35 research outputs found

    A process-reliable tailoring of subsurface properties during cryogenic turning using dynamic process control

    Get PDF
    Considering the current demands for resource conservation and energy efficiency, innovative machining concepts and increased process reliability have a significant role to play. A combination of martensitic hardening of the subsurface and near-net-shape manufacturing represent a great potential to produce components with wear-resistant subsurfaces in an energy- and time-saving way. Within the scope of the present study, the influence of cryogenic machining of metastable austenitic steel on the martensitic transformation and surface quality was investigated. Different cooling strategies were used. A soft sensor based on eddy current in-process measurements was used to determine and subsequently affect the martensitic transformation of the subsurface. The feed rate and component temperature were identified as significant factors influencing the martensitic transformation. However, a high feed rate leads to an increase in surface roughness, and thus to a reduction in component quality. For this reason, a roughing process for achieving maximum martensitic transformation was carried out first in the present study and then a reduction in the surface roughness by maintaining the martensitic subsurface content was aimed for by a subsequent finishing process. With the knowledge generated, a dynamic process control was finally set up for designing the turning process of a required subsurface condition and surface quality

    In-Orbit Performance of the GRACE Follow-on Laser Ranging Interferometer

    Get PDF
    The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately 220 km. Autonomous controls that lock the laser frequency to a cavity reference and establish the 5 degrees of freedom two-way laser link between remote spacecraft succeeded on the first attempt. Active beam pointing based on differential wave front sensing compensates spacecraft attitude fluctuations. The LRI has operated continuously without breaks in phase tracking for more than 50 days, and has shown biased range measurements similar to the primary ranging instrument based on microwaves, but with much less noise at a level of 1 nm/Hz at Fourier frequencies above 100 mHz. © 2019 authors. Published by the American Physical Society

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Status of the next generation CMOS-TDI detector for high-resolution imaging

    No full text
    The Institute of Optical Sensor Systems (OS) at the Robotics and Mechatronics Center of the German Aerospace Center (DLR) has more than 35 years of experience with high-resolution imaging technology. This paper shows the institutes scientific results of the next generation of CMOS detector design in a TDI (Time Delay and Integration) architecture. This project includes the technological design of future high or multispectral resolution space-borne instruments and the possibility of higher integration. First results where published by Eckardt, et al. (1 ) 2013 and (2 ) 2014. DLR OS and the Fraunhofer Institute for Microelectronic Circuits and Systems in Duisburg were driving the technology of new detectors for future high resolution projects and hybridization capability in order to keep pace with the ambitious scientific and user requirements. In combination with the engineering research, the current generation of space borne sensor systems is focusing on VIS/NIR high spectral resolution to meet the requirements on earth and planetary observation systems. The combination of large swath and high-spectral resolution with intelligent synchronization control, fast-readout ADC chains and new focal-plane concepts open the door to new remote-sensing and smart deep-space instruments. The paper gives an overview over the DLR detector development and verification program on FPA level. New control possibilities for CMOS-TDI NG detectors in synchronization control mode, and key parameters like linearity, PTC, cross talk and control effort will be discussed in detail

    Phase stability of photoreceivers in intersatellite laser interferometers

    Get PDF
    A photoreceiver (PR) is required for the opto-electrical conversion of signals in intersatellite laser interferometers. Noise sources that originate or couple in the PR reduce the system carrier-to-noise-density, which is often represented by its phase noise density. In this work, we analyze the common noise sources in a PR used for space-based interferometry. Additionally, we present the results from the characterization of the PRs in GRACE-FO, a mission which will pioneer intersatellite laser interferometry. The estimated phase noise is shot-noise limited at 10-4 rad/Hz112 down to 10-2 Hz, almost 4 orders of magnitude below the instrument top level requirement (0.5 rad/Hz112). Below 10-2 Hz, the PR finite phase response noise dominates but the levels still comply with the instrument requirement. The sub-mHz noise levels and the PR electronic noise have been identified as key design factors for the LISA PR

    DESIS - DLR Earth Sensing Imaging Spectrometer

    No full text
    Space-based hyperspectral instruments are used in many applications requiring identification of materials or helping to monitor the environment. Although there are lots of useful applications, the amount of space born data is limited. The DLR Earth Sensing Imaging Spectrometer (DESIS) is a new space-based hyperspectral instrument developed by DLR and operated under collaboration between the German Aerospace Center (DLR) and Teledyne Brown Engineering (TBE). The primary goal of DESIS is to measure and analyze quantitative diagnostic parameters describing key processes on the Earth sur-face. This goal can be reached with the instrument parameters of 235 spectral bands from 400 nm to 1000 nm and a GSD of 30 m. DESIS was installed on the International Space Station on the MUSES platform in August 2018 and is providing hyperspectral Earth Observation in the wavelength range from visible to near-infrared with high resolution and near global coverage. This contribution presents the de-sign of the compact instrument. With its interface constraints it would be also suitable for small satellite platforms

    The Instrument Design of the DLR Earth Sensing Imaging Spectrometer (DESIS)

    Get PDF
    Whether for identification and characterization of materials or for monitoring of the environment, space-based hyperspectral instruments are very useful. Hyperspectral instruments measure several dozens up to hundreds of spectral bands. These data help to reconstruct the spectral properties like reflectance or emission of Earth surface or the absorption of the atmosphere, and to identify constituents on land, water, and in the atmosphere. There are a lot of possible applications, from vegetation and water quality up to greenhouse gas monitoring. But the actual number of hyperspectral space-based missions or hyperspectral space-based data is limited. This will be changed in the next years by different missions. The German Aerospace Center (DLR) Earth Sensing Imaging Spectrometer (DESIS) is one of the new currently existing space-based hyperspectral instruments, launched in 2018 and ready to reduce the gap of space-born hyperspectral data. The instrument is operating onboard the International Space Station, using the Multi-User System for Earth Sensing (MUSES) platform. The instrument has 235 spectral bands in the wavelength range from visible (400 nm) to near-infrared (1000 nm), which results in a 2.5 nm spectral sampling distance and a ground sampling distance of 30 m from 400 km orbit of the International Space Station. In this article, the design of the instrument will be described
    corecore