4 research outputs found

    Is sodium current present in human sinoatrial node cells?

    Get PDF
    Pacemaker activity of the sinoatrial node has been studied extensively in various animal species, but is virtually unexplored in man. As such, it is unknown whether the fast sodium current (INa) plays a role in the pacemaker activity of the human sinoatrial node. Recently, we had the unique opportunity to perform patch-clamp experiments on single pacemaker cells isolated from a human sinoatrial node. In 2 out of the 3 cells measured, we observed large inward currents with characteristics of INa. Although we were unable to analyze the current in detail, our findings provide strong evidence that INa is present in human sinoatrial node pacemaker cells, and that this INa is functionally available at potentials negative to -60 mV

    Is sodium current present in human sinoatrial node cells?

    No full text
    Pacemaker activity of the sinoatrial node has been studied extensively in various animal species, but is virtually unexplored in man. As such, it is unknown whether the fast sodium current (INa) plays a role in the pacemaker activity of the human sinoatrial node. Recently, we had the unique opportunity to perform patch-clamp experiments on single pacemaker cells isolated from a human sinoatrial node. In 2 out of the 3 cells measured, we observed large inward currents with characteristics of INa. Although we were unable to analyze the current in detail, our findings provide strong evidence that INa is present in human sinoatrial node pacemaker cells, and that this INa is functionally available at potentials negative to -60 mV.</p

    Glow-in-the-Dark Infectious Disease Diagnostics Using CRISPR-Cas9-Based Split Luciferase Complementation

    Get PDF
    Nucleic acid detection methods based on CRISPR and isothermal amplification techniques show great potential for point-of-care diagnostic applications. However, most current methods rely on fluorescent or lateral flow assay readout, requiring external excitation or postamplification reaction transfer. Here, we developed a bioluminescent nucleic acid sensor (LUNAS) platform in which target dsDNA is sequence-specifically detected by a pair of dCas9-based probes mediating split NanoLuc luciferase complementation. LUNAS is easily integrated with recombinase polymerase amplification (RPA), providing attomolar sensitivity in a rapid one-pot assay. A calibrator luciferase is included for a robust ratiometric readout, enabling real-time monitoring of the RPA reaction using a simple digital camera. We designed an RT-RPA-LUNAS assay that allows SARS-CoV-2 RNA detection without the need for cumbersome RNA isolation and demonstrated its diagnostic performance for COVID-19 patient nasopharyngeal swab samples. Detection of SARS-CoV-2 from samples with viral RNA loads of ∼200 cp/μL was achieved within ∼20 min, showing that RPA-LUNAS is attractive for point-of-care infectious disease testing
    corecore