389 research outputs found
Performance Modeling of Fresnel-Based CPV Systems: Effects of Deformations under Real Operation Conditions
Getting a lower energy cost has always been a challenge for concentrated photovoltaic. The FK concentrator enhances the performance (efficiency, acceptance angle and manufacturing tolerances) of the conventional CPV system based on a Fresnel primary stage and a secondary lens, while keeping its simplicity and potentially lowâcost manufacturing. At the same time FâXTP (Fresnel lens+reflective prism), at the first glance has better cost potential but significantly higher sensitivity to manufacturing errors. This work presents comparison of these two approaches applied to two main technologies of Fresnel lens production (PMMA and Silicone on Glass) and effect of standard deformations that occur under real operation condition
Current methods for development of rapid reviews about diagnostic tests: an international survey
Background
Rapid reviews (RRs) have emerged as an efficient alternative to time-consuming systematic reviewsâthey can help meet the demand for accelerated evidence synthesis to inform decision-making in healthcare. The synthesis of diagnostic evidence has important methodological challenges. Here, we performed an international survey to identify the current practice of producing RRs for diagnostic tests.
Methods
We developed and administered an online survey inviting institutions that perform RRs of diagnostic tests from all over the world.
Results
All participants (Nâ=â25) reported the implementation of one or more methods to define the scope of the RR; however, only one strategy (defining a structured question) was used by â„90% of participants. All participants used at least one methodological shortcut including the use of a previous review as a starting point (92%) and the use of limits on the search (96%). Parallelization and automation of review tasks were not extensively used (48 and 20%, respectively).
Conclusion
Our survey indicates a greater use of shortcuts and limits for conducting diagnostic test RRs versus the results of a recent scoping review analyzing published RRs. Several shortcuts are used without knowing how their implementation affects the results of the evidence synthesis in the setting of diagnostic test reviews. Thus, a structured evaluation of the challenges and implications of the adoption of these RR methods is warranted
Challenges of rapid reviews for diagnostic test accuracy questions: a protocol for an international survey and expert consultation
Background: Assessment of diagnostic tests, broadly defined as any element that aids in the collection of additional information for further clarification of a patientâs health status, has increasingly become a critical issue in health policy and decision-making. Diagnostic evidence, including the accuracy of a medical test for a target condition, is commonly appraised using standard systematic review methodology. Owing to the considerable time and resources required to conduct these, rapid reviews have emerged as a pragmatic alternative by tailoring methods according to the decision makerâs circumstances. However, it is not known if streamlining methodological aspects has an impact on the validity of evidence synthesis. Furthermore, due to the particular nature and complexity of the appraisal of diagnostic accuracy, there is need for detailed guidance on how to conduct rapid reviews of diagnostic tests. In this study, we aim to identify the methods currently used by rapid review developers to synthesize evidence on diagnostic test accuracy, as well as to analyze potential shortcomings and challenges related to these methods. Methods: We will carry out a two-fold approach: (1) an international survey of professionals working in organizations that develop rapid reviews of diagnostic tests, in terms of the methods and resources used by these agencies when conducting rapid reviews, and (2) semi-structured interviews with senior-level individuals to further explore and validate the findings from the survey and to identify challenges in conducting rapid reviews. We will use STATA 15.0 for quantitative analyses and framework analysis for qualitative analyses. We will ensure protection of data during all stages.
Discussion: The main result of this research will be a map of methods and resources currently used for conducting rapid reviews of diagnostic test accuracy, as well as methodological shortcomings and potential solutions in diagnostic knowledge synthesis that require further research
Non-monotonic variation with salt concentration of the second virial coefficient in protein solutions
The osmotic virial coefficient of globular protein solutions is
calculated as a function of added salt concentration at fixed pH by computer
simulations of the ``primitive model''. The salt and counter-ions as well as a
discrete charge pattern on the protein surface are explicitly incorporated. For
parameters roughly corresponding to lysozyme, we find that first
decreases with added salt concentration up to a threshold concentration, then
increases to a maximum, and then decreases again upon further raising the ionic
strength. Our studies demonstrate that the existence of a discrete charge
pattern on the protein surface profoundly influences the effective interactions
and that non-linear Poisson Boltzmann and Derjaguin-Landau-Verwey-Overbeek
(DLVO) theory fail for large ionic strength. The observed non-monotonicity of
is compared to experiments. Implications for protein crystallization are
discussed.Comment: 43 pages, including 17 figure
Observation of hard scattering in photoproduction events with a large rapidity gap at HERA
Events with a large rapidity gap and total transverse energy greater than 5
GeV have been observed in quasi-real photoproduction at HERA with the ZEUS
detector. The distribution of these events as a function of the
centre of mass energy is consistent with diffractive scattering. For total
transverse energies above 12 GeV, the hadronic final states show predominantly
a two-jet structure with each jet having a transverse energy greater than 4
GeV. For the two-jet events, little energy flow is found outside the jets. This
observation is consistent with the hard scattering of a quasi-real photon with
a colourless object in the proton.Comment: 19 pages, latex, 4 figures appended as uuencoded fil
Anisotropic flow of charged hadrons, pions and (anti-)protons measured at high transverse momentum in Pb-Pb collisions at TeV
The elliptic, , triangular, , and quadrangular, , azimuthal
anisotropic flow coefficients are measured for unidentified charged particles,
pions and (anti-)protons in Pb-Pb collisions at TeV
with the ALICE detector at the Large Hadron Collider. Results obtained with the
event plane and four-particle cumulant methods are reported for the
pseudo-rapidity range at different collision centralities and as a
function of transverse momentum, , out to GeV/.
The observed non-zero elliptic and triangular flow depends only weakly on
transverse momentum for GeV/. The small dependence
of the difference between elliptic flow results obtained from the event plane
and four-particle cumulant methods suggests a common origin of flow
fluctuations up to GeV/. The magnitude of the (anti-)proton
elliptic and triangular flow is larger than that of pions out to at least
GeV/ indicating that the particle type dependence persists out
to high .Comment: 16 pages, 5 captioned figures, authors from page 11, published
version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/186
Centrality dependence of charged particle production at large transverse momentum in Pb-Pb collisions at TeV
The inclusive transverse momentum () distributions of primary
charged particles are measured in the pseudo-rapidity range as a
function of event centrality in Pb-Pb collisions at
TeV with ALICE at the LHC. The data are presented in the range
GeV/ for nine centrality intervals from 70-80% to 0-5%.
The Pb-Pb spectra are presented in terms of the nuclear modification factor
using a pp reference spectrum measured at the same collision
energy. We observe that the suppression of high- particles strongly
depends on event centrality. In central collisions (0-5%) the yield is most
suppressed with at -7 GeV/. Above
GeV/, there is a significant rise in the nuclear modification
factor, which reaches for GeV/. In
peripheral collisions (70-80%), the suppression is weaker with almost independently of . The measured nuclear
modification factors are compared to other measurements and model calculations.Comment: 17 pages, 4 captioned figures, 2 tables, authors from page 12,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/284
Suppression of charged particle production at large transverse momentum in central Pb-Pb collisions at TeV
Inclusive transverse momentum spectra of primary charged particles in Pb-Pb
collisions at = 2.76 TeV have been measured by the ALICE
Collaboration at the LHC. The data are presented for central and peripheral
collisions, corresponding to 0-5% and 70-80% of the hadronic Pb-Pb cross
section. The measured charged particle spectra in and GeV/ are compared to the expectation in pp collisions at the same
, scaled by the number of underlying nucleon-nucleon
collisions. The comparison is expressed in terms of the nuclear modification
factor . The result indicates only weak medium effects ( 0.7) in peripheral collisions. In central collisions,
reaches a minimum of about 0.14 at -7GeV/ and increases
significantly at larger . The measured suppression of high- particles is stronger than that observed at lower collision energies,
indicating that a very dense medium is formed in central Pb-Pb collisions at
the LHC.Comment: 15 pages, 5 captioned figures, 3 tables, authors from page 10,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/98
Two-pion Bose-Einstein correlations in central Pb-Pb collisions at = 2.76 TeV
The first measurement of two-pion Bose-Einstein correlations in central Pb-Pb
collisions at TeV at the Large Hadron Collider is
presented. We observe a growing trend with energy now not only for the
longitudinal and the outward but also for the sideward pion source radius. The
pion homogeneity volume and the decoupling time are significantly larger than
those measured at RHIC.Comment: 17 pages, 5 captioned figures, 1 table, authors from page 12,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/388
- âŠ