36 research outputs found
ΠΠΎΠ΄Ρ ΠΎΠ΄ ΠΊ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠΊΠ΅ ΠΈΠ½ΡΠ΅Π³ΡΠΈΡΠΎΠ²Π°Π½Π½ΠΎΠΉ ΡΠΈΡΡΠ΅ΠΌΡ ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° Π½Π° Ρ ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΈΡ ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡΡ .
On the base of systems approach the selection task of integrated management system structure was analyzed. Integrated management system on the chemical enterprises includes as a rule several systems: quality management system as a base system, environmental protection system, professional safety and employment protection system, GMP system, etc. It was suggested the solve method of structure selection task and business-processes distribution among enterprise departmentsΠΡΠΎΠ°Π½Π°Π»ΠΈΠ·ΠΈΡΠΎΠ²Π°Π½Π° Π·Π°Π΄Π°ΡΠ° Π²ΡΠ±ΠΎΡΠ° ΡΡΡΡΠΊΡΡΡΡ ΠΈΠ½ΡΠ΅Π³ΡΠΈΡΠΎΠ²Π°Π½Π½ΠΎΠΉ ΡΠΈΡΡΠ΅ΠΌΡ ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° (ΠΠ‘Π) Ρ
ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡ. ΠΠ½ΡΠ΅Π³ΡΠΈΡΠΎΠ²Π°Π½Π½Π°Ρ ΡΠΈΡΡΠ΅ΠΌΠ° ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° (ΠΠ‘Π) Π½Π° Ρ
ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡΡ
, ΠΊΠ°ΠΊ ΠΏΡΠ°Π²ΠΈΠ»ΠΎ, Π²ΠΊΠ»ΡΡΠ°Π΅Ρ Π½Π΅ΡΠΊΠΎΠ»ΡΠΊΠΎ ΠΏΠΎΠ΄ΡΠΈΡΡΠ΅ΠΌ: ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° ΠΊΠ°ΡΠ΅ΡΡΠ²Π° ΠΊΠ°ΠΊ Π±Π°Π·ΠΎΠ²ΡΡ ΡΠΈΡΡΠ΅ΠΌΡ, ΡΠΈΡΡΠ΅ΠΌΡ ΠΎΡ
ΡΠ°Π½Ρ ΠΎΠΊΡΡΠΆΠ°ΡΡΠ΅ΠΉ ΡΡΠ΅Π΄Ρ, ΡΠΈΡΡΠ΅ΠΌΡ ΠΏΡΠΎΡΠ΅ΡΡΠΈΠΎΠ½Π°Π»ΡΠ½ΠΎΠΉ Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡΠΈ ΠΈ ΠΎΡ
ΡΠ°Π½Ρ ΡΡΡΠ΄Π°, ΡΠΈΡΡΠ΅ΠΌΡ GMP ΠΈ Ρ.ΠΏ. ΠΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½ ΠΌΠ΅ΡΠΎΠ΄ ΡΠ΅ΡΠ΅Π½ΠΈΡ Π·Π°Π΄Π°ΡΠΈ Π²ΡΠ±ΠΎΡΠ° ΡΡΡΡΠΊΡΡΡΡ ΠΈ ΡΠ°ΡΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Π±ΠΈΠ·Π½Π΅Ρ-ΠΏΡΠΎΡΠ΅ΡΡΠΎΠ² ΠΏΠΎ ΠΏΠΎΠ΄ΡΠ°Π·Π΄Π΅Π»Π΅Π½ΠΈΡΠΌ Ρ ΡΡΠ΅ΡΠΎΠΌ ΠΎΡΠΎΠ±Π΅Π½Π½ΠΎΡΡΠ΅ΠΉ Ρ
ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡ
ΠΠ½Π°Π»ΠΈΠ· ΠΈ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠΊΠ° ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΉ ΠΏΠΎ ΡΠΎΠ²Π΅ΡΡΠ΅Π½ΡΡΠ²ΠΎΠ²Π°Π½ΠΈΡ Π΄Π΅ΠΉΡΡΠ²ΡΡΡΠ΅ΠΉ ΠΈΠ½ΡΠ΅Π³ΡΠΈΡΠΎΠ²Π°Π½Π½ΠΎΠΉ ΡΠΈΡΡΠ΅ΠΌΡ ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° Ρ ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΎΠ³ΠΎ ΠΏΡΠ΅Π΄ΠΏΡΠΈΡΡΠΈΡ
The integrated management system (IMS) process model of Saratovorgsintez, Ltd. has been built. The system includes quality management subsystem, environmental protection subsystem, employment protection subsystem. Probable fields for improvement of Saratovorgsintez, Ltd. system has been shown. IMS improvement recommendations has been also developed.ΠΠΎΡΡΡΠΎΠ΅Π½Π° ΠΏΡΠΎΡΠ΅ΡΡΠ½Π°Ρ ΠΌΠΎΠ΄Π΅Π»Ρ ΠΈΠ½ΡΠ΅Π³ΡΠΈΡΠΎΠ²Π°Π½Π½ΠΎΠΉ ΡΠΈΡΡΠ΅ΠΌΡ ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° (ΠΠ‘Π) ΠΠΠ Β«Π‘Π°ΡΠ°ΡΠΎΠ²ΠΎΡΠ³ΡΠΈΠ½ΡΠ΅Π·Β», Π²ΠΊΠ»ΡΡΠ°ΡΡΠ°Ρ ΠΏΠΎΠ΄ΡΠΈΡΡΠ΅ΠΌΡ ΠΌΠ΅Π½Π΅Π΄ΠΆΠΌΠ΅Π½ΡΠ° ΠΊΠ°ΡΠ΅ΡΡΠ²Π°, ΠΎΡ
ΡΠ°Π½Ρ ΠΎΠΊΡΡΠΆΠ°ΡΡΠ΅ΠΉ ΡΡΠ΅Π΄Ρ, ΠΏΡΠΎΡΠ΅ΡΡΠΈΠΎΠ½Π°Π»ΡΠ½ΠΎΠΉ Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡΠΈ ΠΈ ΠΎΡ
ΡΠ°Π½Ρ ΡΡΡΠ΄Π°. ΠΠΎΠΊΠ°Π·Π°Π½Ρ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΡΠ΅ ΠΎΠ±Π»Π°ΡΡΠΈ Π΄Π»Ρ ΡΠ»ΡΡΡΠ΅Π½ΠΈΡ ΡΠΈΡΡΠ΅ΠΌΡ ΠΠΠ Β«Π‘Π°ΡΠ°ΡΠΎΠ²ΠΎΡΠ³ΡΠΈΠ½ΡΠ΅Π·Β» ΠΈ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠ°Π½Ρ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΈ ΠΏΠΎ ΡΠΎΠ²Π΅ΡΡΠ΅Π½ΡΡΠ²ΠΎΠ²Π°Π½ΠΈΡ ΠΠ‘Π
ΠΡΠΎΠ±Π»Π΅ΠΌΡ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠΊΠΈ Π½ΠΎΠ²ΡΡ Π½Π°ΡΠΈΠΎΠ½Π°Π»ΡΠ½ΡΡ ΡΡΠ°Π½Π΄Π°ΡΡΠΎΠ² Π½Π° ΠΌΠ΅ΡΠΎΠ΄Ρ Π°Π½Π°Π»ΠΈΠ·Π° Π±Π»Π°Π³ΠΎΡΠΎΠ΄Π½ΡΡ ΠΌΠ΅ΡΠ°Π»Π»ΠΎΠ² ΠΈ ΠΈΡ ΡΠΏΠ»Π°Π²ΠΎΠ²
A review of the currently effective Russian national standards for methods of platinum metal and alloy analysis has been made, many of the standards being obsolete as for their content and the analytical procedures used. Some problems of the development of the new national standards have been described and the way of problem solving has been suggested.ΠΡΠΈΠ²Π΅Π΄Π΅Π½ ΠΎΠ±Π·ΠΎΡ Π΄Π΅ΠΉΡΡΠ²ΡΡΡΠΈΡ
Π½Π°ΡΠΈΠΎΠ½Π°Π»ΡΠ½ΡΡ
ΡΡΠ°Π½Π΄Π°ΡΡΠΎΠ² Π½Π° ΠΌΠ΅ΡΠΎΠ΄Ρ Π°Π½Π°Π»ΠΈΠ·Π° Π±Π»Π°Π³ΠΎΡΠΎΠ΄Π½ΡΡ
ΠΌΠ΅ΡΠ°Π»Π»ΠΎΠ² ΠΈ ΠΈΡ
ΡΠΏΠ»Π°Π²ΠΎΠ², ΠΌΠ½ΠΎΠ³ΠΈΠ΅ ΠΈΠ· ΠΊΠΎΡΠΎΡΡΡ
ΡΡΡΠ°ΡΠ΅Π»ΠΈ Π½Π΅ ΡΠΎΠ»ΡΠΊΠΎ ΠΏΠΎ ΡΠΎΡΠΌΠ΅ ΠΈ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΡ, Π½ΠΎ ΠΈ ΠΏΠΎ ΡΡΡΠ΅ΡΡΠ²Ρ ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΠ΅ΠΌΡΡ
ΠΌΠ΅ΡΠΎΠ΄ΠΈΠΊ Π°Π½Π°Π»ΠΈΠ·Π°. Π Π°ΡΡΠΌΠΎΡΡΠ΅Π½Ρ ΠΏΡΠΎΠ±Π»Π΅ΠΌΡ ΠΈ ΠΏΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½Ρ ΠΏΡΡΠΈ ΡΠ°Π·ΡΠ°Π±ΠΎΡΠΊΠΈ Π½ΠΎΠ²ΡΡ
Π½Π°ΡΠΈΠΎΠ½Π°Π»ΡΠ½ΡΡ
ΡΡΠ°Π½Π΄Π°ΡΡΠΎΠ²
ΠΠ°ΡΠ°Π»ΠΈΡΠΈΡΠ΅ΡΠΊΠΈΠΉ ΡΠ΅ΡΡ-ΠΌΠ΅ΡΠΎΠ΄ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΠΌΠΈΠΊΡΠΎΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ² ΡΡΡΠ΅Π½ΠΈΡ Π½Π° ΠΎΡΠ½ΠΎΠ²Π΅ ΡΠ΅Π°ΠΊΡΠΈΠΈ ΠΎΠΊΠΈΡΠ»Π΅Π½ΠΈΡ ΠΌΠ΅ΡΠΈΠ»ΠΎΠ²ΠΎΠ³ΠΎ ΠΎΡΠ°Π½ΠΆΠ΅Π²ΠΎΠ³ΠΎ ΠΏΠ΅ΡΠΈΠΎΠ΄Π°ΡΠΎΠΌ ΠΊΠ°Π»ΠΈΡ
A catalytic test-method for the determination of ruthenium based on methyl orange oxidation by potassium periodate at pH =1 on a paper carrier was proposed. The conditions for the indicator reaction performance were optimized. It is possible to determine ruthenium in the range of its concentrations 0.010 Γ· 0.55 Β΅g/ml .The detection limit equals to 0.0035 Β΅g/ml, the relative standard deviation (RSD) is not higher than 0.058. The accuracy of the analysis results was confirmed by the traditional added - found method.ΠΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½ ΡΠ΅ΡΡ-ΠΌΠ΅ΡΠΎΠ΄ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΡΡΠ΅Π½ΠΈΡ, ΠΎΡΠ½ΠΎΠ²Π°Π½Π½ΡΠΉ Π½Π° ΠΏΡΠΎΠ²Π΅Π΄Π΅Π½ΠΈΠΈ ΠΊΠ°ΡΠ°Π»ΠΈΡΠΈΡΠ΅ΡΠΊΠΎΠΉ ΠΈΠ½Π΄ΠΈΠΊΠ°ΡΠΎΡΠ½ΠΎΠΉ ΡΠ΅Π°ΠΊΡΠΈΠΈ ΠΎΠΊΠΈΡΠ»Π΅Π½ΠΈΡ ΠΌΠ΅ΡΠΈΠ»ΠΎΠ²ΠΎΠ³ΠΎ ΠΎΡΠ°Π½ΠΆΠ΅Π²ΠΎΠ³ΠΎ ΠΏΠ΅ΡΠΈΠΎΠ΄Π°ΡΠΎΠΌ ΠΊΠ°Π»ΠΈΡ ΠΏΡΠΈ pH 1 Π½Π° Π±ΡΠΌΠ°ΠΆΠ½ΠΎΠΌ Π½ΠΎΡΠΈΡΠ΅Π»Π΅. ΠΡΠ±ΡΠ°Π½ ΠΎΠΏΡΠΈΠΌΠ°Π»ΡΠ½ΡΠΉ Π²Π°ΡΠΈΠ°Π½Ρ ΠΏΡΠΎΠ²Π΅Π΄Π΅Π½ΠΈΡ ΡΠ΅Π°ΠΊΡΠΈΠΈ. ΠΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΠ΅ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎ Π² ΡΠΈΡΠΎΠΊΠΎΠΌ Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ ΠΊΠΎΠ½ΡΠ΅Π½ΡΡΠ°ΡΠΈΠΉ ΡΡΡΠ΅Π½ΠΈΡ: 0.010 Π΄ΠΎ 0.55 ΠΌΠΊΠ³/ΠΌΠ». ΠΡΠ΅Π΄Π΅Π» ΠΎΠ±Π½Π°ΡΡΠΆΠ΅Π½ΠΈΡ ΡΠΎΡΡΠ°Π²Π»ΡΠ΅Ρ 0.0035 ΠΌΠΊΠ³/ΠΌΠ», ΠΎΡΠ½ΠΎΡΠΈΡΠ΅Π»ΡΠ½ΠΎΠ΅ ΡΡΠ°Π½Π΄Π°ΡΡΠ½ΠΎΠ΅ ΠΎΡΠΊΠ»ΠΎΠ½Π΅Π½ΠΈΠ΅ Π½Π΅ ΠΏΡΠ΅Π²ΡΡΠ°Π΅Ρ 0.058. ΠΡΠ°Π²ΠΈΠ»ΡΠ½ΠΎΡΡΡ ΡΠ΅Π·ΡΠ»ΡΡΠ°ΡΠΎΠ² Π°Π½Π°Π»ΠΈΠ·Π° ΠΏΠΎ ΠΏΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½Π½ΠΎΠΉ ΠΌΠ΅ΡΠΎΠ΄ΠΈΠΊΠ΅ ΠΏΠΎΠ΄ΡΠ²Π΅ΡΠΆΠ΄Π΅Π½Π° ΠΌΠ΅ΡΠΎΠ΄ΠΎΠΌ Β«Π²Π²Π΅Π΄Π΅Π½ΠΎ-Π½Π°ΠΉΠ΄Π΅Π½ΠΎΒ»
ΠΠΎΠ΄Π³ΠΎΡΠΎΠ²ΠΊΠ° ΡΠΏΠ΅ΡΠΈΠ°Π»ΠΈΡΡΠΎΠ² ΠΈ ΠΌΠ°Π³ΠΈΡΡΡΠΎΠ² ΠΏΠΎ ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΠΈ, ΡΡΠ°Π½Π΄Π°ΡΡΠΈΠ·Π°ΡΠΈΠΈ ΠΈ ΡΠ΅ΡΡΠΈΡΠΈΠΊΠ°ΡΠΈΠΈ
In work advantages of engineers and masters education of the higher engineering school in metrology, standardization and certification in the conditions of multilevel structure of the basic educational programs in the Moscow state academy of fine chemical technology named after M.V. Lomonosov are openedΠ ΡΠ°Π±ΠΎΡΠ΅ ΡΠ°ΡΠΊΡΡΡΡ ΠΏΡΠ΅ΠΈΠΌΡΡΠ΅ΡΡΠ²Π° ΠΏΠΎΠ΄Π³ΠΎΡΠΎΠ²ΠΊΠΈ ΠΌΠ°Π³ΠΈΡΡΡΠΎΠ² ΠΈ ΡΠΏΠ΅ΡΠΈΠ°Π»ΠΈΡΡΠΎΠ² Π²ΡΡΡΠ΅ΠΉ ΠΈΠ½ΠΆΠ΅Π½Π΅ΡΠ½ΠΎΠΉ ΡΠΊΠΎΠ»Ρ ΠΏΠΎ ΠΌΠ΅ΡΡΠΎΠ»ΠΎΠ³ΠΈΠΈ, ΡΡΠ°Π½Π΄Π°ΡΡΠΈΠ·Π°ΡΠΈΠΈ ΠΈ ΡΠ΅ΡΡΠΈΡΠΈΠΊΠ°ΡΠΈΠΈ Π² ΡΡΠ»ΠΎΠ²ΠΈΡΡ
ΠΌΠ½ΠΎΠ³ΠΎΡΡΠΎΠ²Π½Π΅Π²ΠΎΠΉ ΡΡΡΡΠΊΡΡΡΡ ΠΎΡΠ½ΠΎΠ²Π½ΡΡ
ΠΎΠ±ΡΠ°Π·ΠΎΠ²Π°ΡΠ΅Π»ΡΠ½ΡΡ
ΠΏΡΠΎΠ³ΡΠ°ΠΌΠΌ Π² ΠΠΎΡΠΊΠΎΠ²ΡΠΊΠΎΠΉ Π°ΠΊΠ°Π΄Π΅ΠΌΠΈΠΈ ΡΠΎΠ½ΠΊΠΎΠΉ Ρ
ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΎΠΉ ΡΠ΅Ρ
Π½ΠΎΠ»ΠΎΠ³ΠΈΠΈ ΠΈΠΌΠ΅Π½ΠΈ Π.Π. ΠΠΎΠΌΠΎΠ½ΠΎΡΠΎΠ²
Analysis and recommendations development for improvement of active chemical enterprise integrated management system.
The integrated management system (IMS) process model of Saratovorgsintez, Ltd. has been built. The system includes quality management subsystem, environmental protection subsystem, employment protection subsystem. Probable fields for improvement of Saratovorgsintez, Ltd. system has been shown. IMS improvement recommendations has been also developed
Catalytic test-method for determination of ruthenium microquantities based on methyl orange oxidation with potassium periodate
A catalytic test-method for the determination of ruthenium based on methyl orange oxidation by potassium periodate at pH =1 on a paper carrier was proposed. The conditions for the indicator reaction performance were optimized. It is possible to determine ruthenium in the range of its concentrations 0.010 Γ· 0.55 Β΅g/ml .The detection limit equals to 0.0035 Β΅g/ml, the relative standard deviation (RSD) is not higher than 0.058. The accuracy of the analysis results was confirmed by the traditional added - found method
Some problems of the development of new national standards for methods of platinum metals and alloys analysis.
A review of the currently effective Russian national standards for methods of platinum metal and alloy analysis has been made, many of the standards being obsolete as for their content and the analytical procedures used. Some problems of the development of the new national standards have been described and the way of problem solving has been suggested
Studying of student satisfaction within operation of quality management system of higher educational institution
ΠΡΠ΅Π΄ΡΡΠ°Π²Π»Π΅Π½Π° ΠΌΠ΅ΡΠΎΠ΄ΠΈΠΊΠ° ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ ΡΠ΄ΠΎΠ²Π»Π΅ΡΠ²ΠΎΡΠ΅Π½Π½ΠΎΡΡΠΈ ΡΡΡΠ΄Π΅Π½ΡΠΎΠ², ΠΎΡΠΈΠ΅Π½ΡΠΈΡΠΎΠ²Π°Π½Π½Π°Ρ Π½Π° Π·Π°ΠΏΡΠΎΡΡ ΠΏΠΎΡΡΠ΅Π±ΠΈΡΠ΅Π»Π΅ΠΉ. ΠΠ΅ΡΠ°Π»ΡΠ½ΠΎ ΠΎΠΏΠΈΡΡΠ²Π°Π΅ΡΡΡ ΡΠ΅Π°Π»ΠΈΠ·Π°ΡΠΈΡ Π²ΡΠ΅Ρ
ΡΡΠ°ΠΏΠΎΠ² ΠΌΠ΅ΡΠΎΠ΄ΠΈΠΊΠΈ, Π°ΠΊΡΠ΅Π½ΡΠΈΡΡΠ΅ΡΡΡ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅ Π½Π° ΠΏΡΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠΈ ΡΡΠ°ΡΠΈΡΡΠΈΡΠ΅ΡΠΊΠΈΡ
ΠΌΠ΅ΡΠΎΠ΄ΠΎΠ² Π½Π° Π²ΡΠ΅Ρ
ΡΡΠ°ΠΏΠ°Ρ
ΠΏΠ»Π°Π½ΠΈΡΠΎΠ²Π°Π½ΠΈΡ ΠΈ ΡΠ΅Π°Π»ΠΈΠ·Π°ΡΠΈΠΈ ΠΈΡΡΠ»Π΅Π΄ΠΎΠ²Π°Π½ΠΈΡ ΡΠ΄ΠΎΠ²Π»Π΅ΡΠΎΡΠ΅Π½Π½ΠΎΡΡΠΈ ΡΡΡΠ΄Π΅Π½ΡΠΎΠ².This article presents the methodology of student satisfaction study focused on customer needs. Realization of all the methodology stages, focusing on the application of statistical methods at all stages of planning and implementation of students satisfaction studying is in details described