138 research outputs found

    Hospital utilisation and the costs associated with complications of ICD implantation in a contemporary primary prevention cohort

    Get PDF
    Introduction: Implantation of an implantable cardioverter defibrillator (ICD) is standard care for primary prevention of sudden cardiac death. However, ICD-related complications are increasing as the population of ICD recipients grows. Methods: ICD-related complications in a national DO-IT Registry cohort of 1442 primary prevention ICD patients were assessed in terms of additional use of hospital care resources and costs. Results: During a median follow-up of 28.7 months (IQR 25.2–33.7) one or more complications occurred in 13.5% of patients. A complication resulted in a surgical intervention in 53% of cases and required on average 3.65 additional hospital days. The additional hospital costs were €6,876 per complication or €8,110 per patient, to which clinical re-interventions and additional hospital days contributed most. Per category of complications, infections required most hospital utilisation and were most expensive at an average of €22,892. The mean costs were €5,800 for lead-related complications, €2,291 for pocket-related complications and €5,619 for complications due to other causes. We estimate that the total yearly incidence-based costs in the Netherlands for hospital management of ICD-related complications following ICD implantation for primary prevention are €2.7 million. Conclusion: Complications following ICD implantation are related to a substantial additional need for hospital resources. When performing cost-effectiveness analyses of ICD implantation, including the costs associated with complications, one should be aware that real-world complication rates may deviate from trial data. Considering the economic implications, strategies to reduce the incidence of complications are encouraged.</p

    Immunopathogenesis and Immune Modulation of Venezuelan Equine Encephalitis Virus-Induced Disease in the Mouse

    Get PDF
    AbstractThe course of Venezuelan equine encephalitis (VEE) disease in immunodeficient and immunologically normal mice was compared to define the role of the immune system in this disease process. Immunocompetent mice infected with VEE exhibited a biphasic illness characterized by an early self-limiting lymphoid phase and a fatal CNS phase. The lymphoid phase of the illness was characterized by extensive viral replication within spleen, thymus, Peyer's patches, and lymph nodes, was accompanied by a high-titered serum viremia, and resolved with the production of VEE-specific IgM class antibody at 72 h postinfection (p.i.). Immunocompetent animals survived an average of 6.8 ± 1.2 days before succumbing to fulminant encephalitis. In contrast, SCID mice infected with VEE showed a persistent replication of virus throughout all organs tested beginning at 24 h p.i. VEE-infected SCID mice exhibited a severe spongiform encephalopathy with 100% mortality and an average survival time of 8.9 ± 0.9 days. These studies indicated that the characteristic organ tropism of VEE in the mouse is due in large part to an early anti-viral state, the establishment of which is dependent upon the presence of an intact immune system. Finally, the CNS pathology in a VEE-infected mouse had a significant immunologic component. However, in contrast to other neurovirulent alphaviruses, VEE was directly cytopathic for the cells of the CNS, even in the absence of an immune response

    Dutch outcome in implantable cardioverter-defibrillator therapy (DO-IT)

    Get PDF
    Background Implantable cardioverter-defibrillators (ICDs) are widely used for the prevention of sudden cardiac death. At present, both clinical benefit and cost-effectiveness of ICD therapy in primary prevention patients are topics of discussion, as only a minority of these patients will eventually receive appropriate ICD therapy. Methods/design The DO-IT Registry is a nationwide prospective cohort with a target enrolment of 1,500 primary prevention ICD patients with reduced left ventricular function in a setting of structural heart disease. The primary outcome measures are death and appropriate ICD therapy for ventricular tachyarrhythmias. Secondary outcome measures are inappropriate ICD therapy, death of any cause, hospitalisation for ICD related complications and for cardiovascular reasons. As of December 2016, data on demographic, clinical, and ICD characteristics of 1,468 patients have been collected. Follow-up will continue up to 24 months after inclusion of the last patient. During follow-up, clinical and ICD data are collected based on the normal follow-up of these patients, assuming ICD interrogations take place every six months and clinical follow-up i

    Speckle observations with PISCO in Merate - V. Astrometric measurements of visual binaries in 2006

    Get PDF
    International audienceWe present relative astrometric measurements of visual binaries made during the first semester of 2006, with the Pupil Interferometry Speckle camera and COronagraph at the 102-cm Zeiss telescope of the Brera Astronomical Observatory, in Merate. Our sample contains orbital couples as well as binaries whose motion is still uncertain. We obtained 217 new measurements of 194 objects, with angular separations in the range 0.1-4.2arcsec, and an average accuracy of 0.01arcsec. The mean error on the position angles is 0.5°. About half of those angles could be determined without the usual 180° ambiguity by the application of triple-correlation techniques. We also present a revised orbit for ADS 277 for which the previously published orbit resulted in a large residual from our measurements

    The CIPRUS study, a nurse-led psychological treatment for patients with undifferentiated somatoform disorder in primary care: study protocol for a randomised controlled trial

    Get PDF
    Background: Up to a third of patients presenting medically unexplained physical symptoms in primary care may have a somatoform disorder, of which undifferentiated somatoform disorder (USD) is the most common type. Psychological interventions can reduce symptoms associated with USD and improve functioning. Previous research has either been conducted in secondary care or interventions have been provided by general practitioners (GPs) or psychologists in primary care. As efficiency and cost-effectiveness are imperative in primary care, it is important to investigate whether nurse-led interventions are effective as well. The aim of this study is to examine the effectiveness and cost-effectiveness of a short cognitive behavioural therapy (CBT)-based treatment for patients with USD provided by mental health nurse practitioners (MHNPs), compared to usual care. Methods: In a cluster randomised controlled trial, 212 adult patients with USD will be assigned to the intervention or care as usual. The intervention group will be offered a short, individual CBT-based treatment by the MHNP in addition to usual GP care. The main goal of the intervention is that patients become less impaired by their physical symptoms and cope with symptoms in a more effective way. In six sessions patients will receive problem-solving treatment. The primary outcome is improvement in physical functioning, measured by the physical component summary score of the RAND-36. Secondary outcomes include health-related quality of life measured by the separate subscales of the RAND-36, somatization (PHQ-15) and symptoms of depression and anxiety (HADS). Problem-solving skills, health anxiety, illness perceptions, coping, mastery and working alliance will be assessed as potential mediators. Assessments will be done at 0, 2, 4, 8 and 12 months. An economic evaluation will be conducted from a societal perspective with quality of life as the primary outcome measure assessed by the EQ-5D-5L. Health care, patient and lost productivity costs will be assessed with the Tic-P. Discussion: We expect that the intervention will improve physical functioning and is cost-effective compared to usual care. If so, more patients might successfully be treated in general practice, decreasing the number of referrals to specialist care. Trial registration: Dutch Trial Registry, identifier: NTR4686, Registered on 14 July 2014. © 2017 The Author(s)

    High-throughput isolation of circulating tumor DNA

    Get PDF
    The emerging interest in circulating tumor DNA (ctDNA) analyses for clinical trials has necessitated the development of a high-throughput method for fast, reproducible, and efficient isolation of ctDNA. Currently, the majority of ctDNA studies use the manual QIAamp (QA) platform to isolate DNA from blood. The purpose of this study was to compare two competing automated DNA isolation platforms [Maxwell (MX) and QIAsymphony (QS)] to the current ‘gold standard’ QA to facilitate high-throughput processing of samples in prospective trials. We obtained blood samples from healthy blood donors and metastatic cancer patients for plasma isolation. Total cell-free DNA (cfDNA) quantity was assessed by TERT quantitative PCR. Recovery efficiency was investigated by quantitative PCR analysis of spiked-in synthetic plant DNA. In addition, a b-actin fragmentation assay was performed to determine the amount of contamination by genomic DNA from lysed leukocytes. ctDNA quality was assessed by digital PCR for somatic variant detection. cfDNA quantity and recovery efficiency were lowest using the MX platform, whereas QA and QS showed a comparable performance. All platforms preferentially isolated small (136 bp) DNA fragments over large (420 and 2000 bp) DNA fragments. Detection of the number variant and wild-type molecules was most comparable between QA and QS. However, there was no significant difference in variant allele frequency comparing QS and MX to QA. In summary, we show that the QS platform has comparable performance to QA, the ‘gold standard’, and outperformed the MX platform depending on the readout used. We conclude that the QS can replace the more laborious QA platform, especially when high-throughput cfDNA isolation is needed

    Critical appraisal of technologies to assess electrical activity during atrial fibrillation: a position paper from the European Heart Rhythm Association and European Society of Cardiology Working Group on eCardiology in collaboration with the Heart Rhythm Society, Asia Pacific Heart Rhythm Society, Latin American Heart Rhythm Society and Computing in Cardiology

    Get PDF
    We aim to provide a critical appraisal of basic concepts underlying signal recording and processing technologies applied for (i) atrial fibrillation (AF) mapping to unravel AF mechanisms and/or identifying target sites for AF therapy and (ii) AF detection, to optimize usage of technologies, stimulate research aimed at closing knowledge gaps, and developing ideal AF recording and processing technologies. Recording and processing techniques for assessment of electrical activity during AF essential for diagnosis and guiding ablative therapy including body surface electrocardiograms (ECG) and endo- or epicardial electrograms (EGM) are evaluated. Discussion of (i) differences in uni-, bi-, and multi-polar (omnipolar/Laplacian) recording modes, (ii) impact of recording technologies on EGM morphology, (iii) global or local mapping using various types of EGM involving signal processing techniques including isochronal-, voltage- fractionation-, dipole density-, and rotor mapping, enabling derivation of parameters like atrial rate, entropy, conduction velocity/direction, (iv) value of epicardial and optical mapping, (v) AF detection by cardiac implantable electronic devices containing various detection algorithms applicable to stored EGMs, (vi) contribution of machine learning (ML) to further improvement of signals processing technologies. Recording and processing of EGM (or ECG) are the cornerstones of (body surface) mapping of AF. Currently available AF recording and processing technologies are mainly restricted to specific applications or have technological limitations. Improvements in AF mapping by obtaining highest fidelity source signals (e.g. catheter–electrode combinations) for signal processing (e.g. filtering, digitization, and noise elimination) is of utmost importance. Novel acquisition instruments (multi-polar catheters combined with improved physical modelling and ML techniques) will enable enhanced and automated interpretation of EGM recordings in the near future

    EIT Observations of the Extreme Ultraviolet Sun

    Full text link
    The Extreme Ultraviolet Imaging Telescope (EIT) on board the SOHO spacecraft has been operational since 2 January 1996. EIT observes the Sun over a 45 x 45 arc min field of view in four emission line groups: Feix, x, Fexii, Fexv, and Heii. A post-launch determination of the instrument flatfield, the instrument scattering function, and the instrument aging were necessary for the reduction and analysis of the data. The observed structures and their evolution in each of the four EUV bandpasses are characteristic of the peak emission temperature of the line(s) chosen for that bandpass. Reports on the initial results of a variety of analysis projects demonstrate the range of investigations now underway: EIT provides new observations of the corona in the temperature range of 1 to 2 MK. Temperature studies of the large-scale coronal features extend previous coronagraph work with low-noise temperature maps. Temperatures of radial, extended, plume-like structures in both the polar coronal hole and in a low latitude decaying active region were found to be cooler than the surrounding material. Active region loops were investigated in detail and found to be isothermal for the low loops but hottest at the loop tops for the large loops
    • …
    corecore