156 research outputs found
Optimization of the seed medium of Lactobacillus casei GJ00412 isolated from soy whey
Soy whey (SW) is generated as a process waste during soy isolate protein preparation. SW has low content of soluble sugar and high content of oligosaccharide, which is suitable for the growth of lactic acid bacteria (LAB). In this study, a strain of Lactobacillus casei GJ00412 (by 16S rRNA genesequencing and identification) was isolated from soy whey. In order to reduce the cost of culture medium, improve its biomass, and facilitate the next utilization, Response surface methodology (RSM) was employed to optimize the composition of seed medium of Lactobacillus casei By Plackett-Burman design, sucrose, yeast power, MgSO4, Tween80 and pH value were found to have significant effects on biomass, and were further analyzed by Box-behnken design, an application of response surface. The optimized medium was as follows (w/v): 2.5% sucrose, 1.8% soy peptone, 0.4% yeast powder, 0.08% MgSO4, 0.04% MnSO4, 0.08% Tween80, pH 7.17. The results showed that the cost of the optimized medium was decreased and the biomass of Lactobacillus casei has no significant difference when compared with MRS medium
Application potential of grain and oil processing by-products in research of microbial-oriented food
Hundreds of millions of bacteria adhere to human intestinal epithelium,which are the participants of human health and physiological functions,and also an important target covered by the concept of comprehensive health.So far,the supplementation of prebiotics remainsare still one of the effective means to regulate intestinal microbiota and promote the growth of beneficial microbes.The by-productsof grain and oil processing are abundant in variety and yield,and many of them can be utilized by human intestinal microbiota,which are one of the sources of high-quality prebiotics,and also the important material basis and raw material source in the development of “microbial-oriented food”
The LAMOST Complete Spectroscopic Survey of Pointing Area (LaCoSSPAr) in the Southern Galactic Cap I. The Spectroscopic Redshift Catalog
We present a spectroscopic redshift catalog from the LAMOST Complete
Spectroscopic Survey of Pointing Area (LaCoSSPAr) in the Southern Galactic Cap
(SGC), which is designed to observe all sources (Galactic and extra-galactic)
by using repeating observations with a limiting magnitude of in
two fields. The project is mainly focusing on the completeness of
LAMOST ExtraGAlactic Surveys (LEGAS) in the SGC, the deficiencies of source
selection methods and the basic performance parameters of LAMOST telescope. In
both fields, more than 95% of galaxies have been observed. A post-processing
has been applied to LAMOST 1D spectrum to remove the majority of remaining sky
background residuals. More than 10,000 spectra have been visually inspected to
measure the redshift by using combinations of different emission/absorption
features with uncertainty of . In total, there are 1528
redshifts (623 absorption and 905 emission line galaxies) in Field A and 1570
redshifts (569 absorption and 1001 emission line galaxies) in Field B have been
measured. The results show that it is possible to derive redshift from low SNR
galaxies with our post-processing and visual inspection. Our analysis also
indicates that up to 1/4 of the input targets for a typical extra-galactic
spectroscopic survey might be unreliable. The multi-wavelength data analysis
shows that the majority of mid-infrared-detected absorption (91.3%) and
emission line galaxies (93.3%) can be well separated by an empirical criterion
of . Meanwhile, a fainter sequence paralleled to the main population
of galaxies has been witnessed both in / and /
diagrams, which could be the population of luminous dwarf galaxies but
contaminated by the edge-on/highly inclined galaxies ().Comment: 19 pages, 14 figures, 2 MRT, accepted by ApJ
Retinal microvascular and microstructural alterations in the diagnosis of meibomian gland dysfunction in severely obese population: a new approach
AIM: To study retinal microvascular and microstructural alterations in meibomian gland dysfunction (MGD) in severely obese population using optical coherence tomography angiography (OCTA). METHODS: Twelve MGD patients with severely obese population (PAT group; 24 eyes) and 12 healthy controls (HC group; 24 eyes) were recruited. OCTA images were segmented into five [superior (S), nasal (N), inferior (I), temporal (T), and central foveal (C)] or nine [inner superior (IS), outer superior (OS), inner nasal (IN), outer nasal (ON), inner inferior (II), outer inferior (OI), inner temporal (IT), outer temporal (OT), and C] subregions. The superficial vessel density (SVD), retinal thickness (RT), foveal avascular zone (FAZ) parameters, and retinal volume were measured. RESULTS: Visual acuity was significantly different between two groups (0.8±0.17 in PAT group vs 0.2±0.06 in HC group). SVD was significantly lower in PATs in N, T, OS, IN, OT, and ON. The area under the receiver operating characteristic curve (AUC) for T was 0.961 [95% confidence interval (CI): 0.908 to 1.000], for OS was 0.962 (95%CI: 0.915 to 1.000). RT was significantly lower in PATs in IS, OS, OI, OT, ON, IT, IN, and II. AUC for OT was 0.935 (95%CI: 0.870 to 0.999), for IS was 0.915 (95% CI: 0.838 to 0.992). Angiography results showed significantly lower area and perimeter of FAZ, SVD of the inner retina and both retinal volume and the average volume thickness in the PAT group. CONCLUSION: Vision may be affected in patients with MGD due to changes in retinal microvessels and microstructures. These changes detected by OCTA may be a potential marker for diagnosing MGD in severe obesity
Seoul Virus and Hantavirus Disease, Shenyang, People’s Republic of China
This outbreak was caused by the virus circulating in local wild rats through infection of laboratory rats
A prospective and consecutive study assessing short-term clinical and radiographic outcomes of Chinese domestically manufactured 3D printing trabecular titanium acetabular cup for primary total hip arthroplasty: evaluation of 236 cases
PurposeWe prospectively evaluate the short-term clinical and radiographic outcomes of the only Chinese domestically produced trabecular titanium acetabular cup(3D ACT™ cup) in primary total hip arthroplasty (THA), aiming to provide evidence-based support for its clinical application.MethodsA total of 236 patients, who underwent primary THA using 3D ACT™ cup in the Department of Joint Surgery at our hospital between January 2017 and June 2019, were included in this study. General patient data, imaging information, functional scores, and complications were collected to evaluate the early clinical efficacy.ResultsAll patients were followed up for 33–52 months, with an average of (42.2 ± 9.2) months. At the last follow-up, the preoperative HHS score increased significantly from 43.7 ± 6.8 to 85.6 ± 9.3 points (P < 0.01). Similarly, the preoperative WOMAC scores showed significant improvement from 59.2 ± 5.8 to 13.1 ± 3.5 points (P < 0.01). 92.3% of the patients expressed satisfaction or high satisfaction with the clinical outcome. Furthermore, 87.7% of the acetabular cups were positioned within the Lewinnek safe zone, achieving successful reconstruction of the acetabular rotation center. The cup survival rate at the last follow-up was 100%.ConclusionsThe utilization of the only Chinese domestically manufactured 3D printing trabecular titanium acetabular cup in primary THA demonstrated favorable short-term clinical and radiographic outcomes. The acetabular cup exhibits excellent initial stability, high survival rate, and favorable osseointegration, leading to a significant enhancement in pain relief and functional improvement. In the future, larger sample sizes and multicenter prospective randomized controlled trials will be required to validate the long-term safety and effectiveness of this 3D ACT™ cup
A simulation study on the measurement of D0-D0bar mixing parameter y at BES-III
We established a method on measuring the \dzdzb mixing parameter for
BESIII experiment at the BEPCII collider. In this method, the doubly
tagged events, with one decays to
CP-eigenstates and the other decays semileptonically, are used to
reconstruct the signals. Since this analysis requires good separation,
a likelihood approach, which combines the , time of flight and the
electromagnetic shower detectors information, is used for particle
identification. We estimate the sensitivity of the measurement of to be
0.007 based on a fully simulated MC sample.Comment: 6 pages, 7 figure
Aggregation-Induced Emission (AIE), Life and Health
Light has profoundly impacted modern medicine and healthcare, with numerous luminescent agents and imaging techniques currently being used to assess health and treat diseases. As an emerging concept in luminescence, aggregation-induced emission (AIE) has shown great potential in biological applications due to its advantages in terms of brightness, biocompatibility, photostability, and positive correlation with concentration. This review provides a comprehensive summary of AIE luminogens applied in imaging of biological structure and dynamic physiological processes, disease diagnosis and treatment, and detection and monitoring of specific analytes, followed by representative works. Discussions on critical issues and perspectives on future directions are also included. This review aims to stimulate the interest of researchers from different fields, including chemistry, biology, materials science, medicine, etc., thus promoting the development of AIE in the fields of life and health
- …