5 research outputs found

    The response of dual-species bacterial biofilm to 2% and 5% NaOCl mixed with etidronic acid:A laboratory real-time evaluation using optical coherence tomography

    Get PDF
    Aim: The addition of etidronic acid (HEDP) to sodium hypochlorite (NaOCl) could increase the antibiofilm potency of the irrigant, whilst maintaining the benefits of continuous chelation. Studies conducted so far have shown that mixing HEDP with NaOCl solutions of relatively low concentration does not compromise the antibiofilm efficacy of the irrigant. However, the working lifespan of NaOCl may decrease resulting in a reduction of its antibiofilm efficacy over time (efficiency). In this regard, continuous irrigant replenishment needs to be examined. This study investigated the response of a dual-species biofilm when challenged with 2% and 5% NaOCl mixed with HEDP for a prolonged timespan and under steady laminar flow. Methodology: Dual-species biofilms comprised of Streptococcus oralis J22 and Actinomyces naeslundii T14V-J1 were grown on human dentine discs in a constant depth film fermenter (CDFF) for 96 h. Biofilms were treated with 2% and 5% NaOCl, alone or mixed with HEDP. Irrigants were applied under steady laminar flow for 8 min. Biofilm response was evaluated by means of optical coherence tomography (OCT). Biofilm removal, biofilm disruption, rate of biofilm loss and disruption as well as bubble formation were assessed. One-way anova, Wilcoxon's signed-rank test and Kruskal–Wallis H test were performed for statistical analysis of the data. The level of significance was set at a ≤.05. Results: Increasing NaOCl concentration resulted in increased biofilm removal and disruption, higher rate of biofilm loss and disruption and increased bubble formation. Mixing HEDP with NaOCl caused a delay in the antibiofilm action of the latter, without compromising its antibiofilm efficacy. Conclusions: NaOCl concentration dictates the biofilm response irrespective of the presence of HEDP. The addition of HEDP resulted in a delay in the antibiofilm action of NaOCl. This delay affects the efficiency, but not the efficacy of the irrigant over time

    Study on the Influence of Refreshment/Activation Cycles and Irrigants on Mechanical Cleaning Efficiency During Ultrasonic Activation of the Irrigant\ud

    Get PDF
    Introduction\ud The aims of this study were to evaluate dentin debris removal from the root canal during ultrasonic activation of sodium hypochlorite (2% and 10%), carbonated water, and distilled water and to determine the influence of 3 ultrasonic refreshment/activation cycles of the irrigant by using the intermittent flush technique.\ud \ud Methods\ud Root canals with a standardized groove in 1 canal wall, which was filled with dentin debris, were irrigated ultrasonically. The irrigant was refreshed and ultrasonically activated 3 times for 20 seconds. The quantity of dentin debris after irrigation was determined after each refreshment/activation cycle.\ud \ud Results and Conclusions\ud Ultrasonic activation of the irrigant combined with the intermittent flush method produces a cumulative effect over 3 refreshment/activation cycles. Sodium hypochlorite as an irrigant is significantly more effective than carbonated water, which is significantly more effective than distilled water, in removing dentin debris from the root canal during ultrasonic activation\u

    Evaluation of Irrigant Flow in the Root Canal Using Different Needle Types by an Unsteady Computational Fluid Dynamics Model

    Get PDF
    Introduction:\ud The aim of this study was to evaluate the effect of needle tip design on the irrigant flow inside a prepared root canal during final irrigation with a syringe using a validated Computational Fluid Dynamics (CFD) model.\ud Methods:\ud A CFD model was created to simulate the irrigant flow inside a prepared root canal. Six different types of 30-G needles, three open-ended needles and three close-ended needles, were tested. Using this CFD model, the irrigant flow in the apical root canal was calculated and visualized. As a result, the streaming velocity, the apical pressure, and the shear stress on the root canal wall were evaluated. \ud Results:\ud The open-ended needles created a jet toward the apex and maximum irrigant replacement. Within this group, the notched needle appeared less efficient\ud in terms of irrigant replacement than the other two types. Within the close-ended group, the side-vented and double side-vented needle created a series of vortices and a less efficient irrigant replacement; the side-vented needle was slightly more efficient. The multi-vented needle created almost no flow apically to its tip, and wall shear stress was concentrated on a limited area, but the apical pressure was significantly lower than the other types. Conclusions:\ud The flow pattern of the open-ended needles was different from\ud the close-ended needles, resulting in more irrigant replacement in front of the open-ended needles but also higher apical pressure

    The Effect of Needle-insertion Depth on the Irrigant Flow in the Root Canal: Evaluation Using an Unsteady Computational Fluid Dynamics Model

    Get PDF
    Introduction\ud The aim of this study was to evaluate the effect of needle-insertion depth on the irrigant flow inside a prepared root canal during final irrigation with a syringe and two different needle types using a Computational Fluid Dynamics (CFD) model.\ud \ud Methods\ud A validated CFD model was used to simulate irrigant flow from either a side-vented or an open-ended flat 30-G needle positioned inside a prepared root canal (45 .06) at 1, 2, 3, 4, or 5 mm short of the working length (WL). Velocity, pressure, and shear stress in the root canal were evaluated.\ud \ud Results\ud The flow pattern in the apical part of the root canal was similar among different needle positions. Major differences were observed between the two needle types. The side-vented needle achieved irrigant replacement to the WL only at the 1-mm position, whereas the open-ended flat needle was able to achieve complete replacement even when positioned at 2 mm short of the WL. The maximum shear stress decreased as needles moved away from the WL. The flat needle led to higher mean pressure at the apical foramen. Both needles showed a similar gradual decrease in apical pressure as the distance from the WL increased.\ud \ud Conclusions\ud Needle-insertion depth was found to affect the extent of irrigant replacement, the shear stress on the canal wall, and the pressure at the apical foramen for both needle types\u