20 research outputs found

    Neck fracture of a cementless forged titanium alloy femoral stem following total hip arthroplasty: a case report and review of the literature

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature.</p> <p>Case presentation</p> <p>This case report describes a fracture of the neck of a cementless forged titanium alloy stem coated in the proximal third with hydroxy-apatite.</p> <p>Conclusion</p> <p>The neck of the femoral stem failed from fatigue probably because of a combination of factors described analytically below.</p

    Forefoot plantar multilobular noninfiltrating angiolipoma: a case report and review of the literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Soft tissue tumors of the feet are uncommon and there have been very few reports of large series in the literature. These tumors continue to present the clinician with one of the most difficult problems in medicine.</p> <p>Case presentation</p> <p>We present a case of a large multilobular noninfiltrating angiolipoma at the plantar surface of the forefoot. Only three cases occurring at the foot have been previously described. We report this new case due to unusual location of the tumor, the long duration (25 years) of its existence and the unique surgical approach for the tumor excision.</p> <p>Conclusion</p> <p>Surgical excision is the treatment of choice and adjuvant radiotherapy is indicated in select cases.</p

    Posterior Spinal Fusion Using Pedicle Screws

    No full text
    Few clinical studies have reported polyetheretherketone (PEEK) rod pedicle screw spinal instrumentation systems (CD-Horizon Legacy PEEK rods; Medtronic, Minneapolis, Minnesota). This article describes a clinical series of 52 patients who underwent posterior spinal fusion using the PEEK Rod System between 2007 and 2010. Of the 52 patients, 25 had degenerative disk disease, 10 had lateral recess stenosis, 6 had degenerative spondylolisthesis, 6 had lumbar spine vertebral fracture, 4 had combined lateral recess stenosis and degenerative spondylolisthesis, and 1 had an L5 giant cell tumor. Ten patients had 1-segment fusion, 29 had 2-segment fusion, and 13 had 3-segment fusion. Mean follow-up was 3 years (range, 1.5-4 years); no patient was lost to follow-up. Clinical evaluation was performed using the Oswestry Disability Index and a low back and leg visual analog pain scale. Imaging evaluation of fusion was performed with standard and dynamic radiographs. Complications were recorded. Mean Oswestry Disability Index scores improved from 76% preoperatively (range, 52%-90%) to 48% at 6 weeks postoperatively, and to 34%, 28%, and 30% at 3, 6, and 12 months postoperatively, respectively. Mean low back and leg pain improved from 8 and 9 points preoperatively, respectively, to 6 and 5 points immediately postoperatively, respectively, and to 2 points each thereafter. Imaging union of the arthrodesis was observed in 50 (96%) patients by 1-year follow-up. Two patients sustained screw breakage: 1 had painful loss of sagittal alignment of the lumbar spine and underwent revision spinal surgery with pedicle screws and titanium rods and the other had superficial wound infection and was treated with wound dressing changes and antibiotics for 6 weeks. No adjacent segment degeneration was observed in any patient until the time of this writing
    corecore