) and higher overall accuracy (p < 0.001). Optometrists displayed higher sensitivity but lower specificity than the EODAT ophthalmologists. Conclusion: UK optometrists displayed a high sensitivity and moderate specificity when assessing optic discs for the presence of glaucoma, in the context of this study
    corecore