2,491 research outputs found
Shift work is associated with 10-year incidence of atrial fibrillation in younger but not older individuals from the general population: results from the Tromsø Study
Objectives - Shift work is associated with myocardial infarction and stroke. We studied if shift work is also associated with incident atrial fibrillation (AF) and if this association differs, depending on sex and age.
Methods - We studied 22 339 participants (age 37.0±9.8 years, 49% women) with paid work from the third (1986–1987), fourth (1994–1995), fifth (2001) and sixth (2007–2008) surveys of the population-based Tromsø Study, Norway. Participants were followed up for ECG-confirmed AF through 2016. Shift work was assessed by questionnaire at each survey. We used unadjusted and multivariable-adjusted Cox regression models to study the association of shift work with 10-year incident AF and incident AF during extensive follow-up up to 31 years. Interactions with sex and age were tested in the multivariable model.
Results - Shift work was reported by 21% of participants at the first attended survey. There was an interaction between shift work and age for 10-year incident AF (p=0.069). When adjusted for AF risk factors, shift work was significantly associated with 10-year incident AF in participants
Conclusions - Shift work was associated with 10-year incident AF in individuals <40 years but not ≥40 years of age. Shift work was not associated with incident AF during extensive follow-up up to 31 years, and there were no sex differences.<p
Evaluation and comparison of simple empirical models for dead fuel moisture content
Background: The moisture content of litter and woody debris is a key determinant of fire potential and fire behaviour. Obtaining reliable estimates of the moisture content of dead fine fuels (i.e. 1-h and 10-h fuels) is therefore a critical requirement for effective fire management. Aims: We evaluated and compared the performance of five simple models for fuel moisture content. The models belong to two separate classes: (1) exponential functions of the vapour pressure deficit; and (2) affine functions of the (weighted) difference between air temperature and relative humidity. Methods: Model performance is assessed using error and correlation statistics, calculated using cross validation, over four empirical datasets. Key results: Overall, the best performing models were the relaxed and generalised models based on the weighted difference between temperature and relative humidity. Conclusions: Simple functions of the difference between air temperature and relative humidity can perform as well as, if not better than exponential functions of vapour pressure deficit. However, it is important to note the limitations of all these models when applied to fuels with moisture contents <10%. Implications: The moisture content of fine dead fuels and woody debris can be reliably estimated using simple models that are amenable to easy application
Predictive value of plasma galectin-3 levels in heart failure with reduced and preserved ejection fraction
Aims. Galectin-3 is an emerging biomarker which has been studied in relatively small heart failure (HF) cohorts with predominantly systolic HF. We studied the prognostic value of base-line galectin-3 in a large HF cohort, with preserved and reduced left ventricular ejection fraction (LVEF), and compared this to other biomarkers. Methods. We studied 592 HF patients who had been hospitalized for HF and were followed for 18 months. The primary end-point was a composite of all-cause mortality and HF hospitalization. Results. A doubling of galectin-3 levels was associated with a hazard ratio (HR) of 1.97 (1.62-2.42) for the primary outcome (P <0.001). After correction for age, gender, BNP, eGFR, and diabetes the HR was 1.38 (1.07-1.78; P = 0.015). Galectin-3 levels were correlated with higher IL-6 and CRP levels (P <0.002). Changes of galectin-3 levels after 6 months did not add prognostic information to the base-line value (n = 291); however, combining plasma galectin-3 and BNP levels increased prognostic value over either biomarker alone (ROC analysis, P <0.05). The predictive value of galectin-3 was stronger in patients with preserved LVEF (n = 114) compared to patients with reduced LVEF (P <0.001). Conclusions. Galectin-3 is an independent marker for outcome in HF and appears to be particularly useful in HF patients with preserved LVEF
Increased Adiposity, Dysregulated Glucose Metabolism and Systemic Inflammation in Galectin-3 KO Mice
PMCID: PMC3579848This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Early Mechanical Alterations in Phospholamban Mutation Carriers: Identifying Subclinical Disease Before Onset of Symptoms
OBJECTIVES: This study aimed to explore echocardiographic characteristics of phospholamban (PLN) p.Arg14del mutation carriers to investigate whether structural and/or functional abnormalities could be identified before onset of symptoms. BACKGROUND: Carriers of the genetic PLN p.Arg14del mutation may develop arrhythmogenic and/or dilated cardiomyopathy. Overt disease is preceded by a pre-symptomatic phase of variable length in which disease expression seems to be absent. METHODS: PLN p.Arg14del mutation carriers with an available echocardiogram were included. Mutation carriers were classified as pre-symptomatic if they had no history of ventricular arrhythmias (VAs), a premature ventricular complex count of <500/24 h, and a left ventricular (LV) ejection fraction of ≥45%. In addition, we included 70 control subjects with similar age and sex distribution as the pre-symptomatic mutation carriers. Comprehensive echocardiographic analysis (including deformation imaging) was performed. RESULTS: The final study population consisted of 281 PLN p.Arg14del mutation carriers, 139 of whom were classified as pre-symptomatic. In comparison to control subjects, pre-symptomatic mutation carriers had lower global longitudinal strain and higher LV mechanical dispersion (both p < 0.001). In addition, post-systolic shortening (PSS) in the LV apex was observed in 43 pre-symptomatic mutation carriers (31%) and in none of the control subjects. During a median follow-up of 3.2 years (interquartile range: 2.1 to 5.6 years) in 104 pre-symptomatic mutation carriers, nonsustained VA occurred in 13 (13%). Presence of apical PSS was the strongest echocardiographic predictor of VA (multivariable hazards ratio: 5.11; 95% confidence interval [CI]: 1.37 to 19.08; p = 0.015), which resulted in a negative predictive value of 96% (95% CI: 89% to 98%) and a positive predictive value of 29% (95% CI: 21% to 40%). CONCLUSIONS: Global and regional LV mechanical alterations in PLN p.Arg14del mutation carriers precede arrhythmic symptoms and overt structural disease. Pre-symptomatic mutation carriers with normal deformation patterns in the apex are at low risk of developing VA within 3 years, whereas mutation carriers with apical PSS appear to be at higher risk
Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study.
BACKGROUND: Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study was performed to compare inhalation parameters with empty versions of the two devices, and to investigate the effects of enhanced training designed to encourage faster inhalation. METHODS: This randomised, open-label, cross-over study included children with asthma (n = 23), adolescents with asthma (n = 27), adults with asthma (n = 50), adults with COPD (n = 50) and healthy adult volunteers (n = 50). Inhalation manoeuvres were recorded with each device after training with the patient information leaflet (PIL) and after enhanced training using an In-Check Dial device. RESULTS: After PIL training, peak inspiratory flow (PIF), maximum change in pressure (∆P) and the inhalation volume (IV) were significantly higher with Spiromax than with the Turbuhaler device (p values were at least <0.05 in all patient groups). After enhanced training, numerically or significantly higher values for PIF, ∆P, IV and acceleration remained with Spiromax versus Turbuhaler, except for ∆P in COPD patients. After PIL training, one adult asthma patient and one COPD patient inhaled <30 L/min through the Spiromax compared to one adult asthma patient and five COPD patients with the Turbuhaler. All patients achieved PIF values of at least 30 L/min after enhanced training. CONCLUSIONS: The two inhalers have similar resistance so inhalation flows and pressure changes would be expected to be similar. The higher flow-related values noted for Spiromax versus Turbuhaler after PIL training suggest that Spiromax might have human factor advantages in real-world use. After enhanced training, the flow-related differences between devices persisted; increased flow rates were achieved with both devices, and all patients achieved the minimal flow required for adequate drug delivery. Enhanced training could be useful, especially in COPD patients
- …