    Automated RIBA Hepatitis C Virus (HCV) Strip Immunoblot Assay for Reproducible HCV Diagnosis

    No full text
    A comparison between the CHIRON RIBA hepatitis C virus (HCV) processor and manual systems was performed by using 88 specimens repeatedly reactive by the second-generation HCV enzyme-linked immunosorbent assay (ELISA) (HCV 2.0 ELISA) and 111 random specimens from volunteer donors. For the second-generation RIBA HCV strip immunoblot assay (SIA) (RIBA HCV 2.0 SIA), test results correlated strongly between the manual and the automated runs (kappa value, 0.937). For the RIBA HCV 3.0 SIA, the correlation of the test results was also high (kappa value, 0.899). Among the specimens with positive results by RIBA HCV 2.0 and 3.0 SIAs, there was a very strong concordance of the test results between the manual and the automated runs with regard to the reactive bands. Nine samples had discordant results between the manual and the automated runs; this was probably attributable to increased variability in antigen scores close to the cutoff values for both tests. Run-to-run and within-run testing by the CHIRON RIBA HCV Processor System showed a very low rate of conflicting values. In conclusion, the CHIRON RIBA HCV Processor System is capable of performing RIBA HCV 2.0 and 3.0 SIAs accurately with minimal operator involvement. In addition, the CHIRON RIBA HCV Processor System shows excellent reproducibility, with the potential for operator-to-operator and site-to-site variability being greatly reduced. Our data indicate that this novel methodology may be very useful for supplemental anti-HCV testing of specimens repeatedly reactive by ELISA in routine clinical assessments and epidemiologic evaluations

    Evaluation of a novel serotyping system for hepatitis C virus: strong correlation with standard genotyping methodologies.

    No full text
    Direct sequencing and analysis of viral genomes are definitive methods for identifying various hepatitis C virus (HCV) genotypes. However, HCV genome sequencing methods are cumbersome and unsuitable for analyzing large numbers of clinical samples. We have developed a convenient, reliable, and reproducible RIBA strip immunoblot assay system for determining HCV serotype. Briefly, the assay consists of an immunoblot strip on which there are five lanes of immobilized serotype-specific HCV peptides from the nonstructural (NS-4) and core regions of the genomes of HCV types 1,2, and 3. HCV serotype is deduced by determining the greatest intensity of reactivity to the NS-4 serotype-specific HCV peptide band in relation to the intensity of the human immunoglobulin G internal control bands on each strip. HCV core peptide reactivity is used only in the absence of NS-4 reactivity. We used this assay to successfully serotype a high percentage of sera from well-documented HCV-infected patients. Our serotyping results correlated 99% with the findings from the standard restriction fragment length polymorphism genotyping methods. Less than 5% of the serum samples were untypeable. For a selected group of alpha interferon-treated patients we observed that the nonresponders (76.2%) and a majority of the responders who relapsed (72.2%) had type 2 HCV infection. A small population (n= 8) of complete responders was split 3:4:1 as type 1, type 2, and type 3, respectively. Our data indicate that this new serotyping assay has the potential to be a highly specific and reliable method for typing of HCV infection in patients
    corecore