6,271 research outputs found

    An improved processible acetylene-terminated polyimide for composites

    Get PDF
    The newest member of a family of thermosetting acetylene-substituted polyimide oligomers is HR600P. This oligomer is the isoimide version of the oligomer known as HR600P and Thermid 600. Although both types of material yield the same heat resistant end products after cure, HR600P has much superior processing characteristics. This attributed to its lower melting temperature (160 + or - 10 C, 320 + or - 20 F) in contrast to 202 C (396 F) for Thermid MC-600, its longer gel time at its processing temperature (16 to 30 minutes bvs 3 minutes), and its excellent solubility in low boiling solvents such as tetrahydrofuran, glymes, or 4:1 methyl ethyl ketone/toluene mixtures. These advantages provide more acceptable coating and impregnation procedures, allow for more complete removal at lower temperatures, provide a longer pot life or working time, and allow composite structure fabrication in conventional autoclaves used for epoxy composite curing. The excellent processing characteristics of HR600P allow its use in large area laminated structures, structural composites, and molding compositions

    Establishment, Impacts, and Current Range of Spotted Knapweed (\u3ci\u3eCentaurea Stoebe\u3c/i\u3e Ssp. \u3ci\u3eMicranthos\u3c/i\u3e) Biological Control Insects in Michigan

    Get PDF
    Centaurea stoebe L. ssp. micranthos (Gugler) Hayek (spotted knapweed) is an invasive plant that has been the target of classical biological control in North America for more than four decades. Work in the western U.S. and Canada has shown the seedhead-feeding weevils Larinus minutus Gyllenhal and Larinus obtusus Gyllenhal (Coleoptera: Curculionidae) and the root-boring weevil Cyphocleonus achates (Fahraeus) (Coleoptera: Curculionidae) to be the most effective C. stoebe control agents. These three weevils have recently been introduced into the eastern U.S., including sites in Michigan in 2007 and 2009. In 2010, we made additional releases at six sites in Michigan, monitoring them for three years 2011-13. Here we report on the establishment, impact, and cur- rent range of L. minutus, L. obtusus, and C. achates in Michigan. We also report on the initial results of native plant overseeding treatments that were applied to biological control release sites with the aim of supplementing the nectar source C. stoebe provides. We found that L. minutus has established at all of its Michigan release sites and is widespread in the southwestern part of the state, while L. obtusus has established at the single site where it was released in 2007 and is spreading to adjoining counties. We also found C. achates to be present at four sites and established at one additional site in Michigan, but in all cases abundances are low and dispersal has been minimal (\u3c 10 m). In the three years following the 2010 releases, we found no measurable impacts of these biological control agents on C. stoebe growth, demographics, or plant community metrics. We also found little evidence of native flowering plant establishment at seeded sites. These baseline data will be useful in monitoring the spread and potential impacts of biological control agents on C. stoebe in Michigan

    Design considerations for lunar base photovoltaic power systems

    Get PDF
    A survey was made of factors that may affect the design of photovoltaic arrays for a lunar base. These factors, which include the lunar environment and system design criteria, are examined. A photovoltaic power system design with a triangular array geometry is discussed and compared to a nuclear reactor power systems and a power system utilizing both nuclear and solar power sources

    Size effects on exchange bias in sub-100 nm ferromagnetic-antiferromagnetic dots deposited on prepatterned substrates

    Get PDF
    This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.Exchange bias effects have been investigated in ferromagnetic (FM)-antiferromagnetic (AFM) square dots, with lateral sizes of 90 nm, sputtered on a prepatterned Si substrate. The magnetic behavior of the dots has been compared with that of a continuous FM-AFM bilayer with the same composition. Along the unidirectional direction, the dots exhibit square hysteresis loops and preserve an exchange bias field, HE, of 70 Oe at room temperature, which is about 40% smaller than HE in the continuous film. In addition, the distribution of blocking temperatures in the nanostructures is found to be shifted toward lower values with respect to that in the continuous film. These results can be interpreted assuming that the reduced lateral dimensions of the nanostructures impose some constraints on the formation and pinning of domain walls in the AFM layer

    CHD associated with syndromic diagnoses: peri-operative risk factors and early outcomes

    Get PDF
    CHD is frequently associated with a genetic syndrome. These syndromes often present specific cardiovascular and non-cardiovascular co-morbidities that confer significant peri-operative risks affecting multiple organ systems. Although surgical outcomes have improved over time, these co-morbidities continue to contribute substantially to poor peri-operative mortality and morbidity outcomes. Peri-operative morbidity may have long-standing ramifications on neurodevelopment and overall health. Recognising the cardiovascular and non-cardiovascular risks associated with specific syndromic diagnoses will facilitate expectant management, early detection of clinical problems, and improved outcomes--for example, the development of syndrome-based protocols for peri-operative evaluation and prophylactic actions may improve outcomes for the more frequently encountered syndromes such as 22q11 deletion syndrome

    "Taste Strips” - A rapid, lateralized, gustatory bedside identification test based on impregnated filter papers

    Get PDF
    Objective : To elaborate normative values for a clinical psychophysical taste test ("Taste Strips”). Background : The "Taste Strips” are a psychophysical chemical taste test. So far, no definitive normative data had been published and only a fairly small sample size has been investigated. In light of this shortcoming for this easy, reliable and quick taste testing device, we attempted to provide normative values suitable for the clinical use. Setting : Normative value acquisition study, multicenter study. Methods : The investigation involved 537 participants reporting a normal sense of smell and taste (318 female, 219 male, mean age 44 years, age range 18-87 years). The taste test was based on spoonshaped filter paper strips ("Taste Strips”) impregnated with the four (sweet, sour, salty, and bitter) taste qualities in four different concentrations. The strips were placed on the left or right side of the anterior third of the extended tongue, resulting in a total of 32 trials. With their tongue still extended, patients had to identify the taste from a list of four descriptors, i. e., sweet, sour, salty, and bitter (multiple forcedchoice). To obtain an impression of overall gustatory function, the number of correctly identified tastes was summed up for a "taste score”. Results : Taste function decreased significantly with age. Women exhibited significantly higher taste scores than men which was true for all age groups. The taste score at the 10th percentile was selected as a cut-off value to distinguish normogeusia from hypogeusia. Results from a small series of patients with ageusia confirmed the clinical usefulness of the proposed normative values. Conclusion : The present data provide normative values for the "Taste Strips” based on over 500 subjects teste

    Clinically relevant variants identified in thoracic aortic aneurysm patients by research exome sequencing

    Get PDF
    Thoracic aortic aneurysm (TAA) is a genetically heterogeneous disease involving subclinical and progressive dilation of the thoracic aorta, which can lead to life-threatening complications such as dissection or rupture. Genetic testing is important for risk stratification and identification of at risk family members, and clinically available genetic testing panels have been expanding rapidly. However, when past testing results are normal, there is little evidence to guide decision-making about the indications and timing to pursue additional clinical genetic testing. Results from research based genetic testing can help inform this process. Here we present 10 TAA patients who have a family history of disease and who enrolled in research-based exome testing. Nine of these ten patients had previous clinical genetic testing that did not identify the cause of disease. We sought to determine the number of rare variants in 23 known TAA associated genes identified by research-based exome testing. In total, we found 10 rare variants in six patients. Likely pathogenic variants included a TGFB2 variant in one patient and a SMAD3 variant in another. These variants have been reported previously in individuals with similar phenotypes. Variants of uncertain significance of particular interest included novel variants in MYLK and MFAP5, which were identified in a third patient. In total, clinically reportable rare variants were found in 6/10 (60%) patients, with at least 2/10 (20%) patients having likely pathogenic variants identified. These data indicate that consideration of re-testing is important in TAA patients with previous negative or inconclusive results

    Enhanced exchange bias effects in a nanopatterned system consisting of two perpendicularly coupled ferromagnets

    Get PDF
    This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics.The effect of patterning on the shift of the hysteresis loop HE and coercivityHC in a system composed of two perpendicularly exchange-coupled ferromagnets (NiFe sputtered onto a [Pt/Co] multilayer) is investigated in long stripes and square dots. Setting the exchange bias coupling along the stripes results in a threefold increase of HE compared to the continuous films. HC increases dramatically when the coupling is set perpendicular to the stripes and also in the dots. Magnetic force microscopy studies and micromagnetic simulations suggest that differences in the number and orientation of the magnetic domains can account for the observed effects
    corecore