22 research outputs found

    Short acquisition time PET quantification using MRI-based pharmacokinetic parameter synthesis

    Get PDF
    Positron Emission Tomography (PET) with pharmacokinetic (PK) modelling is a quantitative molecular imaging technique, however the long data acquisition time is prohibitive in clinical practice. An approach has been proposed to incorporate blood flow information from Arterial Spin Labelling (ASL) Magnetic Resonance Imaging (MRI) into PET PK modelling to reduce the acquisition time. This requires the conversion of cerebral blood flow (CBF) maps, measured by ASL, into the relative tracer delivery parameter (R 1 ) used in the PET PK model. This was performed regionally using linear regression between population R 1 and ASL values. In this paper we propose a novel technique to synthesise R 1 maps from ASL data using a database with both R 1 and CBF maps. The local similarity between the candidate ASL image and those in the database is used to weight the propagation of R 1 values to obtain the optimal patient specific R 1 map. Structural MRI data is also included to provide information within common regions of artefact in ASL data. This methodology is compared to the linear regression technique using leave one out analysis on 32 subjects. The proposed method significantly improves regional R 1 estimation (p < 0.001), reducing the error in the pharmacokinetic modelling. Furthermore, it allows this technique to be extended to a voxel level, increasing the clinical utility of the images

    ASL-incorporated pharmacokinetic modelling of PET data with reduced acquisition time:Application to amyloid imaging

    Get PDF
    Pharmacokinetic analysis of Positron Emission Tomography (PET) data typically requires at least one hour of image acquisition, which poses a great disadvantage in clinical practice. In this work, we propose a novel approach for pharmacokinetic modelling with significantly reduced PET acquisition time, by incorporating the blood flow information from simultaneously acquired arterial spin labelling (ASL) magnetic resonance imaging (MRI). A relationship is established between blood flow, measured by ASL, and the transfer rate constant from plasma to tissue of the PET tracer, leading to modified PET kinetic models with ASL-derived flow information. Evaluation on clinical amyloid imaging data from an Alzheimer’s disease (AD) study shows that the proposed approach with the simplified reference tissue model can achieve amyloid burden estimation from 30 min [18F]florbetapir PET data and 5 min simultaneous ASL MR data, which is comparable with the estimation from 60 min PET data (mean error=−0.03). Conversely, standardised uptake value ratio (SUVR), the alternative measure from the data showed a positive bias in areas of higher amyloid burden (mean error=0.07)
    corecore